N2 - Objective: To evaluate the feasibility of performing a standard four-view focused abdominal sonography for trauma (FAST) examination during helicopter transport using a hand-carried ultrasound machine. Methods: In this prospective observational study, actual and simulated trauma patients were evaluated using the SonoSite 180 ultrasound machine by two air transport programs serving Level I trauma centers. FAST examinations were performed in flight by emergency medicine faculty, residents, flight nurses, and ultrasound technologists, who rated the difficulty posed by various factors using Likert scales (0 = not difficult to 5 = impossible). BK 117, Bell 230, and BO 105 medical helicopters flew in all aviating modes. Pilots were queried regarding avionics variations throughout the flights. Results: Ten flight sonographers performed 21 FAST examinations on 14 patients (five actual, nine simulated). The median Likert value for each parameter was 0 except for patient position, which was 1 (somewhat difficult). Interquartile ranges were 0-0 for vibration, bedding, IV catheters, monitor cables, and ventilator; 0-0.5 for backboard straps; and 0-1 for sunlight, patient position, spider straps, gurney straps, and clothing. Mean examination duration was 3.0 minutes (range 1.5 to 5.5 minutes, SD 1.3). Pilots reported no effects on avionics in any flight mode. Conclusion: The FAST examination using the SonoSite 180 in flight was rated by 10 evaluators to be performed easily. Examinations were conducted quickly and did not interfere with helicopter avionics. This digital ultrasound machine is the first one small enough to be used in most medical helicopters.
AB - Objective: To evaluate the feasibility of performing a standard four-view focused abdominal sonography for trauma (FAST) examination during helicopter transport using a hand-carried ultrasound machine. Methods: In this prospective observational study, actual and simulated trauma patients were evaluated using the SonoSite 180 ultrasound machine by two air transport programs serving Level I trauma centers. FAST examinations were performed in flight by emergency medicine faculty, residents, flight nurses, and ultrasound technologists, who rated the difficulty posed by various factors using Likert scales (0 = not difficult to 5 = impossible). BK 117, Bell 230, and BO 105 medical helicopters flew in all aviating modes. Pilots were queried regarding avionics variations throughout the flights. Results: Ten flight sonographers performed 21 FAST examinations on 14 patients (five actual, nine simulated). The median Likert value for each parameter was 0 except for patient position, which was 1 (somewhat difficult). Interquartile ranges were 0-0 for vibration, bedding, IV catheters, monitor cables, and ventilator; 0-0.5 for backboard straps; and 0-1 for sunlight, patient position, spider straps, gurney straps, and clothing. Mean examination duration was 3.0 minutes (range 1.5 to 5.5 minutes, SD 1.3). Pilots reported no effects on avionics in any flight mode. Conclusion: The FAST examination using the SonoSite 180 in flight was rated by 10 evaluators to be performed easily. Examinations were conducted quickly and did not interfere with helicopter avionics. This digital ultrasound machine is the first one small enough to be used in most medical helicopters.
KW - Air ambulance
KW - Emergency medical services
KW - Feasibility studies
KW - Ultrasonography
KW - Wounds and injuries
UR - http://www.scopus.com/inward/record.url?scp=0034293001&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034293001&partnerID=8YFLogxK
U2 - 10.1067/mmj.2000.110146
DO - 10.1067/mmj.2000.110146
M3 - Article
C2 - 11142976
AN - SCOPUS:0034293001
VL - 19
SP - 144
EP - 146
JO - Air Medical Journal
JF - Air Medical Journal
SN - 1067-991X
IS - 4
ER -