Study of depth of interaction measurement using bent optical fibers

Yiping Shao, Simon R Cherry

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

Depth of interaction (DOI) measurement is an important capability for a detector suitable for use in a small PET scanner designed for breast imaging or small animal imaging. We have investigated a different scheme to determine DOI by using a position sensitive PMT (PS-PMT) at one end of an LSO crystal array for positioning and timing, and a single channel PMT connected to the other end through bent optical fibers with the ratio of the two signals to determine DOI. The main advantage of this approach is that both the PS-PMT and PMT can provide high signal-to-noise ratio outputs (improving DOI resolution) and that all technologies are available with easy readout electronics. Therefore, the design permits a relatively simple and practical solution to measure DOI while still maintaining good detector performance. We have successfully bent optical fibers, with a light loss due to fiber bending less than 10% for bending angles from 90 to 130 degrees and for a radius of curvature from 2 to 10 mm. Preliminary measurements for a detector with 2×2×21 mm3 LSO scintillators and a Hamamatsu R5900-C8 PS-PMT reveal good DOI measurement capability with this design, the measured DOI resolution ranging from 4.2 to 6 mm. It also provides excellent crystal identification and coincidence timing performance. The attenuation and scatter effects introduced by using optical fibers were also studied.

Original languageEnglish (US)
Title of host publicationIEEE Nuclear Science Symposium and Medical Imaging Conference
Place of PublicationPiscataway, NJ, United States
PublisherIEEE
Pages1440-1444
Number of pages5
Volume3
ISBN (Print)0780350227
StatePublished - 1999
EventProceedings of the 1998 IEEE Nuclear Science Symposium Conference Record - Toronto, Que, Can
Duration: Nov 8 1998Nov 14 1998

Other

OtherProceedings of the 1998 IEEE Nuclear Science Symposium Conference Record
CityToronto, Que, Can
Period11/8/9811/14/98

Fingerprint

Optical fibers
Detectors
Imaging techniques
Crystals
Phosphors
Signal to noise ratio
Animals
Electronic equipment
Fibers

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Shao, Y., & Cherry, S. R. (1999). Study of depth of interaction measurement using bent optical fibers. In IEEE Nuclear Science Symposium and Medical Imaging Conference (Vol. 3, pp. 1440-1444). Piscataway, NJ, United States: IEEE.

Study of depth of interaction measurement using bent optical fibers. / Shao, Yiping; Cherry, Simon R.

IEEE Nuclear Science Symposium and Medical Imaging Conference. Vol. 3 Piscataway, NJ, United States : IEEE, 1999. p. 1440-1444.

Research output: Chapter in Book/Report/Conference proceedingChapter

Shao, Y & Cherry, SR 1999, Study of depth of interaction measurement using bent optical fibers. in IEEE Nuclear Science Symposium and Medical Imaging Conference. vol. 3, IEEE, Piscataway, NJ, United States, pp. 1440-1444, Proceedings of the 1998 IEEE Nuclear Science Symposium Conference Record, Toronto, Que, Can, 11/8/98.
Shao Y, Cherry SR. Study of depth of interaction measurement using bent optical fibers. In IEEE Nuclear Science Symposium and Medical Imaging Conference. Vol. 3. Piscataway, NJ, United States: IEEE. 1999. p. 1440-1444
Shao, Yiping ; Cherry, Simon R. / Study of depth of interaction measurement using bent optical fibers. IEEE Nuclear Science Symposium and Medical Imaging Conference. Vol. 3 Piscataway, NJ, United States : IEEE, 1999. pp. 1440-1444
@inbook{387b2ae8d57341948cb113e2c3d907d1,
title = "Study of depth of interaction measurement using bent optical fibers",
abstract = "Depth of interaction (DOI) measurement is an important capability for a detector suitable for use in a small PET scanner designed for breast imaging or small animal imaging. We have investigated a different scheme to determine DOI by using a position sensitive PMT (PS-PMT) at one end of an LSO crystal array for positioning and timing, and a single channel PMT connected to the other end through bent optical fibers with the ratio of the two signals to determine DOI. The main advantage of this approach is that both the PS-PMT and PMT can provide high signal-to-noise ratio outputs (improving DOI resolution) and that all technologies are available with easy readout electronics. Therefore, the design permits a relatively simple and practical solution to measure DOI while still maintaining good detector performance. We have successfully bent optical fibers, with a light loss due to fiber bending less than 10{\%} for bending angles from 90 to 130 degrees and for a radius of curvature from 2 to 10 mm. Preliminary measurements for a detector with 2×2×21 mm3 LSO scintillators and a Hamamatsu R5900-C8 PS-PMT reveal good DOI measurement capability with this design, the measured DOI resolution ranging from 4.2 to 6 mm. It also provides excellent crystal identification and coincidence timing performance. The attenuation and scatter effects introduced by using optical fibers were also studied.",
author = "Yiping Shao and Cherry, {Simon R}",
year = "1999",
language = "English (US)",
isbn = "0780350227",
volume = "3",
pages = "1440--1444",
booktitle = "IEEE Nuclear Science Symposium and Medical Imaging Conference",
publisher = "IEEE",

