Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos

Sumit K. Banchhor, Narendra D. Londhe, Tadashi Araki, Luca Saba, Petia Radeva, John R. Laird, Jasjit S. Suri, Fellow AIMBE

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Background Accurate and fast quantitative assessment of calcium volume is required during the planning of percutaneous coronary interventions procedures. Low resolution in intravascular ultrasound (IVUS) coronary videos poses a threat to calcium detection causing over-estimation in volume measurement. We introduce a correction block that counter-balances the bias introduced during the calcium detection process. Method Nineteen patients image dataset (around 40,090 frames), IRB approved, were collected using 40 MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5 mm/sec). A new set of 20 generalized and well-balanced systems each consisting of three stages: (i) calcium detection, (ii) calibration and (iii) measurement, while ensuring accuracy of four soft classifiers (Threshold, FCM, K-means and HMRF) and workflow speed using five multiresolution techniques (bilinear, bicubic, wavelet, Lanczos, Gaussian Pyramid) were designed. Results of the three calcium detection methods were benchmarked against the Threshold-based method. Results All 20 well-balanced systems with calibration block show superior performance. Using calibration block, FCM versus Threshold-based method shows the highest cross-correlation 0.99 (P<0.0001), Jaccard index 0.984±0.013 (P<0.0001), and Dice similarity 0.992±0.007 (P<0.0001). The corresponding area under the curve for four calcium detection techniques is: 1.0, 1.0, 0.97 and 0.93, respectively. The mean overall performance improvement is 38.54% and when adapting calibration block. The mean workflow speed improvement is 62.14% when adapting multiresolution paradigm. Three clinical tests shows consistency, reliability, and stability of our well-balanced system. Conclusions A well-balanced system with a combination of Threshold embedded with Lanczos multiresolution was optimal and can be useable in clinical settings.

Original languageEnglish (US)
Pages (from-to)168-181
Number of pages14
JournalComputers in Biology and Medicine
Volume84
DOIs
StatePublished - May 1 2017

Fingerprint

Volume measurement
Calcium
Ultrasonics
Calibration
Workflow
Catheters
Research Ethics Committees
Percutaneous Coronary Intervention
Area Under Curve
Classifiers
Planning

Keywords

  • Calibration
  • Classification
  • Coronary calcium volume
  • Low-resolution IVUS
  • Multiresolution
  • Speed

ASJC Scopus subject areas

  • Computer Science Applications
  • Health Informatics

Cite this

Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos. / Banchhor, Sumit K.; Londhe, Narendra D.; Araki, Tadashi; Saba, Luca; Radeva, Petia; Laird, John R.; Suri, Jasjit S.; Fellow AIMBE.

In: Computers in Biology and Medicine, Vol. 84, 01.05.2017, p. 168-181.

Research output: Contribution to journalArticle

Banchhor, Sumit K. ; Londhe, Narendra D. ; Araki, Tadashi ; Saba, Luca ; Radeva, Petia ; Laird, John R. ; Suri, Jasjit S. ; Fellow AIMBE. / Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos. In: Computers in Biology and Medicine. 2017 ; Vol. 84. pp. 168-181.
@article{d1884786e9a84aa69a209c4618c69db0,
title = "Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos",
abstract = "Background Accurate and fast quantitative assessment of calcium volume is required during the planning of percutaneous coronary interventions procedures. Low resolution in intravascular ultrasound (IVUS) coronary videos poses a threat to calcium detection causing over-estimation in volume measurement. We introduce a correction block that counter-balances the bias introduced during the calcium detection process. Method Nineteen patients image dataset (around 40,090 frames), IRB approved, were collected using 40 MHz IVUS catheter (Atlantis{\circledR} SR Pro, Boston Scientific{\circledR}, pullback speed of 0.5 mm/sec). A new set of 20 generalized and well-balanced systems each consisting of three stages: (i) calcium detection, (ii) calibration and (iii) measurement, while ensuring accuracy of four soft classifiers (Threshold, FCM, K-means and HMRF) and workflow speed using five multiresolution techniques (bilinear, bicubic, wavelet, Lanczos, Gaussian Pyramid) were designed. Results of the three calcium detection methods were benchmarked against the Threshold-based method. Results All 20 well-balanced systems with calibration block show superior performance. Using calibration block, FCM versus Threshold-based method shows the highest cross-correlation 0.99 (P<0.0001), Jaccard index 0.984±0.013 (P<0.0001), and Dice similarity 0.992±0.007 (P<0.0001). The corresponding area under the curve for four calcium detection techniques is: 1.0, 1.0, 0.97 and 0.93, respectively. The mean overall performance improvement is 38.54{\%} and when adapting calibration block. The mean workflow speed improvement is 62.14{\%} when adapting multiresolution paradigm. Three clinical tests shows consistency, reliability, and stability of our well-balanced system. Conclusions A well-balanced system with a combination of Threshold embedded with Lanczos multiresolution was optimal and can be useable in clinical settings.",
keywords = "Calibration, Classification, Coronary calcium volume, Low-resolution IVUS, Multiresolution, Speed",
author = "Banchhor, {Sumit K.} and Londhe, {Narendra D.} and Tadashi Araki and Luca Saba and Petia Radeva and Laird, {John R.} and Suri, {Jasjit S.} and {Fellow AIMBE}",
year = "2017",
month = "5",
day = "1",
doi = "10.1016/j.compbiomed.2017.03.026",
language = "English (US)",
volume = "84",
pages = "168--181",
journal = "Computers in Biology and Medicine",
issn = "0010-4825",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Well-balanced system for coronary calcium detection and volume measurement in a low resolution intravascular ultrasound videos

