WE‐D‐330A‐06: Dual Projection Imaging System for Small Animal Research

O. Velazquez, John M Boone, K. Yang, G. Burkett

Research output: Contribution to journalArticle

Abstract

Purpose: The use of small mammals as models of human diseases has increased in the last several years. These models provide a valuable research tool to characterize these diseases and to evaluate new therapies. Dedicated imaging systems, with the resolution and sensitivity to allow in vivo studies in small animals, reduce the number of animals required for a given study and offer the possibility of serial studies in the same animal. A dual two‐dimensional imaging system has been developed to monitor tumor development in mice and other small animals. Method and Materials: This imaging system combines functional information gained from projection nuclear emission imaging with the anatomical context provided by an x‐ray transmission image. The system captures a nuclear image in one side of a single computed radiography detector (CR plate) and then the plate is moved to acquire an x‐ray image in the opposite side. The nuclear image is formed by using a parallel hole collimator. Four fiducial markers, that are visible in both images, are attached to the system. A transformation algorithm uses the information from the fiducial markers to align the images. The nuclear emission image is color coded and overlaid onto the gray‐scale x‐ray image. Results: For the assessment of the imaging system, a tissue‐equivalent phantom was manufactured. Initial investigations used I‐125. The spatial resolution, contrast, and detected scattered photon levels have been measured for both x‐ray and nuclear imaging, and the sensitivity of the nuclear imaging system was also measured. Conclusion: The lower radiation levels, faster throughput, and lower cost of this imaging system would allow the evaluation of functional activity more frequently in serial studies. This imaging system would complement tomographic systems by allowing rapid pre‐screening of animals when a complete 3D volume data set is not necessary.

Original languageEnglish (US)
Pages (from-to)2240-2241
Number of pages2
JournalMedical Physics
Volume33
Issue number6
DOIs
StatePublished - 2006

Fingerprint

Fiducial Markers
X-Rays
Photons
Radiography
Mammals
Color
Radiation
Costs and Cost Analysis
Research
Neoplasms
Therapeutics

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

WE‐D‐330A‐06 : Dual Projection Imaging System for Small Animal Research. / Velazquez, O.; Boone, John M; Yang, K.; Burkett, G.

In: Medical Physics, Vol. 33, No. 6, 2006, p. 2240-2241.

Research output: Contribution to journalArticle

Velazquez, O. ; Boone, John M ; Yang, K. ; Burkett, G. / WE‐D‐330A‐06 : Dual Projection Imaging System for Small Animal Research. In: Medical Physics. 2006 ; Vol. 33, No. 6. pp. 2240-2241.
@article{d4cca606473347b6836b12738eb80dd0,
title = "WE‐D‐330A‐06: Dual Projection Imaging System for Small Animal Research",
abstract = "Purpose: The use of small mammals as models of human diseases has increased in the last several years. These models provide a valuable research tool to characterize these diseases and to evaluate new therapies. Dedicated imaging systems, with the resolution and sensitivity to allow in vivo studies in small animals, reduce the number of animals required for a given study and offer the possibility of serial studies in the same animal. A dual two‐dimensional imaging system has been developed to monitor tumor development in mice and other small animals. Method and Materials: This imaging system combines functional information gained from projection nuclear emission imaging with the anatomical context provided by an x‐ray transmission image. The system captures a nuclear image in one side of a single computed radiography detector (CR plate) and then the plate is moved to acquire an x‐ray image in the opposite side. The nuclear image is formed by using a parallel hole collimator. Four fiducial markers, that are visible in both images, are attached to the system. A transformation algorithm uses the information from the fiducial markers to align the images. The nuclear emission image is color coded and overlaid onto the gray‐scale x‐ray image. Results: For the assessment of the imaging system, a tissue‐equivalent phantom was manufactured. Initial investigations used I‐125. The spatial resolution, contrast, and detected scattered photon levels have been measured for both x‐ray and nuclear imaging, and the sensitivity of the nuclear imaging system was also measured. Conclusion: The lower radiation levels, faster throughput, and lower cost of this imaging system would allow the evaluation of functional activity more frequently in serial studies. This imaging system would complement tomographic systems by allowing rapid pre‐screening of animals when a complete 3D volume data set is not necessary.",
author = "O. Velazquez and Boone, {John M} and K. Yang and G. Burkett",
year = "2006",
doi = "10.1118/1.2241744",
language = "English (US)",
volume = "33",
pages = "2240--2241",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - WE‐D‐330A‐06

T2 - Dual Projection Imaging System for Small Animal Research

AU - Velazquez, O.

