Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy

John P McGahan, Janice Ryu, Maria Fogata

Research output: Contribution to journalArticle

39 Citations (Scopus)

Abstract

Purpose A pelvic phantom was constructed to evaluate the effect of ultrasound probe pressure during performance of bipolar acquisition technique (BAT) for prostate localization for radiotherapy. Methods and materials A pelvic phantom of a gelatin mold with a water-filled balloon representing the bladder and rectum and a central encapsulated clay sphere representing the prostate was constructed. This phantom was then scanned using planning computed tomography (CT). The geometric information of the phantom was outlined in two planes. The phantom was then scanned using the BAT system with mild and moderate ultrasound probe pressure. Differences in prostate depth between the CT and BAT systems were displayed. Results A difference of 1 cm between the phantom surface and the prostate could be produced with moderate ultrasound probe pressure. The differences were similar between the CT- and BAT-generated contours and were dependent on the ultrasound probe pressure. Conclusion Care must be taken not to cause any alteration in prostate localization with increasing ultrasound probe pressure when using BAT localization. Increased probe pressure may introduce errors in prostate localization and under dose the target.

Original languageEnglish (US)
Pages (from-to)788-793
Number of pages6
JournalInternational Journal of Radiation Oncology Biology Physics
Volume60
Issue number3
DOIs
StatePublished - Nov 1 2004

Fingerprint

pressure sensors
Prostate
radiation therapy
Research Design
Radiotherapy
acquisition
Pressure
tomography
Tomography
rectum
bladder
gelatins
balloons
Gelatin
Rectum
clays
planning
Urinary Bladder
Fungi
dosage

Keywords

  • External beam radiotherapy
  • Prostate cancer
  • Ultrasound probe pressure

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Radiation

Cite this

Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy. / McGahan, John P; Ryu, Janice; Fogata, Maria.

In: International Journal of Radiation Oncology Biology Physics, Vol. 60, No. 3, 01.11.2004, p. 788-793.

Research output: Contribution to journalArticle

@article{df5f01dc489a4ef1ba3ee5c031f4fb89,
title = "Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy",
abstract = "Purpose A pelvic phantom was constructed to evaluate the effect of ultrasound probe pressure during performance of bipolar acquisition technique (BAT) for prostate localization for radiotherapy. Methods and materials A pelvic phantom of a gelatin mold with a water-filled balloon representing the bladder and rectum and a central encapsulated clay sphere representing the prostate was constructed. This phantom was then scanned using planning computed tomography (CT). The geometric information of the phantom was outlined in two planes. The phantom was then scanned using the BAT system with mild and moderate ultrasound probe pressure. Differences in prostate depth between the CT and BAT systems were displayed. Results A difference of 1 cm between the phantom surface and the prostate could be produced with moderate ultrasound probe pressure. The differences were similar between the CT- and BAT-generated contours and were dependent on the ultrasound probe pressure. Conclusion Care must be taken not to cause any alteration in prostate localization with increasing ultrasound probe pressure when using BAT localization. Increased probe pressure may introduce errors in prostate localization and under dose the target.",
keywords = "External beam radiotherapy, Prostate cancer, Ultrasound probe pressure",
author = "McGahan, {John P} and Janice Ryu and Maria Fogata",
year = "2004",
month = "11",
day = "1",
doi = "10.1016/j.ijrobp.2004.04.005",
language = "English (US)",
volume = "60",
pages = "788--793",
journal = "International Journal of Radiation Oncology Biology Physics",
issn = "0360-3016",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Ultrasound probe pressure as a source of error in prostate localization for external beam radiotherapy

AU - McGahan, John P

AU - Ryu, Janice

AU - Fogata, Maria

PY - 2004/11/1

Y1 - 2004/11/1

N2 - Purpose A pelvic phantom was constructed to evaluate the effect of ultrasound probe pressure during performance of bipolar acquisition technique (BAT) for prostate localization for radiotherapy. Methods and materials A pelvic phantom of a gelatin mold with a water-filled balloon representing the bladder and rectum and a central encapsulated clay sphere representing the prostate was constructed. This phantom was then scanned using planning computed tomography (CT). The geometric information of the phantom was outlined in two planes. The phantom was then scanned using the BAT system with mild and moderate ultrasound probe pressure. Differences in prostate depth between the CT and BAT systems were displayed. Results A difference of 1 cm between the phantom surface and the prostate could be produced with moderate ultrasound probe pressure. The differences were similar between the CT- and BAT-generated contours and were dependent on the ultrasound probe pressure. Conclusion Care must be taken not to cause any alteration in prostate localization with increasing ultrasound probe pressure when using BAT localization. Increased probe pressure may introduce errors in prostate localization and under dose the target.

AB - Purpose A pelvic phantom was constructed to evaluate the effect of ultrasound probe pressure during performance of bipolar acquisition technique (BAT) for prostate localization for radiotherapy. Methods and materials A pelvic phantom of a gelatin mold with a water-filled balloon representing the bladder and rectum and a central encapsulated clay sphere representing the prostate was constructed. This phantom was then scanned using planning computed tomography (CT). The geometric information of the phantom was outlined in two planes. The phantom was then scanned using the BAT system with mild and moderate ultrasound probe pressure. Differences in prostate depth between the CT and BAT systems were displayed. Results A difference of 1 cm between the phantom surface and the prostate could be produced with moderate ultrasound probe pressure. The differences were similar between the CT- and BAT-generated contours and were dependent on the ultrasound probe pressure. Conclusion Care must be taken not to cause any alteration in prostate localization with increasing ultrasound probe pressure when using BAT localization. Increased probe pressure may introduce errors in prostate localization and under dose the target.

KW - External beam radiotherapy

KW - Prostate cancer

KW - Ultrasound probe pressure

UR - http://www.scopus.com/inward/record.url?scp=4744359708&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4744359708&partnerID=8YFLogxK

U2 - 10.1016/j.ijrobp.2004.04.005

DO - 10.1016/j.ijrobp.2004.04.005

M3 - Article

VL - 60

SP - 788

EP - 793

JO - International Journal of Radiation Oncology Biology Physics

JF - International Journal of Radiation Oncology Biology Physics

SN - 0360-3016

IS - 3

ER -