}

TY - CHAP

T1 - Study of depth of interaction measurement using bent optical fibers

AU - Shao, Yiping

AU - Cherry, Simon R

PY - 1999

Y1 - 1999

N2 - Depth of interaction (DOI) measurement is an important capability for a detector suitable for use in a small PET scanner designed for breast imaging or small animal imaging. We have investigated a different scheme to determine DOI by using a position sensitive PMT (PS-PMT) at one end of an LSO crystal array for positioning and timing, and a single channel PMT connected to the other end through bent optical fibers with the ratio of the two signals to determine DOI. The main advantage of this approach is that both the PS-PMT and PMT can provide high signal-to-noise ratio outputs (improving DOI resolution) and that all technologies are available with easy readout electronics. Therefore, the design permits a relatively simple and practical solution to measure DOI while still maintaining good detector performance. We have successfully bent optical fibers, with a light loss due to fiber bending less than 10% for bending angles from 90 to 130 degrees and for a radius of curvature from 2 to 10 mm. Preliminary measurements for a detector with 2×2×21 mm3 LSO scintillators and a Hamamatsu R5900-C8 PS-PMT reveal good DOI measurement capability with this design, the measured DOI resolution ranging from 4.2 to 6 mm. It also provides excellent crystal identification and coincidence timing performance. The attenuation and scatter effects introduced by using optical fibers were also studied.

AB - Depth of interaction (DOI) measurement is an important capability for a detector suitable for use in a small PET scanner designed for breast imaging or small animal imaging. We have investigated a different scheme to determine DOI by using a position sensitive PMT (PS-PMT) at one end of an LSO crystal array for positioning and timing, and a single channel PMT connected to the other end through bent optical fibers with the ratio of the two signals to determine DOI. The main advantage of this approach is that both the PS-PMT and PMT can provide high signal-to-noise ratio outputs (improving DOI resolution) and that all technologies are available with easy readout electronics. Therefore, the design permits a relatively simple and practical solution to measure DOI while still maintaining good detector performance. We have successfully bent optical fibers, with a light loss due to fiber bending less than 10% for bending angles from 90 to 130 degrees and for a radius of curvature from 2 to 10 mm. Preliminary measurements for a detector with 2×2×21 mm3 LSO scintillators and a Hamamatsu R5900-C8 PS-PMT reveal good DOI measurement capability with this design, the measured DOI resolution ranging from 4.2 to 6 mm. It also provides excellent crystal identification and coincidence timing performance. The attenuation and scatter effects introduced by using optical fibers were also studied.

UR - http://www.scopus.com/inward/record.url?scp=0032597037&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032597037&partnerID=8YFLogxK

M3 - Chapter

SN - 0780350227

VL - 3

SP - 1440

EP - 1444

BT - IEEE Nuclear Science Symposium and Medical Imaging Conference

PB - IEEE

CY - Piscataway, NJ, United States

ER -