Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation

Nicolas L. Young, Michael C. Sisto, Meggie N. Young, Patrick G. Grant, David W. Killilea, Latasha LaMotte, Kuang Jen J Wu, Carlito B Lebrilla

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Here we report the design, implementation, and initial use of an asymmetric steady-state continuous dual-nanospray ion source. This new source design consists of two independently controlled and continuously operating nanospray interfaces with funnel shaped counter electrodes. A steady-state ion mixing region combines the ions from the two sources into a single ion beam in the intermediate region after ion extraction from the nano-spray sources but before the bulk of the pressure gradient of the vacuum interface. With this design we have achieved robust mixing of ions with no loss of duty cycle and remarkable ionization characteristics that appear entirely noncompetitive and potentially beneficial. This allows continuous introduction of internal mass calibration ions during a liquid chromatography-mass spectrometric analysis. This in turn allows for recalibration of individual spectra yielding sub part per million mass accuracy throughout the run. The steady-state approach presented here has several advantages over previous approaches. Since neither the voltage nor positions of the sprayers are changed, the nanospray has greater spray stability. The ions produced by the analyte sprayer are continuously sampled, as opposed to time-sharing which necessitates that the analyte ion stream be interrupted for some part of the duty cycle. There are no moving parts, no rapid changes to high voltages requiring additional control electronics, and no need for completely separate vacuum interfaces and the associated complexity. The sprayers are independently controlled and do not exhibit competition or mutual ionization suppression. This novel source has been implemented with a Bruker Apex II 9.4 T FTICR with a modified Apollo electrospray ion source as part of a nanoflow liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry analysis platform. Because of the low cost of implementation, the new source could potentially be applied to other forms of mass spectrometry, such as electrospray ioruzation-time-of-flight (ESI-TOF), which can benefit from internal mass calibration.

Original languageEnglish (US)
Pages (from-to)5711-5718
Number of pages8
JournalAnalytical Chemistry
Volume79
Issue number15
DOIs
StatePublished - Aug 1 2007

Fingerprint

Ion sources
Ions
Liquid chromatography
Ionization
Mass spectrometry
Calibration
Vacuum
Cyclotron resonance
Electric potential
Pressure gradient
Ion beams
Fourier transforms
Electronic equipment
Electrodes
Costs

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Young, N. L., Sisto, M. C., Young, M. N., Grant, P. G., Killilea, D. W., LaMotte, L., ... Lebrilla, C. B. (2007). Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation. Analytical Chemistry, 79(15), 5711-5718. https://doi.org/10.1021/ac070446z

Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation. / Young, Nicolas L.; Sisto, Michael C.; Young, Meggie N.; Grant, Patrick G.; Killilea, David W.; LaMotte, Latasha; Wu, Kuang Jen J; Lebrilla, Carlito B.

In: Analytical Chemistry, Vol. 79, No. 15, 01.08.2007, p. 5711-5718.

Research output: Contribution to journalArticle

Young, NL, Sisto, MC, Young, MN, Grant, PG, Killilea, DW, LaMotte, L, Wu, KJJ & Lebrilla, CB 2007, 'Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation', Analytical Chemistry, vol. 79, no. 15, pp. 5711-5718. https://doi.org/10.1021/ac070446z
Young, Nicolas L. ; Sisto, Michael C. ; Young, Meggie N. ; Grant, Patrick G. ; Killilea, David W. ; LaMotte, Latasha ; Wu, Kuang Jen J ; Lebrilla, Carlito B. / Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation. In: Analytical Chemistry. 2007 ; Vol. 79, No. 15. pp. 5711-5718.
@article{c429f3b2e647444d8e2bf0719a7e3ae0,
title = "Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation",
abstract = "Here we report the design, implementation, and initial use of an asymmetric steady-state continuous dual-nanospray ion source. This new source design consists of two independently controlled and continuously operating nanospray interfaces with funnel shaped counter electrodes. A steady-state ion mixing region combines the ions from the two sources into a single ion beam in the intermediate region after ion extraction from the nano-spray sources but before the bulk of the pressure gradient of the vacuum interface. With this design we have achieved robust mixing of ions with no loss of duty cycle and remarkable ionization characteristics that appear entirely noncompetitive and potentially beneficial. This allows continuous introduction of internal mass calibration ions during a liquid chromatography-mass spectrometric analysis. This in turn allows for recalibration of individual spectra yielding sub part per million mass accuracy throughout the run. The steady-state approach presented here has several advantages over previous approaches. Since neither the voltage nor positions of the sprayers are changed, the nanospray has greater spray stability. The ions produced by the analyte sprayer are continuously sampled, as opposed to time-sharing which necessitates that the analyte ion stream be interrupted for some part of the duty cycle. There are no moving parts, no rapid changes to high voltages requiring additional control electronics, and no need for completely separate vacuum interfaces and the associated complexity. The sprayers are independently controlled and do not exhibit competition or mutual ionization suppression. This novel source has been implemented with a Bruker Apex II 9.4 T FTICR with a modified Apollo electrospray ion source as part of a nanoflow liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry analysis platform. Because of the low cost of implementation, the new source could potentially be applied to other forms of mass spectrometry, such as electrospray ioruzation-time-of-flight (ESI-TOF), which can benefit from internal mass calibration.",
author = "Young, {Nicolas L.} and Sisto, {Michael C.} and Young, {Meggie N.} and Grant, {Patrick G.} and Killilea, {David W.} and Latasha LaMotte and Wu, {Kuang Jen J} and Lebrilla, {Carlito B}",
year = "2007",
month = "8",
day = "1",
doi = "10.1021/ac070446z",
language = "English (US)",
volume = "79",
pages = "5711--5718",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "15",

