Review on Ion Mobility Spectrometry. Part 2

Hyphenated methods and effects of experimental parameters

R. Cumeras, E. Figueras, Cristina E Davis, J. I. Baumbach, I. Gràcia

Research output: Contribution to journalReview article

58 Citations (Scopus)

Abstract

Ion Mobility Spectrometry (IMS) is a widely used and 'well-known' technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique. This journal is

Original languageEnglish (US)
Pages (from-to)1391-1410
Number of pages20
JournalAnalyst
Volume140
Issue number5
DOIs
StatePublished - Mar 7 2015

Fingerprint

Spectrometry
spectrometry
Spectrum Analysis
Ions
ion
effect
method
parameter
Equipment and Supplies
instrumentation
Mass spectrometry
electric field
Mass Spectrometry
mass spectrometry
Electric fields

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy
  • Electrochemistry
  • Biochemistry
  • Environmental Chemistry

Cite this

Review on Ion Mobility Spectrometry. Part 2 : Hyphenated methods and effects of experimental parameters. / Cumeras, R.; Figueras, E.; Davis, Cristina E; Baumbach, J. I.; Gràcia, I.

In: Analyst, Vol. 140, No. 5, 07.03.2015, p. 1391-1410.

Research output: Contribution to journalReview article

Cumeras, R. ; Figueras, E. ; Davis, Cristina E ; Baumbach, J. I. ; Gràcia, I. / Review on Ion Mobility Spectrometry. Part 2 : Hyphenated methods and effects of experimental parameters. In: Analyst. 2015 ; Vol. 140, No. 5. pp. 1391-1410.
@article{7b19fbef8c9f4a2fa075f43459a509d3,
title = "Review on Ion Mobility Spectrometry. Part 2: Hyphenated methods and effects of experimental parameters",
abstract = "Ion Mobility Spectrometry (IMS) is a widely used and 'well-known' technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique. This journal is",
author = "R. Cumeras and E. Figueras and Davis, {Cristina E} and Baumbach, {J. I.} and I. Gr{\`a}cia",
year = "2015",
month = "3",
day = "7",
doi = "10.1039/c4an01101e",
language = "English (US)",
volume = "140",
pages = "1391--1410",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "5",

}

TY - JOUR

T1 - Review on Ion Mobility Spectrometry. Part 2

T2 - Hyphenated methods and effects of experimental parameters

AU - Cumeras, R.

AU - Figueras, E.

AU - Davis, Cristina E

AU - Baumbach, J. I.

AU - Gràcia, I.

PY - 2015/3/7

Y1 - 2015/3/7

N2 - Ion Mobility Spectrometry (IMS) is a widely used and 'well-known' technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique. This journal is

AB - Ion Mobility Spectrometry (IMS) is a widely used and 'well-known' technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique. This journal is

UR - http://www.scopus.com/inward/record.url?scp=84923165870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84923165870&partnerID=8YFLogxK

U2 - 10.1039/c4an01101e

DO - 10.1039/c4an01101e

M3 - Review article

VL - 140

SP - 1391

EP - 1410

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 5

ER -