Ultrasound localization of the sacral plexus using a parasacral approach

Alon Ben-Ari, Rama Joshi, Anna Uskova, Jacques E. Chelly

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

In this report, we describe the feasibility of locating the sacral plexus nerve using a parasacral approach and an ultrasound-guided technique. The parasacral region using a curved probe (2-5 MHz) was scanned in 17 patients in search of the medial border of the ischial bone and the lateral border of the sacrum, which represent the limit of the greater sciatic foramen. In addition, attempts were made to identify the piriformis muscles and the gluteal arteries. The sacral plexus was identified at the level of the sciatic foramen as a round hyperechoic structure. The gluteal arteries were identified in 10 of 17 patients, but we failed to positively identify the piriformis muscle in any patient. To confirm localization of the sacral plexus, an insulated needle attached to a nerve stimulator was advanced and, in each case, a sacral plexus motor response was elicited (plantar flexion-12, dorsal flexion-1, hamstring muscle stimulation-3, gastrocnemius muscle stimulation-1-not recorded) at a current between 0.2 and 0.5 mA. No complications were observed. This report confirms the feasibility of using ultrasound to locate the sacral plexus using a parasacral approach.

Original languageEnglish (US)
Pages (from-to)1977-1980
Number of pages4
JournalAnesthesia and Analgesia
Volume108
Issue number6
DOIs
StatePublished - Jun 1 2009
Externally publishedYes

Fingerprint

Lumbosacral Plexus
Arteries
Sacrum
Muscles
Needles
Skeletal Muscle
Bone and Bones

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Ultrasound localization of the sacral plexus using a parasacral approach. / Ben-Ari, Alon; Joshi, Rama; Uskova, Anna; Chelly, Jacques E.

In: Anesthesia and Analgesia, Vol. 108, No. 6, 01.06.2009, p. 1977-1980.

Research output: Contribution to journalArticle

Ben-Ari, Alon ; Joshi, Rama ; Uskova, Anna ; Chelly, Jacques E. / Ultrasound localization of the sacral plexus using a parasacral approach. In: Anesthesia and Analgesia. 2009 ; Vol. 108, No. 6. pp. 1977-1980.
@article{fe2f215ca3f14fa5adac137306da15ef,
title = "Ultrasound localization of the sacral plexus using a parasacral approach",
abstract = "In this report, we describe the feasibility of locating the sacral plexus nerve using a parasacral approach and an ultrasound-guided technique. The parasacral region using a curved probe (2-5 MHz) was scanned in 17 patients in search of the medial border of the ischial bone and the lateral border of the sacrum, which represent the limit of the greater sciatic foramen. In addition, attempts were made to identify the piriformis muscles and the gluteal arteries. The sacral plexus was identified at the level of the sciatic foramen as a round hyperechoic structure. The gluteal arteries were identified in 10 of 17 patients, but we failed to positively identify the piriformis muscle in any patient. To confirm localization of the sacral plexus, an insulated needle attached to a nerve stimulator was advanced and, in each case, a sacral plexus motor response was elicited (plantar flexion-12, dorsal flexion-1, hamstring muscle stimulation-3, gastrocnemius muscle stimulation-1-not recorded) at a current between 0.2 and 0.5 mA. No complications were observed. This report confirms the feasibility of using ultrasound to locate the sacral plexus using a parasacral approach.",
author = "Alon Ben-Ari and Rama Joshi and Anna Uskova and Chelly, {Jacques E.}",
year = "2009",
month = "6",
day = "1",
doi = "10.1213/ane.0b013e3181a04d8e",
language = "English (US)",
volume = "108",
pages = "1977--1980",
journal = "Anesthesia and Analgesia",
issn = "0003-2999",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Ultrasound localization of the sacral plexus using a parasacral approach

AU - Ben-Ari, Alon

AU - Joshi, Rama

AU - Uskova, Anna

AU - Chelly, Jacques E.

PY - 2009/6/1

Y1 - 2009/6/1

N2 - In this report, we describe the feasibility of locating the sacral plexus nerve using a parasacral approach and an ultrasound-guided technique. The parasacral region using a curved probe (2-5 MHz) was scanned in 17 patients in search of the medial border of the ischial bone and the lateral border of the sacrum, which represent the limit of the greater sciatic foramen. In addition, attempts were made to identify the piriformis muscles and the gluteal arteries. The sacral plexus was identified at the level of the sciatic foramen as a round hyperechoic structure. The gluteal arteries were identified in 10 of 17 patients, but we failed to positively identify the piriformis muscle in any patient. To confirm localization of the sacral plexus, an insulated needle attached to a nerve stimulator was advanced and, in each case, a sacral plexus motor response was elicited (plantar flexion-12, dorsal flexion-1, hamstring muscle stimulation-3, gastrocnemius muscle stimulation-1-not recorded) at a current between 0.2 and 0.5 mA. No complications were observed. This report confirms the feasibility of using ultrasound to locate the sacral plexus using a parasacral approach.

AB - In this report, we describe the feasibility of locating the sacral plexus nerve using a parasacral approach and an ultrasound-guided technique. The parasacral region using a curved probe (2-5 MHz) was scanned in 17 patients in search of the medial border of the ischial bone and the lateral border of the sacrum, which represent the limit of the greater sciatic foramen. In addition, attempts were made to identify the piriformis muscles and the gluteal arteries. The sacral plexus was identified at the level of the sciatic foramen as a round hyperechoic structure. The gluteal arteries were identified in 10 of 17 patients, but we failed to positively identify the piriformis muscle in any patient. To confirm localization of the sacral plexus, an insulated needle attached to a nerve stimulator was advanced and, in each case, a sacral plexus motor response was elicited (plantar flexion-12, dorsal flexion-1, hamstring muscle stimulation-3, gastrocnemius muscle stimulation-1-not recorded) at a current between 0.2 and 0.5 mA. No complications were observed. This report confirms the feasibility of using ultrasound to locate the sacral plexus using a parasacral approach.

UR - http://www.scopus.com/inward/record.url?scp=66349101607&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=66349101607&partnerID=8YFLogxK

U2 - 10.1213/ane.0b013e3181a04d8e

DO - 10.1213/ane.0b013e3181a04d8e

M3 - Article

VL - 108

SP - 1977

EP - 1980

JO - Anesthesia and Analgesia

JF - Anesthesia and Analgesia

SN - 0003-2999

IS - 6