}

TY - JOUR

T1 - Steady-state asymmetric nanospray dual ion source for accurate mass determination within a chromatographic separation

AU - Young, Nicolas L.

AU - Sisto, Michael C.

AU - Young, Meggie N.

AU - Grant, Patrick G.

AU - Killilea, David W.

AU - LaMotte, Latasha

AU - Wu, Kuang Jen J

AU - Lebrilla, Carlito B

PY - 2007/8/1

Y1 - 2007/8/1

N2 - Here we report the design, implementation, and initial use of an asymmetric steady-state continuous dual-nanospray ion source. This new source design consists of two independently controlled and continuously operating nanospray interfaces with funnel shaped counter electrodes. A steady-state ion mixing region combines the ions from the two sources into a single ion beam in the intermediate region after ion extraction from the nano-spray sources but before the bulk of the pressure gradient of the vacuum interface. With this design we have achieved robust mixing of ions with no loss of duty cycle and remarkable ionization characteristics that appear entirely noncompetitive and potentially beneficial. This allows continuous introduction of internal mass calibration ions during a liquid chromatography-mass spectrometric analysis. This in turn allows for recalibration of individual spectra yielding sub part per million mass accuracy throughout the run. The steady-state approach presented here has several advantages over previous approaches. Since neither the voltage nor positions of the sprayers are changed, the nanospray has greater spray stability. The ions produced by the analyte sprayer are continuously sampled, as opposed to time-sharing which necessitates that the analyte ion stream be interrupted for some part of the duty cycle. There are no moving parts, no rapid changes to high voltages requiring additional control electronics, and no need for completely separate vacuum interfaces and the associated complexity. The sprayers are independently controlled and do not exhibit competition or mutual ionization suppression. This novel source has been implemented with a Bruker Apex II 9.4 T FTICR with a modified Apollo electrospray ion source as part of a nanoflow liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry analysis platform. Because of the low cost of implementation, the new source could potentially be applied to other forms of mass spectrometry, such as electrospray ioruzation-time-of-flight (ESI-TOF), which can benefit from internal mass calibration.

AB - Here we report the design, implementation, and initial use of an asymmetric steady-state continuous dual-nanospray ion source. This new source design consists of two independently controlled and continuously operating nanospray interfaces with funnel shaped counter electrodes. A steady-state ion mixing region combines the ions from the two sources into a single ion beam in the intermediate region after ion extraction from the nano-spray sources but before the bulk of the pressure gradient of the vacuum interface. With this design we have achieved robust mixing of ions with no loss of duty cycle and remarkable ionization characteristics that appear entirely noncompetitive and potentially beneficial. This allows continuous introduction of internal mass calibration ions during a liquid chromatography-mass spectrometric analysis. This in turn allows for recalibration of individual spectra yielding sub part per million mass accuracy throughout the run. The steady-state approach presented here has several advantages over previous approaches. Since neither the voltage nor positions of the sprayers are changed, the nanospray has greater spray stability. The ions produced by the analyte sprayer are continuously sampled, as opposed to time-sharing which necessitates that the analyte ion stream be interrupted for some part of the duty cycle. There are no moving parts, no rapid changes to high voltages requiring additional control electronics, and no need for completely separate vacuum interfaces and the associated complexity. The sprayers are independently controlled and do not exhibit competition or mutual ionization suppression. This novel source has been implemented with a Bruker Apex II 9.4 T FTICR with a modified Apollo electrospray ion source as part of a nanoflow liquid chromatography-Fourier transform ion cyclotron resonance mass spectrometry analysis platform. Because of the low cost of implementation, the new source could potentially be applied to other forms of mass spectrometry, such as electrospray ioruzation-time-of-flight (ESI-TOF), which can benefit from internal mass calibration.

UR - http://www.scopus.com/inward/record.url?scp=34547738409&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547738409&partnerID=8YFLogxK

U2 - 10.1021/ac070446z

DO - 10.1021/ac070446z

M3 - Article

C2 - 17614364

AN - SCOPUS:34547738409

VL - 79

SP - 5711

EP - 5718

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 15

ER -