SBRT targets that move with respiration

Sonja Dieterich, Olga Green, Jeremy Booth

Research output: Contribution to journalReview article

4 Citations (Scopus)

Abstract

The technology of treating SBRT targets that move with respiration has undergone profound changes over the last 20 years. This review article summarizes modern image guidance to localize the target in real-time to account for intra-fraction motion. The state-of-the art respiratory motion compensation techniques will be discussed, including the determination and application of appropriate margins. This includes compression, gating and breath-hold, including the use of audiovisual feedback to manage motion. Approaches to real-time tracking include the use of hybrid external-internal imaging to build a skin-to-tumor correlation, which can then be tracked with a mobile robot (CyberKnife Synchrony, clinical since 2003) as well as the use of non-ionizing electromagnetic tumor surrogate localization followed by real-time tracking with a moving MLC (in clinical trials in Europe and Australia). Lastly, the clinical application of real-time MRI soft-tissue imaging to deliver adaptive, iso-toxic treatments will be presented.

Original languageEnglish (US)
Pages (from-to)19-24
Number of pages6
JournalPhysica Medica
Volume56
DOIs
StatePublished - Dec 1 2018

Fingerprint

respiration
Respiration
tumors
Poisons
Electromagnetic Phenomena
robots
margins
Neoplasms
Clinical Trials
electromagnetism
Technology
Skin

Keywords

  • Dynamic MLC
  • Image-guided treatment
  • MRI linac
  • Respiratory motion management
  • SBRT

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Physics and Astronomy(all)

Cite this

SBRT targets that move with respiration. / Dieterich, Sonja; Green, Olga; Booth, Jeremy.

In: Physica Medica, Vol. 56, 01.12.2018, p. 19-24.

Research output: Contribution to journalReview article

Dieterich, Sonja ; Green, Olga ; Booth, Jeremy. / SBRT targets that move with respiration. In: Physica Medica. 2018 ; Vol. 56. pp. 19-24.
@article{864f9c56c8f449c786678a48582df048,
title = "SBRT targets that move with respiration",
abstract = "The technology of treating SBRT targets that move with respiration has undergone profound changes over the last 20 years. This review article summarizes modern image guidance to localize the target in real-time to account for intra-fraction motion. The state-of-the art respiratory motion compensation techniques will be discussed, including the determination and application of appropriate margins. This includes compression, gating and breath-hold, including the use of audiovisual feedback to manage motion. Approaches to real-time tracking include the use of hybrid external-internal imaging to build a skin-to-tumor correlation, which can then be tracked with a mobile robot (CyberKnife Synchrony, clinical since 2003) as well as the use of non-ionizing electromagnetic tumor surrogate localization followed by real-time tracking with a moving MLC (in clinical trials in Europe and Australia). Lastly, the clinical application of real-time MRI soft-tissue imaging to deliver adaptive, iso-toxic treatments will be presented.",
keywords = "Dynamic MLC, Image-guided treatment, MRI linac, Respiratory motion management, SBRT",
author = "Sonja Dieterich and Olga Green and Jeremy Booth",
year = "2018",
month = "12",
day = "1",
doi = "10.1016/j.ejmp.2018.10.021",
language = "English (US)",
volume = "56",
pages = "19--24",
journal = "Physica Medica",
issn = "1120-1797",
publisher = "Associazione Italiana di Fisica Medica",

}

TY - JOUR

T1 - SBRT targets that move with respiration

AU - Dieterich, Sonja

AU - Green, Olga

AU - Booth, Jeremy

PY - 2018/12/1

Y1 - 2018/12/1

N2 - The technology of treating SBRT targets that move with respiration has undergone profound changes over the last 20 years. This review article summarizes modern image guidance to localize the target in real-time to account for intra-fraction motion. The state-of-the art respiratory motion compensation techniques will be discussed, including the determination and application of appropriate margins. This includes compression, gating and breath-hold, including the use of audiovisual feedback to manage motion. Approaches to real-time tracking include the use of hybrid external-internal imaging to build a skin-to-tumor correlation, which can then be tracked with a mobile robot (CyberKnife Synchrony, clinical since 2003) as well as the use of non-ionizing electromagnetic tumor surrogate localization followed by real-time tracking with a moving MLC (in clinical trials in Europe and Australia). Lastly, the clinical application of real-time MRI soft-tissue imaging to deliver adaptive, iso-toxic treatments will be presented.

AB - The technology of treating SBRT targets that move with respiration has undergone profound changes over the last 20 years. This review article summarizes modern image guidance to localize the target in real-time to account for intra-fraction motion. The state-of-the art respiratory motion compensation techniques will be discussed, including the determination and application of appropriate margins. This includes compression, gating and breath-hold, including the use of audiovisual feedback to manage motion. Approaches to real-time tracking include the use of hybrid external-internal imaging to build a skin-to-tumor correlation, which can then be tracked with a mobile robot (CyberKnife Synchrony, clinical since 2003) as well as the use of non-ionizing electromagnetic tumor surrogate localization followed by real-time tracking with a moving MLC (in clinical trials in Europe and Australia). Lastly, the clinical application of real-time MRI soft-tissue imaging to deliver adaptive, iso-toxic treatments will be presented.

KW - Dynamic MLC

KW - Image-guided treatment

KW - MRI linac

KW - Respiratory motion management

KW - SBRT

UR - http://www.scopus.com/inward/record.url?scp=85056644094&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85056644094&partnerID=8YFLogxK

U2 - 10.1016/j.ejmp.2018.10.021

DO - 10.1016/j.ejmp.2018.10.021

M3 - Review article

C2 - 30527085

AN - SCOPUS:85056644094

VL - 56

SP - 19

EP - 24

JO - Physica Medica

JF - Physica Medica

SN - 1120-1797