The effect of frequency dependent scattering and attenuation on the estimation of blood velocity using ultrasound

Katherine W. Ferrara, V. Ralph Algazi, Jianxin Liu

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

A comprehensive theoretical performance comparison of the wideband maximum-likelihood (WMLE) and cross-correlation strategies, previously proposed and evaluated for the estimation of blood velocity using ultrasound is presented. It is based on evaluation of the bias, local and global accuracy, and signal-to-noise ratio (SNR) performance. The results show that the intervening medium does not bias either wideband estimator, due to the effect of tracking the scattering target. The presence of intervening tissue actually improves the global accuracy of both wideband estimators, without a significant change in the local accuracy of either wideband estimator. After the transmission of P pulses, a comparison of the performance of the two strategies shows that the cross-correlation estimator requires P2 correlations to achieve performance similar to that the WMLE with P operations. In addition, the WMLE can increase the effective SNR in comparison with cross correlation.

Original languageEnglish (US)
Pages (from-to)754-767
Number of pages14
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume39
Issue number6
DOIs
StatePublished - Nov 1992

Fingerprint

Maximum likelihood
blood
Blood
Ultrasonics
attenuation
Scattering
broadband
estimators
Signal to noise ratio
scattering
cross correlation
signal to noise ratios
Tissue
evaluation
pulses

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Acoustics and Ultrasonics

Cite this

The effect of frequency dependent scattering and attenuation on the estimation of blood velocity using ultrasound. / Ferrara, Katherine W.; Algazi, V. Ralph; Liu, Jianxin.

In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 39, No. 6, 11.1992, p. 754-767.

Research output: Contribution to journalArticle

@article{cf3472f4aa0b4a0296aaf5102387a665,
title = "The effect of frequency dependent scattering and attenuation on the estimation of blood velocity using ultrasound",
abstract = "A comprehensive theoretical performance comparison of the wideband maximum-likelihood (WMLE) and cross-correlation strategies, previously proposed and evaluated for the estimation of blood velocity using ultrasound is presented. It is based on evaluation of the bias, local and global accuracy, and signal-to-noise ratio (SNR) performance. The results show that the intervening medium does not bias either wideband estimator, due to the effect of tracking the scattering target. The presence of intervening tissue actually improves the global accuracy of both wideband estimators, without a significant change in the local accuracy of either wideband estimator. After the transmission of P pulses, a comparison of the performance of the two strategies shows that the cross-correlation estimator requires P2 correlations to achieve performance similar to that the WMLE with P operations. In addition, the WMLE can increase the effective SNR in comparison with cross correlation.",
author = "Ferrara, {Katherine W.} and Algazi, {V. Ralph} and Jianxin Liu",
year = "1992",
month = "11",
doi = "10.1109/58.165561",
language = "English (US)",
volume = "39",
pages = "754--767",
journal = "IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "6",

}

TY - JOUR

T1 - The effect of frequency dependent scattering and attenuation on the estimation of blood velocity using ultrasound

AU - Ferrara, Katherine W.

AU - Algazi, V. Ralph

AU - Liu, Jianxin

PY - 1992/11

Y1 - 1992/11

N2 - A comprehensive theoretical performance comparison of the wideband maximum-likelihood (WMLE) and cross-correlation strategies, previously proposed and evaluated for the estimation of blood velocity using ultrasound is presented. It is based on evaluation of the bias, local and global accuracy, and signal-to-noise ratio (SNR) performance. The results show that the intervening medium does not bias either wideband estimator, due to the effect of tracking the scattering target. The presence of intervening tissue actually improves the global accuracy of both wideband estimators, without a significant change in the local accuracy of either wideband estimator. After the transmission of P pulses, a comparison of the performance of the two strategies shows that the cross-correlation estimator requires P2 correlations to achieve performance similar to that the WMLE with P operations. In addition, the WMLE can increase the effective SNR in comparison with cross correlation.

AB - A comprehensive theoretical performance comparison of the wideband maximum-likelihood (WMLE) and cross-correlation strategies, previously proposed and evaluated for the estimation of blood velocity using ultrasound is presented. It is based on evaluation of the bias, local and global accuracy, and signal-to-noise ratio (SNR) performance. The results show that the intervening medium does not bias either wideband estimator, due to the effect of tracking the scattering target. The presence of intervening tissue actually improves the global accuracy of both wideband estimators, without a significant change in the local accuracy of either wideband estimator. After the transmission of P pulses, a comparison of the performance of the two strategies shows that the cross-correlation estimator requires P2 correlations to achieve performance similar to that the WMLE with P operations. In addition, the WMLE can increase the effective SNR in comparison with cross correlation.

UR - http://www.scopus.com/inward/record.url?scp=0026942751&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026942751&partnerID=8YFLogxK

U2 - 10.1109/58.165561

DO - 10.1109/58.165561

M3 - Article

AN - SCOPUS:0026942751

VL - 39

SP - 754

EP - 767

JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

SN - 0885-3010

IS - 6

ER -