Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT

Stefan Siegel, Robert W. Silverman, Yiping Shao, Simon R Cherry

Research output: Contribution to journalArticle

224 Citations (Scopus)

Abstract

Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8×8 array of individual scintillators (2×2×10 mm BGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 64 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found that the preamplifier circuit noise contributed the most to the degradation of the detector's spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.

Original languageEnglish (US)
Pages (from-to)1634-1641
Number of pages8
JournalIEEE Transactions on Nuclear Science
Volume43
Issue number3 PART 2
DOIs
StatePublished - 1996

Fingerprint

Phosphors
scintillation counters
division
readout
Photomultipliers
Imaging techniques
Networks (circuits)
preamplifiers
photomultiplier tubes
Detectors
Gamma rays
detectors
impedance
gamma rays
Operational amplifiers
Crosstalk
Resistors
Optical fibers
crosstalk
resistors

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Nuclear Energy and Engineering

Cite this

Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT. / Siegel, Stefan; Silverman, Robert W.; Shao, Yiping; Cherry, Simon R.

In: IEEE Transactions on Nuclear Science, Vol. 43, No. 3 PART 2, 1996, p. 1634-1641.

Research output: Contribution to journalArticle

Siegel, Stefan ; Silverman, Robert W. ; Shao, Yiping ; Cherry, Simon R. / Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT. In: IEEE Transactions on Nuclear Science. 1996 ; Vol. 43, No. 3 PART 2. pp. 1634-1641.
@article{bf055e27e2c84e128351c2c8ff018144,
title = "Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT",
abstract = "Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8×8 array of individual scintillators (2×2×10 mm BGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 64 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found that the preamplifier circuit noise contributed the most to the degradation of the detector's spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.",
author = "Stefan Siegel and Silverman, {Robert W.} and Yiping Shao and Cherry, {Simon R}",
year = "1996",
doi = "10.1109/23.507162",
language = "English (US)",
volume = "43",
pages = "1634--1641",
journal = "IEEE Transactions on Nuclear Science",
issn = "0018-9499",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3 PART 2",

}

TY - JOUR

T1 - Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT

AU - Siegel, Stefan

AU - Silverman, Robert W.

AU - Shao, Yiping

AU - Cherry, Simon R

PY - 1996

Y1 - 1996

N2 - Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8×8 array of individual scintillators (2×2×10 mm BGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 64 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found that the preamplifier circuit noise contributed the most to the degradation of the detector's spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.

AB - Three simple charge division circuits were assembled and tested as 2-D position encoding readouts for multi-channel photomultiplier tubes (MC-PMT). They were evaluated with an 8×8 array of individual scintillators (2×2×10 mm BGO) coupled to a 64 channel MC-PMT (Philips XP1722) via 25 cm long, 2 mm diameter, double clad, optical fibers (Kuraray). This type of gamma-ray imaging detector has many potential applications in medical and industrial imaging. Though independent channel readout would allow for the discrimination of scatter within the array, and higher count rates, it would also require an excessive amount of supporting electronics. This is especially true for systems comprised of many MC-PMTs. In this study, the number of channels being read out was reduced from 64 to 4 using three different simple resistor networks. These circuits take advantage of the discretized nature of the scintillator array, the low interchannel crosstalk of the MC-PMT and low input impedance current-sensitive preamplifiers. For each circuit, the scintillator identification accuracy was compared. The identification accuracy as a function of deposited energy was also determined by exposure to various gamma-ray emitters. It was found that the preamplifier circuit noise contributed the most to the degradation of the detector's spatial response so several low noise op amps were evaluated. It was also determined that keeping the preamplifier input impedance small was necessary for accurate positioning. The coincidence timing resolution of the detector (15 ns) is only slightly degraded by the readout circuit.

UR - http://www.scopus.com/inward/record.url?scp=0030164341&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030164341&partnerID=8YFLogxK

U2 - 10.1109/23.507162

DO - 10.1109/23.507162

M3 - Article

AN - SCOPUS:0030164341

VL - 43

SP - 1634

EP - 1641

JO - IEEE Transactions on Nuclear Science

JF - IEEE Transactions on Nuclear Science

SN - 0018-9499

IS - 3 PART 2

ER -