Abstract

In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. We derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, we show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.

Original languageEnglish (US)
Pages (from-to)185-198
Number of pages14
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume41
Issue number2
DOIs
StatePublished - Mar 1994
Externally publishedYes

Fingerprint

laminar flow
Laminar flow
statistical analysis
blood
Statistical methods
Blood
Acoustic wave velocity
Autocorrelation
Ultrasonics
Particle size
Flow rate
Statistics
Viscosity
Fluids
intervals
transit time
pulses
autocorrelation
flow velocity
statistics

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Acoustics and Ultrasonics

Cite this

Statistical analysis of the received signal from blood during laminar flow. / Ferrara, Katherine W.; Algazi, V. Ralph.

In: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 41, No. 2, 03.1994, p. 185-198.

Research output: Contribution to journalArticle

@article{9dbcd40ca131435db5a25b52a328e37e,
title = "Statistical analysis of the received signal from blood during laminar flow",
abstract = "In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. We derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, we show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.",
author = "Ferrara, {Katherine W.} and Algazi, {V. Ralph}",
year = "1994",
month = "3",
doi = "10.1109/58.279131",
language = "English (US)",
volume = "41",
pages = "185--198",
journal = "IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control",
issn = "0885-3010",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "2",

}

TY - JOUR

T1 - Statistical analysis of the received signal from blood during laminar flow

AU - Ferrara, Katherine W.

AU - Algazi, V. Ralph

PY - 1994/3

Y1 - 1994/3

N2 - In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. We derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, we show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.

AB - In order to determine the limiting velocity resolution that can be achieved using ultrasound, and to provide a model which can be generalized for the analysis of disturbed flow, a theoretical and experimental evaluation of the statistics of the received signal from laminar flow following the transmission of a train of short pulses is presented. We derive the autocorrelation function and determine the length of the correlated signal for various flow rates, comparing experimental measurements to theoretical predictions. High resolution experimental RF M-mode images are used to verify the theoretical model. Using a fluid with a density, viscosity, volume concentration, particle size, and speed of sound which is similar to that of blood, we show that the signal remains correlated for a long interval under many conditions of clinical interest. Including a comparison with experimental data, the effect of the lateral transit time through the sample volume and the axial velocity spread within the sample volume on the correlation of the received signal is evaluated. When a significant range of velocity components is present within the sample volume, this range is the limiting factor in the length of the correlated signal interval. Therefore, the use of a wideband signal, which reduces the sample volume size, produces a returned signal that may be correlated for a larger number of pulses, or for a longer time.

UR - http://www.scopus.com/inward/record.url?scp=0028396589&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028396589&partnerID=8YFLogxK

U2 - 10.1109/58.279131

DO - 10.1109/58.279131

M3 - Article

VL - 41

SP - 185

EP - 198

JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

SN - 0885-3010

IS - 2

ER -