AU - Banchhor, Sumit K.

AU - Londhe, Narendra D.

AU - Araki, Tadashi

AU - Saba, Luca

AU - Radeva, Petia

AU - Laird, John R.

AU - Suri, Jasjit S.

AU - Fellow AIMBE

PY - 2017/5/1

Y1 - 2017/5/1

N2 - Background Accurate and fast quantitative assessment of calcium volume is required during the planning of percutaneous coronary interventions procedures. Low resolution in intravascular ultrasound (IVUS) coronary videos poses a threat to calcium detection causing over-estimation in volume measurement. We introduce a correction block that counter-balances the bias introduced during the calcium detection process. Method Nineteen patients image dataset (around 40,090 frames), IRB approved, were collected using 40 MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5 mm/sec). A new set of 20 generalized and well-balanced systems each consisting of three stages: (i) calcium detection, (ii) calibration and (iii) measurement, while ensuring accuracy of four soft classifiers (Threshold, FCM, K-means and HMRF) and workflow speed using five multiresolution techniques (bilinear, bicubic, wavelet, Lanczos, Gaussian Pyramid) were designed. Results of the three calcium detection methods were benchmarked against the Threshold-based method. Results All 20 well-balanced systems with calibration block show superior performance. Using calibration block, FCM versus Threshold-based method shows the highest cross-correlation 0.99 (P<0.0001), Jaccard index 0.984±0.013 (P<0.0001), and Dice similarity 0.992±0.007 (P<0.0001). The corresponding area under the curve for four calcium detection techniques is: 1.0, 1.0, 0.97 and 0.93, respectively. The mean overall performance improvement is 38.54% and when adapting calibration block. The mean workflow speed improvement is 62.14% when adapting multiresolution paradigm. Three clinical tests shows consistency, reliability, and stability of our well-balanced system. Conclusions A well-balanced system with a combination of Threshold embedded with Lanczos multiresolution was optimal and can be useable in clinical settings.

AB - Background Accurate and fast quantitative assessment of calcium volume is required during the planning of percutaneous coronary interventions procedures. Low resolution in intravascular ultrasound (IVUS) coronary videos poses a threat to calcium detection causing over-estimation in volume measurement. We introduce a correction block that counter-balances the bias introduced during the calcium detection process. Method Nineteen patients image dataset (around 40,090 frames), IRB approved, were collected using 40 MHz IVUS catheter (Atlantis® SR Pro, Boston Scientific®, pullback speed of 0.5 mm/sec). A new set of 20 generalized and well-balanced systems each consisting of three stages: (i) calcium detection, (ii) calibration and (iii) measurement, while ensuring accuracy of four soft classifiers (Threshold, FCM, K-means and HMRF) and workflow speed using five multiresolution techniques (bilinear, bicubic, wavelet, Lanczos, Gaussian Pyramid) were designed. Results of the three calcium detection methods were benchmarked against the Threshold-based method. Results All 20 well-balanced systems with calibration block show superior performance. Using calibration block, FCM versus Threshold-based method shows the highest cross-correlation 0.99 (P<0.0001), Jaccard index 0.984±0.013 (P<0.0001), and Dice similarity 0.992±0.007 (P<0.0001). The corresponding area under the curve for four calcium detection techniques is: 1.0, 1.0, 0.97 and 0.93, respectively. The mean overall performance improvement is 38.54% and when adapting calibration block. The mean workflow speed improvement is 62.14% when adapting multiresolution paradigm. Three clinical tests shows consistency, reliability, and stability of our well-balanced system. Conclusions A well-balanced system with a combination of Threshold embedded with Lanczos multiresolution was optimal and can be useable in clinical settings.

KW - Calibration

KW - Classification

KW - Coronary calcium volume

KW - Low-resolution IVUS

KW - Multiresolution

KW - Speed

UR - http://www.scopus.com/inward/record.url?scp=85017104292&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85017104292&partnerID=8YFLogxK

U2 - 10.1016/j.compbiomed.2017.03.026

DO - 10.1016/j.compbiomed.2017.03.026

M3 - Article

VL - 84

SP - 168

EP - 181

JO - Computers in Biology and Medicine

JF - Computers in Biology and Medicine

SN - 0010-4825

ER -