TU‐D‐I‐611‐01: A General Method for Micro CT System Calibration with Phantom Scan

K. Yang, D. Miller, John M Boone

Research output: Contribution to journalArticle

Abstract

Purpose: System calibration of a micro CT scanner for anatomic imaging of small animals. Method and Materials: A phantom was constructed with lead ball bearings (200 μm in diameter) and scanned with a micro CT scanner designed and built in our laboratory. A general mathematical algorithm was developed to locate the X‐ray focal spot and measure the source to detector distance (SID) and the azimuthal rotation of the detector with information acquired from the projection image of the phantom. A wire phantom (0.070mm Ni‐Cd) was scanned to calibrate the angle measurement of the stepping motor which drives the rotating stage of the scanner, and also to measure the source to iso‐center distance (SIC). An array of different objects was scanned and reconstructed with these calibrated parameters to evaluate the calibration result. Results: With the calibration procedure described, critical system parameters required for cone beam reconstruction including SIC, SID, x‐ray focal spot location, detector rotation angle, and stage rotation angle were measured with high precision. Subsequent phantom testing demonstrated the accuracy of this calibration method by qualitative artifact assessment, and spatial resolution metrics (MTF) also demonstrated excellent performance. Conclusion: A simple but precise method for system calibration of a cone beam micro CT system using flat panel detector was developed. This method is likely useful for CT systems across different scales (from micro CT to human CT).

Original languageEnglish (US)
Number of pages1
JournalMedical Physics
Volume32
Issue number6
DOIs
StatePublished - Jan 1 2005

Fingerprint

Calibration
Sudden Infant Death
X-Rays
Cone-Beam Computed Tomography
Artifacts

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

TU‐D‐I‐611‐01 : A General Method for Micro CT System Calibration with Phantom Scan. / Yang, K.; Miller, D.; Boone, John M.

In: Medical Physics, Vol. 32, No. 6, 01.01.2005.

Research output: Contribution to journalArticle

@article{b574035c70f84a21b0ff625f4da79f32,
title = "TU‐D‐I‐611‐01: A General Method for Micro CT System Calibration with Phantom Scan",
abstract = "Purpose: System calibration of a micro CT scanner for anatomic imaging of small animals. Method and Materials: A phantom was constructed with lead ball bearings (200 μm in diameter) and scanned with a micro CT scanner designed and built in our laboratory. A general mathematical algorithm was developed to locate the X‐ray focal spot and measure the source to detector distance (SID) and the azimuthal rotation of the detector with information acquired from the projection image of the phantom. A wire phantom (0.070mm Ni‐Cd) was scanned to calibrate the angle measurement of the stepping motor which drives the rotating stage of the scanner, and also to measure the source to iso‐center distance (SIC). An array of different objects was scanned and reconstructed with these calibrated parameters to evaluate the calibration result. Results: With the calibration procedure described, critical system parameters required for cone beam reconstruction including SIC, SID, x‐ray focal spot location, detector rotation angle, and stage rotation angle were measured with high precision. Subsequent phantom testing demonstrated the accuracy of this calibration method by qualitative artifact assessment, and spatial resolution metrics (MTF) also demonstrated excellent performance. Conclusion: A simple but precise method for system calibration of a cone beam micro CT system using flat panel detector was developed. This method is likely useful for CT systems across different scales (from micro CT to human CT).",
author = "K. Yang and D. Miller and Boone, {John M}",
year = "2005",
month = "1",
day = "1",
doi = "10.1118/1.1998380",
language = "English (US)",
volume = "32",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - TU‐D‐I‐611‐01

T2 - A General Method for Micro CT System Calibration with Phantom Scan

AU - Yang, K.

AU - Miller, D.

AU - Boone, John M

PY - 2005/1/1

Y1 - 2005/1/1

N2 - Purpose: System calibration of a micro CT scanner for anatomic imaging of small animals. Method and Materials: A phantom was constructed with lead ball bearings (200 μm in diameter) and scanned with a micro CT scanner designed and built in our laboratory. A general mathematical algorithm was developed to locate the X‐ray focal spot and measure the source to detector distance (SID) and the azimuthal rotation of the detector with information acquired from the projection image of the phantom. A wire phantom (0.070mm Ni‐Cd) was scanned to calibrate the angle measurement of the stepping motor which drives the rotating stage of the scanner, and also to measure the source to iso‐center distance (SIC). An array of different objects was scanned and reconstructed with these calibrated parameters to evaluate the calibration result. Results: With the calibration procedure described, critical system parameters required for cone beam reconstruction including SIC, SID, x‐ray focal spot location, detector rotation angle, and stage rotation angle were measured with high precision. Subsequent phantom testing demonstrated the accuracy of this calibration method by qualitative artifact assessment, and spatial resolution metrics (MTF) also demonstrated excellent performance. Conclusion: A simple but precise method for system calibration of a cone beam micro CT system using flat panel detector was developed. This method is likely useful for CT systems across different scales (from micro CT to human CT).

AB - Purpose: System calibration of a micro CT scanner for anatomic imaging of small animals. Method and Materials: A phantom was constructed with lead ball bearings (200 μm in diameter) and scanned with a micro CT scanner designed and built in our laboratory. A general mathematical algorithm was developed to locate the X‐ray focal spot and measure the source to detector distance (SID) and the azimuthal rotation of the detector with information acquired from the projection image of the phantom. A wire phantom (0.070mm Ni‐Cd) was scanned to calibrate the angle measurement of the stepping motor which drives the rotating stage of the scanner, and also to measure the source to iso‐center distance (SIC). An array of different objects was scanned and reconstructed with these calibrated parameters to evaluate the calibration result. Results: With the calibration procedure described, critical system parameters required for cone beam reconstruction including SIC, SID, x‐ray focal spot location, detector rotation angle, and stage rotation angle were measured with high precision. Subsequent phantom testing demonstrated the accuracy of this calibration method by qualitative artifact assessment, and spatial resolution metrics (MTF) also demonstrated excellent performance. Conclusion: A simple but precise method for system calibration of a cone beam micro CT system using flat panel detector was developed. This method is likely useful for CT systems across different scales (from micro CT to human CT).

UR - http://www.scopus.com/inward/record.url?scp=85024779059&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024779059&partnerID=8YFLogxK

U2 - 10.1118/1.1998380

DO - 10.1118/1.1998380

M3 - Article

AN - SCOPUS:85024779059

VL - 32

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -