The analytic theory, optimization, and performance of transparent pulses

M. H. Buonocore

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress selectively the signal from flowing spins. Their intended imaging application is suppression of blood flow artifacts arising from the heart and major vessels. Diastolic images of these areas have significant artifacts that hinder accurate delineation of vessel and chamber boundaries. Transparent pulses significantly improve delineation of these boundaries and therefore could be used to improve the accuracy and precision of cross- sectional area measurements. In this paper, the analytic theory, numerical optimization, and performance characteristics are described. Experimental evidence of flow signal suppression is provided in diastolic imaging of the heart in normal subjects. The long duration and power requirements of the present generation of transparent pulses currently limits their general clinical use.

Original languageEnglish (US)
Pages (from-to)314-324
Number of pages11
JournalMagnetic Resonance in Medicine
Volume24
Issue number2
StatePublished - 1992

Fingerprint

Artifacts
Fourier Analysis

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

The analytic theory, optimization, and performance of transparent pulses. / Buonocore, M. H.

In: Magnetic Resonance in Medicine, Vol. 24, No. 2, 1992, p. 314-324.

Research output: Contribution to journalArticle

@article{344fe42d454440c6a2948605d8c71196,
title = "The analytic theory, optimization, and performance of transparent pulses",
abstract = "Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress selectively the signal from flowing spins. Their intended imaging application is suppression of blood flow artifacts arising from the heart and major vessels. Diastolic images of these areas have significant artifacts that hinder accurate delineation of vessel and chamber boundaries. Transparent pulses significantly improve delineation of these boundaries and therefore could be used to improve the accuracy and precision of cross- sectional area measurements. In this paper, the analytic theory, numerical optimization, and performance characteristics are described. Experimental evidence of flow signal suppression is provided in diastolic imaging of the heart in normal subjects. The long duration and power requirements of the present generation of transparent pulses currently limits their general clinical use.",
author = "Buonocore, {M. H.}",
year = "1992",
language = "English (US)",
volume = "24",
pages = "314--324",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - The analytic theory, optimization, and performance of transparent pulses

AU - Buonocore, M. H.

PY - 1992

Y1 - 1992

N2 - Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress selectively the signal from flowing spins. Their intended imaging application is suppression of blood flow artifacts arising from the heart and major vessels. Diastolic images of these areas have significant artifacts that hinder accurate delineation of vessel and chamber boundaries. Transparent pulses significantly improve delineation of these boundaries and therefore could be used to improve the accuracy and precision of cross- sectional area measurements. In this paper, the analytic theory, numerical optimization, and performance characteristics are described. Experimental evidence of flow signal suppression is provided in diastolic imaging of the heart in normal subjects. The long duration and power requirements of the present generation of transparent pulses currently limits their general clinical use.

AB - Transparent pulses are defined by the property of having no net effect on stationary spins, while selectively nutating and dephasing flowing spins. They are derived from the inverse scattering transform, a nonlinear extension of the inverse Fourier transform. They can be used as presaturation pulses to suppress selectively the signal from flowing spins. Their intended imaging application is suppression of blood flow artifacts arising from the heart and major vessels. Diastolic images of these areas have significant artifacts that hinder accurate delineation of vessel and chamber boundaries. Transparent pulses significantly improve delineation of these boundaries and therefore could be used to improve the accuracy and precision of cross- sectional area measurements. In this paper, the analytic theory, numerical optimization, and performance characteristics are described. Experimental evidence of flow signal suppression is provided in diastolic imaging of the heart in normal subjects. The long duration and power requirements of the present generation of transparent pulses currently limits their general clinical use.

UR - http://www.scopus.com/inward/record.url?scp=0026559992&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026559992&partnerID=8YFLogxK

M3 - Article

C2 - 1569870

AN - SCOPUS:0026559992

VL - 24

SP - 314

EP - 324

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -