Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine

Natalia Vasylieva, Bogdan Barnych, Amy Rand, Bora Inceoglu, Shirley J. Gee, Bruce D. Hammock

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Tetramethylenedisulfotetramine (TETS, tetramine) is a formerly used and highly neurotoxic rodenticide. Its lethality, recent history of intentional use for mass poisoning, and the absence of a known antidote raise public health concerns. Therefore, rapid, high throughput, and sensitive methods for detection and quantification of TETS are critical. Instrumental analysis method such as GC/MS is sensitive but not rapid or high throughput. Therefore, an immunoassay selective to TETS was developed. The assay shows an IC50 of 4.5 ± 1.2 ng/mL, with a limit of detection of 0.2 ng/mL, comparable to GC/MS. Performance of the immunoassay was demonstrated by a recovery study using known concentrations of TETS spiked into buffer and human and mouse serum matrices giving recoveries in the range of 80-120%. The assay demonstrated good correlation in TETS recovery with established GC/MS analysis. The immunoassay was then used to quantify TETS concentration in the serum of mice exposed to 2× LD50 dose of TETS and to monitor kinetics of TETS clearance from blood over a short period of time. TETS concentration in the serum reached 150 ng/mL without significant change over 4 h post-treatment. Results obtained with the immunoassay had good correlation with GC/MS analysis. Overall, this immunoassay is an important tool to rapidly detect and quantify levels of TETS from biological samples with high sensitivity. The assay can be adapted to multiple formats including field or hospital use.

Original languageEnglish (US)
Pages (from-to)5612-5619
Number of pages8
JournalAnalytical Chemistry
Volume89
Issue number10
DOIs
StatePublished - May 16 2017

Fingerprint

tetramethylenedisulfotetramine
Neurotoxins
Assays
Recovery
Rodenticides
Throughput
Antidotes
Public health
Buffers
Blood
Kinetics

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Vasylieva, N., Barnych, B., Rand, A., Inceoglu, B., Gee, S. J., & Hammock, B. D. (2017). Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine. Analytical Chemistry, 89(10), 5612-5619. https://doi.org/10.1021/acs.analchem.7b00846

Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine. / Vasylieva, Natalia; Barnych, Bogdan; Rand, Amy; Inceoglu, Bora; Gee, Shirley J.; Hammock, Bruce D.

In: Analytical Chemistry, Vol. 89, No. 10, 16.05.2017, p. 5612-5619.

Research output: Contribution to journalArticle

Vasylieva, N, Barnych, B, Rand, A, Inceoglu, B, Gee, SJ & Hammock, BD 2017, 'Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine', Analytical Chemistry, vol. 89, no. 10, pp. 5612-5619. https://doi.org/10.1021/acs.analchem.7b00846
Vasylieva, Natalia ; Barnych, Bogdan ; Rand, Amy ; Inceoglu, Bora ; Gee, Shirley J. ; Hammock, Bruce D. / Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine. In: Analytical Chemistry. 2017 ; Vol. 89, No. 10. pp. 5612-5619.
@article{7b8f303681f84c22bd5cb1a1f7a1030d,
title = "Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine",
abstract = "Tetramethylenedisulfotetramine (TETS, tetramine) is a formerly used and highly neurotoxic rodenticide. Its lethality, recent history of intentional use for mass poisoning, and the absence of a known antidote raise public health concerns. Therefore, rapid, high throughput, and sensitive methods for detection and quantification of TETS are critical. Instrumental analysis method such as GC/MS is sensitive but not rapid or high throughput. Therefore, an immunoassay selective to TETS was developed. The assay shows an IC50 of 4.5 ± 1.2 ng/mL, with a limit of detection of 0.2 ng/mL, comparable to GC/MS. Performance of the immunoassay was demonstrated by a recovery study using known concentrations of TETS spiked into buffer and human and mouse serum matrices giving recoveries in the range of 80-120{\%}. The assay demonstrated good correlation in TETS recovery with established GC/MS analysis. The immunoassay was then used to quantify TETS concentration in the serum of mice exposed to 2× LD50 dose of TETS and to monitor kinetics of TETS clearance from blood over a short period of time. TETS concentration in the serum reached 150 ng/mL without significant change over 4 h post-treatment. Results obtained with the immunoassay had good correlation with GC/MS analysis. Overall, this immunoassay is an important tool to rapidly detect and quantify levels of TETS from biological samples with high sensitivity. The assay can be adapted to multiple formats including field or hospital use.",
author = "Natalia Vasylieva and Bogdan Barnych and Amy Rand and Bora Inceoglu and Gee, {Shirley J.} and Hammock, {Bruce D.}",
year = "2017",
month = "5",
day = "16",
doi = "10.1021/acs.analchem.7b00846",
language = "English (US)",
volume = "89",
pages = "5612--5619",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "10",

}

TY - JOUR

T1 - Sensitive Immunoassay for Detection and Quantification of the Neurotoxin, Tetramethylenedisulfotetramine

AU - Vasylieva, Natalia

AU - Barnych, Bogdan

AU - Rand, Amy

AU - Inceoglu, Bora

AU - Gee, Shirley J.

AU - Hammock, Bruce D.

PY - 2017/5/16

Y1 - 2017/5/16

N2 - Tetramethylenedisulfotetramine (TETS, tetramine) is a formerly used and highly neurotoxic rodenticide. Its lethality, recent history of intentional use for mass poisoning, and the absence of a known antidote raise public health concerns. Therefore, rapid, high throughput, and sensitive methods for detection and quantification of TETS are critical. Instrumental analysis method such as GC/MS is sensitive but not rapid or high throughput. Therefore, an immunoassay selective to TETS was developed. The assay shows an IC50 of 4.5 ± 1.2 ng/mL, with a limit of detection of 0.2 ng/mL, comparable to GC/MS. Performance of the immunoassay was demonstrated by a recovery study using known concentrations of TETS spiked into buffer and human and mouse serum matrices giving recoveries in the range of 80-120%. The assay demonstrated good correlation in TETS recovery with established GC/MS analysis. The immunoassay was then used to quantify TETS concentration in the serum of mice exposed to 2× LD50 dose of TETS and to monitor kinetics of TETS clearance from blood over a short period of time. TETS concentration in the serum reached 150 ng/mL without significant change over 4 h post-treatment. Results obtained with the immunoassay had good correlation with GC/MS analysis. Overall, this immunoassay is an important tool to rapidly detect and quantify levels of TETS from biological samples with high sensitivity. The assay can be adapted to multiple formats including field or hospital use.

AB - Tetramethylenedisulfotetramine (TETS, tetramine) is a formerly used and highly neurotoxic rodenticide. Its lethality, recent history of intentional use for mass poisoning, and the absence of a known antidote raise public health concerns. Therefore, rapid, high throughput, and sensitive methods for detection and quantification of TETS are critical. Instrumental analysis method such as GC/MS is sensitive but not rapid or high throughput. Therefore, an immunoassay selective to TETS was developed. The assay shows an IC50 of 4.5 ± 1.2 ng/mL, with a limit of detection of 0.2 ng/mL, comparable to GC/MS. Performance of the immunoassay was demonstrated by a recovery study using known concentrations of TETS spiked into buffer and human and mouse serum matrices giving recoveries in the range of 80-120%. The assay demonstrated good correlation in TETS recovery with established GC/MS analysis. The immunoassay was then used to quantify TETS concentration in the serum of mice exposed to 2× LD50 dose of TETS and to monitor kinetics of TETS clearance from blood over a short period of time. TETS concentration in the serum reached 150 ng/mL without significant change over 4 h post-treatment. Results obtained with the immunoassay had good correlation with GC/MS analysis. Overall, this immunoassay is an important tool to rapidly detect and quantify levels of TETS from biological samples with high sensitivity. The assay can be adapted to multiple formats including field or hospital use.

UR - http://www.scopus.com/inward/record.url?scp=85020670850&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85020670850&partnerID=8YFLogxK

U2 - 10.1021/acs.analchem.7b00846

DO - 10.1021/acs.analchem.7b00846

M3 - Article

AN - SCOPUS:85020670850

VL - 89

SP - 5612

EP - 5619

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 10

ER -