The magnitude of radiation force on ultrasound contrast agents

Paul A. Dayton, John S. Allen, Katherine W. Ferrara

Research output: Contribution to journalArticle

213 Citations (Scopus)

Abstract

High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh-Plesset equation is used to estimate the radius-time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.

Original languageEnglish (US)
Pages (from-to)2183-2192
Number of pages10
JournalJournal of the Acoustical Society of America
Volume112
Issue number5 I
DOIs
StatePublished - Nov 1 2002

Fingerprint

radiation
bubbles
Rayleigh equations
high speed photography
radii
acoustics
sound waves
drag
differential equations
flow velocity
ultrasonics
examination
oscillations
cycles
fluids
estimates
pulses
Acoustics
Radiation
Ultrasound

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Cite this

The magnitude of radiation force on ultrasound contrast agents. / Dayton, Paul A.; Allen, John S.; Ferrara, Katherine W.

In: Journal of the Acoustical Society of America, Vol. 112, No. 5 I, 01.11.2002, p. 2183-2192.

Research output: Contribution to journalArticle

Dayton, Paul A. ; Allen, John S. ; Ferrara, Katherine W. / The magnitude of radiation force on ultrasound contrast agents. In: Journal of the Acoustical Society of America. 2002 ; Vol. 112, No. 5 I. pp. 2183-2192.
@article{dee98367c6524b4fb2a144adac323cfc,
title = "The magnitude of radiation force on ultrasound contrast agents",
abstract = "High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh-Plesset equation is used to estimate the radius-time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.",
author = "Dayton, {Paul A.} and Allen, {John S.} and Ferrara, {Katherine W.}",
year = "2002",
month = "11",
day = "1",
doi = "10.1121/1.1509428",
language = "English (US)",
volume = "112",
pages = "2183--2192",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "5 I",

}

TY - JOUR

T1 - The magnitude of radiation force on ultrasound contrast agents

AU - Dayton, Paul A.

AU - Allen, John S.

AU - Ferrara, Katherine W.

PY - 2002/11/1

Y1 - 2002/11/1

N2 - High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh-Plesset equation is used to estimate the radius-time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.

AB - High-speed photography of insonified bubbles with a time resolution of 10 ns allows observations of translation due to radiation force, in addition to the visualization of radial oscillations. A modified version of the Rayleigh-Plesset equation is used to estimate the radius-time behavior of insonified microbubbles, and the accuracy of this model is verified experimentally. The translation of insonified microbubbles is calculated using a differential equation relating the acceleration of the bubble to the forces due to acoustic radiation and the drag imposed by the fluid. Simulations and experiments indicate that microbubbles translate significant distances with clinically relevant parameters. A 1.5 micron radius contrast agent can translate over 5 microns during a single 20-cycle, 2.25 MHz, 380 kPa acoustic pulse, achieving velocities over 0.5 m/s. Therefore, radiation force should be considered during an ultrasonic examination because of the possibility of influencing the position and flow velocity of the contrast agents with the interrogating acoustic beam.

UR - http://www.scopus.com/inward/record.url?scp=0036841216&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036841216&partnerID=8YFLogxK

U2 - 10.1121/1.1509428

DO - 10.1121/1.1509428

M3 - Article

C2 - 12430830

AN - SCOPUS:0036841216

VL - 112

SP - 2183

EP - 2192

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 5 I

ER -