Total-body PET

Maximizing sensitivity to create new opportunities for clinical research and patient care

Simon R Cherry, Terry Jones, Joel S. Karp, Jinyi Qi, William W. Moses, Ramsey D Badawi

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4–5 for imaging a single organ such as the brain or heart. The world’s first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET.

Original languageEnglish (US)
Pages (from-to)3-12
Number of pages10
JournalJournal of Nuclear Medicine
Volume59
Issue number1
DOIs
StatePublished - Jan 1 2018

Fingerprint

Signal-To-Noise Ratio
Photons
Patient Care
Radiation
Brain
Research

Keywords

  • Instrumentation
  • Instrumentation
  • Molecular imaging
  • PET
  • PET/CT
  • Total-body imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Total-body PET : Maximizing sensitivity to create new opportunities for clinical research and patient care. / Cherry, Simon R; Jones, Terry; Karp, Joel S.; Qi, Jinyi; Moses, William W.; Badawi, Ramsey D.

In: Journal of Nuclear Medicine, Vol. 59, No. 1, 01.01.2018, p. 3-12.

Research output: Contribution to journalArticle

@article{bfe52c69e5694e3a94c4210879465fc7,
title = "Total-body PET: Maximizing sensitivity to create new opportunities for clinical research and patient care",
abstract = "PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4–5 for imaging a single organ such as the brain or heart. The world’s first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET.",
keywords = "Instrumentation, Instrumentation, Molecular imaging, PET, PET/CT, Total-body imaging",
author = "Cherry, {Simon R} and Terry Jones and Karp, {Joel S.} and Jinyi Qi and Moses, {William W.} and Badawi, {Ramsey D}",
year = "2018",
month = "1",
day = "1",
doi = "10.2967/jnumed.116.184028",
language = "English (US)",
volume = "59",
pages = "3--12",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "1",

}

TY - JOUR

T1 - Total-body PET

T2 - Maximizing sensitivity to create new opportunities for clinical research and patient care

AU - Cherry, Simon R

AU - Jones, Terry

AU - Karp, Joel S.

AU - Qi, Jinyi

AU - Moses, William W.

AU - Badawi, Ramsey D

PY - 2018/1/1

Y1 - 2018/1/1

N2 - PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4–5 for imaging a single organ such as the brain or heart. The world’s first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET.

AB - PET is widely considered the most sensitive technique available for noninvasively studying physiology, metabolism, and molecular pathways in the living human being. However, the utility of PET, being a photon-deficient modality, remains constrained by factors including low signal-to-noise ratio, long imaging times, and concerns about radiation dose. Two developments offer the potential to dramatically increase the effective sensitivity of PET. First by increasing the geometric coverage to encompass the entire body, sensitivity can be increased by a factor of about 40 for total-body imaging or a factor of about 4–5 for imaging a single organ such as the brain or heart. The world’s first total-body PET/CT scanner is currently under construction to demonstrate how this step change in sensitivity affects the way PET is used both in clinical research and in patient care. Second, there is the future prospect of significant improvements in timing resolution that could lead to further effective sensitivity gains. When combined with total-body PET, this could produce overall sensitivity gains of more than 2 orders of magnitude compared with existing state-of-the-art systems. In this article, we discuss the benefits of increasing body coverage, describe our efforts to develop a first-generation total-body PET/CT scanner, discuss selected application areas for total-body PET, and project the impact of further improvements in time-of-flight PET.

KW - Instrumentation

KW - Instrumentation

KW - Molecular imaging

KW - PET

KW - PET/CT

KW - Total-body imaging

UR - http://www.scopus.com/inward/record.url?scp=85040064403&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040064403&partnerID=8YFLogxK

U2 - 10.2967/jnumed.116.184028

DO - 10.2967/jnumed.116.184028

M3 - Article

VL - 59

SP - 3

EP - 12

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 1

ER -