UV-absorbing intraocular lenses: Safety, efficacy, and consequences for the cataract patient

John S Werner, Lothar Spillmann

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

The crystalline lens absorbs most of the incident UV radiation between 300 and 400 nm and thereby protects the retina from a significant, potential source of photochemical damage. This protection is lost when the lens is removed by cataract surgery, but can be restored by the implantation of an intraocular lens (IOL) that has UV-absorbing chromophores incorporated into a polymethylmethacrylate (PMMA) substrate. Spectrophotometric data show that the various, commercially available, UV-absorbing IOLs are not equally effective in absorbing UV radiation; thus, a standard, quantitative metric for comparing their performance is proposed. Cytotoxicity and biocompatibility studies have failed to demonstrate that UV-absorbing IOLs are unsafe, even when damaged by Nd:YAG lasers used for photodiscission posterior capsulotomy. There are positive consequences for the pseudophakic patient with a UV-absorbing IOL, in that it may restore normal spectral sensitivity, reduce erythropsia and cystoid macular edema, and stabilize the blood-vitreous barrier.

Original languageEnglish (US)
Pages (from-to)248-256
Number of pages9
JournalGraefe's Archive for Clinical and Experimental Ophthalmology
Volume227
Issue number3
DOIs
StatePublished - May 1989
Externally publishedYes

Fingerprint

Intraocular Lenses
Cataract
Posterior Capsulotomy
Radiation
Safety
Crystalline Lens
Intraocular Lens Implantation
Macular Edema
Solid-State Lasers
Polymethyl Methacrylate
Lenses
Retina

ASJC Scopus subject areas

  • Ophthalmology

Cite this

UV-absorbing intraocular lenses : Safety, efficacy, and consequences for the cataract patient. / Werner, John S; Spillmann, Lothar.

In: Graefe's Archive for Clinical and Experimental Ophthalmology, Vol. 227, No. 3, 05.1989, p. 248-256.

Research output: Contribution to journalArticle

@article{a781cf1cf4a74f5c8b8971dc01dc34d4,
title = "UV-absorbing intraocular lenses: Safety, efficacy, and consequences for the cataract patient",
abstract = "The crystalline lens absorbs most of the incident UV radiation between 300 and 400 nm and thereby protects the retina from a significant, potential source of photochemical damage. This protection is lost when the lens is removed by cataract surgery, but can be restored by the implantation of an intraocular lens (IOL) that has UV-absorbing chromophores incorporated into a polymethylmethacrylate (PMMA) substrate. Spectrophotometric data show that the various, commercially available, UV-absorbing IOLs are not equally effective in absorbing UV radiation; thus, a standard, quantitative metric for comparing their performance is proposed. Cytotoxicity and biocompatibility studies have failed to demonstrate that UV-absorbing IOLs are unsafe, even when damaged by Nd:YAG lasers used for photodiscission posterior capsulotomy. There are positive consequences for the pseudophakic patient with a UV-absorbing IOL, in that it may restore normal spectral sensitivity, reduce erythropsia and cystoid macular edema, and stabilize the blood-vitreous barrier.",
author = "Werner, {John S} and Lothar Spillmann",
year = "1989",
month = "5",
doi = "10.1007/BF02172758",
language = "English (US)",
volume = "227",
pages = "248--256",
journal = "Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie",
issn = "0065-6100",
publisher = "Springer Verlag",
number = "3",

}

TY - JOUR

T1 - UV-absorbing intraocular lenses

T2 - Safety, efficacy, and consequences for the cataract patient

AU - Werner, John S

AU - Spillmann, Lothar

PY - 1989/5

Y1 - 1989/5

N2 - The crystalline lens absorbs most of the incident UV radiation between 300 and 400 nm and thereby protects the retina from a significant, potential source of photochemical damage. This protection is lost when the lens is removed by cataract surgery, but can be restored by the implantation of an intraocular lens (IOL) that has UV-absorbing chromophores incorporated into a polymethylmethacrylate (PMMA) substrate. Spectrophotometric data show that the various, commercially available, UV-absorbing IOLs are not equally effective in absorbing UV radiation; thus, a standard, quantitative metric for comparing their performance is proposed. Cytotoxicity and biocompatibility studies have failed to demonstrate that UV-absorbing IOLs are unsafe, even when damaged by Nd:YAG lasers used for photodiscission posterior capsulotomy. There are positive consequences for the pseudophakic patient with a UV-absorbing IOL, in that it may restore normal spectral sensitivity, reduce erythropsia and cystoid macular edema, and stabilize the blood-vitreous barrier.

AB - The crystalline lens absorbs most of the incident UV radiation between 300 and 400 nm and thereby protects the retina from a significant, potential source of photochemical damage. This protection is lost when the lens is removed by cataract surgery, but can be restored by the implantation of an intraocular lens (IOL) that has UV-absorbing chromophores incorporated into a polymethylmethacrylate (PMMA) substrate. Spectrophotometric data show that the various, commercially available, UV-absorbing IOLs are not equally effective in absorbing UV radiation; thus, a standard, quantitative metric for comparing their performance is proposed. Cytotoxicity and biocompatibility studies have failed to demonstrate that UV-absorbing IOLs are unsafe, even when damaged by Nd:YAG lasers used for photodiscission posterior capsulotomy. There are positive consequences for the pseudophakic patient with a UV-absorbing IOL, in that it may restore normal spectral sensitivity, reduce erythropsia and cystoid macular edema, and stabilize the blood-vitreous barrier.

UR - http://www.scopus.com/inward/record.url?scp=0024390491&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024390491&partnerID=8YFLogxK

U2 - 10.1007/BF02172758

DO - 10.1007/BF02172758

M3 - Article

C2 - 2661334

AN - SCOPUS:0024390491

VL - 227

SP - 248

EP - 256

JO - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie

JF - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie

SN - 0065-6100

IS - 3

ER -