Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner

Jonathan K. Poon, Magnus L. Dahlbom, Michael E. Casey, Jinyi Qi, Simon R Cherry, Ramsey D Badawi

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

Original languageEnglish (US)
Pages (from-to)N35-N45
JournalPhysics in Medicine and Biology
Volume60
Issue number3
DOIs
StatePublished - Feb 7 2015

Fingerprint

Validation Studies
Theoretical Models
2-naphthylethyl methacrylate

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner. / Poon, Jonathan K.; Dahlbom, Magnus L.; Casey, Michael E.; Qi, Jinyi; Cherry, Simon R; Badawi, Ramsey D.

In: Physics in Medicine and Biology, Vol. 60, No. 3, 07.02.2015, p. N35-N45.

Research output: Contribution to journalArticle

Poon, Jonathan K. ; Dahlbom, Magnus L. ; Casey, Michael E. ; Qi, Jinyi ; Cherry, Simon R ; Badawi, Ramsey D. / Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner. In: Physics in Medicine and Biology. 2015 ; Vol. 60, No. 3. pp. N35-N45.
@article{8b31e477716c4803b41cb99c1233043d,
title = "Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner",
abstract = "Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23{\%} and the spatial resolution test by 13-28{\%}, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8{\%} for the count rate test and approximately 3-11{\%} for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.",
author = "Poon, {Jonathan K.} and Dahlbom, {Magnus L.} and Casey, {Michael E.} and Jinyi Qi and Cherry, {Simon R} and Badawi, {Ramsey D}",
year = "2015",
month = "2",
day = "7",
doi = "10.1088/0031-9155/60/3/N35",
language = "English (US)",
volume = "60",
pages = "N35--N45",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Validation of the SimSET simulation package for modeling the Siemens Biograph mCT PET scanner

AU - Poon, Jonathan K.

AU - Dahlbom, Magnus L.

AU - Casey, Michael E.

AU - Qi, Jinyi

AU - Cherry, Simon R

AU - Badawi, Ramsey D

PY - 2015/2/7

Y1 - 2015/2/7

N2 - Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

AB - Monte Carlo simulation provides a valuable tool in performance assessment and optimization of system design parameters for PET scanners. SimSET is a popular Monte Carlo simulation toolkit that features fast simulation time, as well as variance reduction tools to further enhance computational efficiency. However, SimSET has lacked the ability to simulate block detectors until its most recent release. Our goal is to validate new features of SimSET by developing a simulation model of the Siemens Biograph mCT PET scanner and comparing the results to a simulation model developed in the GATE simulation suite and to experimental results. We used the NEMA NU-2 2007 scatter fraction, count rates, and spatial resolution protocols to validate the SimSET simulation model and its new features. The SimSET model overestimated the experimental results of the count rate tests by 11-23% and the spatial resolution test by 13-28%, which is comparable to previous validation studies of other PET scanners in the literature. The difference between the SimSET and GATE simulation was approximately 4-8% for the count rate test and approximately 3-11% for the spatial resolution test. In terms of computational time, SimSET performed simulations approximately 11 times faster than GATE simulations. The new block detector model in SimSET offers a fast and reasonably accurate simulation toolkit for PET imaging applications.

UR - http://www.scopus.com/inward/record.url?scp=84921292200&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84921292200&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/60/3/N35

DO - 10.1088/0031-9155/60/3/N35

M3 - Article

C2 - 25586800

AN - SCOPUS:84921292200

VL - 60

SP - N35-N45

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 3

ER -