AU - Boone, John M

AU - Yang, K.

AU - Burkett, G.

PY - 2006

Y1 - 2006

N2 - Purpose: The use of small mammals as models of human diseases has increased in the last several years. These models provide a valuable research tool to characterize these diseases and to evaluate new therapies. Dedicated imaging systems, with the resolution and sensitivity to allow in vivo studies in small animals, reduce the number of animals required for a given study and offer the possibility of serial studies in the same animal. A dual two‐dimensional imaging system has been developed to monitor tumor development in mice and other small animals. Method and Materials: This imaging system combines functional information gained from projection nuclear emission imaging with the anatomical context provided by an x‐ray transmission image. The system captures a nuclear image in one side of a single computed radiography detector (CR plate) and then the plate is moved to acquire an x‐ray image in the opposite side. The nuclear image is formed by using a parallel hole collimator. Four fiducial markers, that are visible in both images, are attached to the system. A transformation algorithm uses the information from the fiducial markers to align the images. The nuclear emission image is color coded and overlaid onto the gray‐scale x‐ray image. Results: For the assessment of the imaging system, a tissue‐equivalent phantom was manufactured. Initial investigations used I‐125. The spatial resolution, contrast, and detected scattered photon levels have been measured for both x‐ray and nuclear imaging, and the sensitivity of the nuclear imaging system was also measured. Conclusion: The lower radiation levels, faster throughput, and lower cost of this imaging system would allow the evaluation of functional activity more frequently in serial studies. This imaging system would complement tomographic systems by allowing rapid pre‐screening of animals when a complete 3D volume data set is not necessary.

AB - Purpose: The use of small mammals as models of human diseases has increased in the last several years. These models provide a valuable research tool to characterize these diseases and to evaluate new therapies. Dedicated imaging systems, with the resolution and sensitivity to allow in vivo studies in small animals, reduce the number of animals required for a given study and offer the possibility of serial studies in the same animal. A dual two‐dimensional imaging system has been developed to monitor tumor development in mice and other small animals. Method and Materials: This imaging system combines functional information gained from projection nuclear emission imaging with the anatomical context provided by an x‐ray transmission image. The system captures a nuclear image in one side of a single computed radiography detector (CR plate) and then the plate is moved to acquire an x‐ray image in the opposite side. The nuclear image is formed by using a parallel hole collimator. Four fiducial markers, that are visible in both images, are attached to the system. A transformation algorithm uses the information from the fiducial markers to align the images. The nuclear emission image is color coded and overlaid onto the gray‐scale x‐ray image. Results: For the assessment of the imaging system, a tissue‐equivalent phantom was manufactured. Initial investigations used I‐125. The spatial resolution, contrast, and detected scattered photon levels have been measured for both x‐ray and nuclear imaging, and the sensitivity of the nuclear imaging system was also measured. Conclusion: The lower radiation levels, faster throughput, and lower cost of this imaging system would allow the evaluation of functional activity more frequently in serial studies. This imaging system would complement tomographic systems by allowing rapid pre‐screening of animals when a complete 3D volume data set is not necessary.

UR - http://www.scopus.com/inward/record.url?scp=85024804038&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024804038&partnerID=8YFLogxK

U2 - 10.1118/1.2241744

DO - 10.1118/1.2241744

M3 - Article

AN - SCOPUS:85024804038

VL - 33

SP - 2240

EP - 2241

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -