Signal and noise properties of position-sensitive avalanche photodiodes

Yongfeng Yang, Yibao Wu, Richard Farrell, Purushottam A. Dokhale, Kanai S. Shah, Simon R Cherry

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

After many years of development, position-sensitive avalanche photodiodes (PSAPDs) are now being incorporated into a range of scintillation detector systems, including those used in high-resolution small-animal PET and PET/MR scanners. In this work, the signal, noise, signal-to-noise ratio (SNR), flood histogram and timing resolution were measured for lutetium oxyorthosilicate (LSO) scintillator arrays coupled to PSAPDs ranging in size from 10 to 20 mm, and the optimum bias voltage and working temperature were determined. Variations in the SNR performance of PSAPDs with the same dimensions were small, but the SNR decreased significantly with increasing PSAPD size and increasing temperature. Smaller PSAPDs (10 mm and 15 mm in width) produced acceptable flood histograms at 24 °C, and cooling lower than 16 °C produced little improvement. The optimum bias voltage was about 25 V below the break down voltage. The larger 20 mm PSAPDs have lower SNR and require cooling to 0-7 °C for acceptable performance. The optimum bias voltage is also lower (35 V or more below the break down voltage depending on the temperature). Significant changes in the timing resolution were observed as the bias voltage and temperature varied. Higher bias voltages provided better timing resolution. The best timing resolution obtained for individual crystals was 2.8 ns and 3.3 ns for the 10 mm and 15 mm PSAPDs, respectively. The results of this work provide useful guidance for selecting the bias voltage and working temperature for scintillation detectors that incorporate PSAPDs as the photodetector.

Original languageEnglish (US)
Article number011
Pages (from-to)6327-6336
Number of pages10
JournalPhysics in Medicine and Biology
Volume56
Issue number19
DOIs
StatePublished - 2011

Fingerprint

Avalanches
Signal-To-Noise Ratio
Temperature
Noise

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Signal and noise properties of position-sensitive avalanche photodiodes. / Yang, Yongfeng; Wu, Yibao; Farrell, Richard; Dokhale, Purushottam A.; Shah, Kanai S.; Cherry, Simon R.

In: Physics in Medicine and Biology, Vol. 56, No. 19, 011, 2011, p. 6327-6336.

Research output: Contribution to journalArticle

Yang, Yongfeng ; Wu, Yibao ; Farrell, Richard ; Dokhale, Purushottam A. ; Shah, Kanai S. ; Cherry, Simon R. / Signal and noise properties of position-sensitive avalanche photodiodes. In: Physics in Medicine and Biology. 2011 ; Vol. 56, No. 19. pp. 6327-6336.
@article{8cde344f15df4b33b3fd3278d2930ca1,
title = "Signal and noise properties of position-sensitive avalanche photodiodes",
abstract = "After many years of development, position-sensitive avalanche photodiodes (PSAPDs) are now being incorporated into a range of scintillation detector systems, including those used in high-resolution small-animal PET and PET/MR scanners. In this work, the signal, noise, signal-to-noise ratio (SNR), flood histogram and timing resolution were measured for lutetium oxyorthosilicate (LSO) scintillator arrays coupled to PSAPDs ranging in size from 10 to 20 mm, and the optimum bias voltage and working temperature were determined. Variations in the SNR performance of PSAPDs with the same dimensions were small, but the SNR decreased significantly with increasing PSAPD size and increasing temperature. Smaller PSAPDs (10 mm and 15 mm in width) produced acceptable flood histograms at 24 °C, and cooling lower than 16 °C produced little improvement. The optimum bias voltage was about 25 V below the break down voltage. The larger 20 mm PSAPDs have lower SNR and require cooling to 0-7 °C for acceptable performance. The optimum bias voltage is also lower (35 V or more below the break down voltage depending on the temperature). Significant changes in the timing resolution were observed as the bias voltage and temperature varied. Higher bias voltages provided better timing resolution. The best timing resolution obtained for individual crystals was 2.8 ns and 3.3 ns for the 10 mm and 15 mm PSAPDs, respectively. The results of this work provide useful guidance for selecting the bias voltage and working temperature for scintillation detectors that incorporate PSAPDs as the photodetector.",
author = "Yongfeng Yang and Yibao Wu and Richard Farrell and Dokhale, {Purushottam A.} and Shah, {Kanai S.} and Cherry, {Simon R}",
year = "2011",
doi = "10.1088/0031-9155/56/19/011",
language = "English (US)",
volume = "56",
pages = "6327--6336",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "19",

}

TY - JOUR

T1 - Signal and noise properties of position-sensitive avalanche photodiodes

AU - Yang, Yongfeng

AU - Wu, Yibao

AU - Farrell, Richard

AU - Dokhale, Purushottam A.

AU - Shah, Kanai S.

AU - Cherry, Simon R

PY - 2011

Y1 - 2011

N2 - After many years of development, position-sensitive avalanche photodiodes (PSAPDs) are now being incorporated into a range of scintillation detector systems, including those used in high-resolution small-animal PET and PET/MR scanners. In this work, the signal, noise, signal-to-noise ratio (SNR), flood histogram and timing resolution were measured for lutetium oxyorthosilicate (LSO) scintillator arrays coupled to PSAPDs ranging in size from 10 to 20 mm, and the optimum bias voltage and working temperature were determined. Variations in the SNR performance of PSAPDs with the same dimensions were small, but the SNR decreased significantly with increasing PSAPD size and increasing temperature. Smaller PSAPDs (10 mm and 15 mm in width) produced acceptable flood histograms at 24 °C, and cooling lower than 16 °C produced little improvement. The optimum bias voltage was about 25 V below the break down voltage. The larger 20 mm PSAPDs have lower SNR and require cooling to 0-7 °C for acceptable performance. The optimum bias voltage is also lower (35 V or more below the break down voltage depending on the temperature). Significant changes in the timing resolution were observed as the bias voltage and temperature varied. Higher bias voltages provided better timing resolution. The best timing resolution obtained for individual crystals was 2.8 ns and 3.3 ns for the 10 mm and 15 mm PSAPDs, respectively. The results of this work provide useful guidance for selecting the bias voltage and working temperature for scintillation detectors that incorporate PSAPDs as the photodetector.

AB - After many years of development, position-sensitive avalanche photodiodes (PSAPDs) are now being incorporated into a range of scintillation detector systems, including those used in high-resolution small-animal PET and PET/MR scanners. In this work, the signal, noise, signal-to-noise ratio (SNR), flood histogram and timing resolution were measured for lutetium oxyorthosilicate (LSO) scintillator arrays coupled to PSAPDs ranging in size from 10 to 20 mm, and the optimum bias voltage and working temperature were determined. Variations in the SNR performance of PSAPDs with the same dimensions were small, but the SNR decreased significantly with increasing PSAPD size and increasing temperature. Smaller PSAPDs (10 mm and 15 mm in width) produced acceptable flood histograms at 24 °C, and cooling lower than 16 °C produced little improvement. The optimum bias voltage was about 25 V below the break down voltage. The larger 20 mm PSAPDs have lower SNR and require cooling to 0-7 °C for acceptable performance. The optimum bias voltage is also lower (35 V or more below the break down voltage depending on the temperature). Significant changes in the timing resolution were observed as the bias voltage and temperature varied. Higher bias voltages provided better timing resolution. The best timing resolution obtained for individual crystals was 2.8 ns and 3.3 ns for the 10 mm and 15 mm PSAPDs, respectively. The results of this work provide useful guidance for selecting the bias voltage and working temperature for scintillation detectors that incorporate PSAPDs as the photodetector.

UR - http://www.scopus.com/inward/record.url?scp=80053201264&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80053201264&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/56/19/011

DO - 10.1088/0031-9155/56/19/011

M3 - Article

VL - 56

SP - 6327

EP - 6336

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 19

M1 - 011

ER -