Retrograde cardiovascular angiography in infants, using a 3.6 French catheter

Mark D Parrish, Thomas P. Graham, Clyde W. Smith, Sandra Thompson

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Diagnostic retrograde arterial catheterization in infants and small children has been constrained by the risk of arterial thrombosis and the low flow rate of catheters less than #5 French. We performed retrograde arterial catheterization (percutaneous technique in 21 of 24 patients) on 24 infants and small children (median age 3 months, median weight 4.1 kg), using a 3.6 French preformed polyethylene catheter. Systemic heparinization was used. Among the group, we performed 23 aortograms, and 4 selective injections into a bronchial artery; all angiograms were of diagnostic quality. Injection rates ranged from 3 cc/sec to 10 cc/sec (median 5 cc/sec) with a peak developed pressure of 300 PSI to 900 PSI (median 700 PSI). No catheter-related complications were encountered during the study. Four of 24 patients developed a decreased pulse, noted immediately following the catheterization; however, pulses returned to normal within 24 hours, and late blood pressure assessment revealed no abnormalities in the catheterized leg. We now recommend this catheter for infants less than 10 kg when the following angiograms are required: 1. retrograde aortography (truncus arteriosus, pulmonary atresia, aortic stenosis, coarctation, coronary anomalies) 2. selective injections of bronchial arteries 3. retrograde catheterization of surgical shunts

Original languageEnglish (US)
Pages (from-to)225-230
Number of pages6
JournalPediatric Cardiology
Volume2
Issue number3
DOIs
StatePublished - Sep 1982
Externally publishedYes

Fingerprint

Catheterization
Angiography
Catheters
Bronchial Arteries
Injections
Truncus Arteriosus
Pulmonary Atresia
Aortography
Aortic Coarctation
Aortic Valve Stenosis
Polyethylene
Pulse
Leg
Thrombosis
Blood Pressure
Pressure
Weights and Measures

Keywords

  • Infants
  • Retrograde angiography

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Cardiology and Cardiovascular Medicine

Cite this

Retrograde cardiovascular angiography in infants, using a 3.6 French catheter. / Parrish, Mark D; Graham, Thomas P.; Smith, Clyde W.; Thompson, Sandra.

In: Pediatric Cardiology, Vol. 2, No. 3, 09.1982, p. 225-230.

Research output: Contribution to journalArticle

Parrish, Mark D ; Graham, Thomas P. ; Smith, Clyde W. ; Thompson, Sandra. / Retrograde cardiovascular angiography in infants, using a 3.6 French catheter. In: Pediatric Cardiology. 1982 ; Vol. 2, No. 3. pp. 225-230.
@article{eb71d2278f7844948fa447cf01faeb94,
title = "Retrograde cardiovascular angiography in infants, using a 3.6 French catheter",
abstract = "Diagnostic retrograde arterial catheterization in infants and small children has been constrained by the risk of arterial thrombosis and the low flow rate of catheters less than #5 French. We performed retrograde arterial catheterization (percutaneous technique in 21 of 24 patients) on 24 infants and small children (median age 3 months, median weight 4.1 kg), using a 3.6 French preformed polyethylene catheter. Systemic heparinization was used. Among the group, we performed 23 aortograms, and 4 selective injections into a bronchial artery; all angiograms were of diagnostic quality. Injection rates ranged from 3 cc/sec to 10 cc/sec (median 5 cc/sec) with a peak developed pressure of 300 PSI to 900 PSI (median 700 PSI). No catheter-related complications were encountered during the study. Four of 24 patients developed a decreased pulse, noted immediately following the catheterization; however, pulses returned to normal within 24 hours, and late blood pressure assessment revealed no abnormalities in the catheterized leg. We now recommend this catheter for infants less than 10 kg when the following angiograms are required: 1. retrograde aortography (truncus arteriosus, pulmonary atresia, aortic stenosis, coarctation, coronary anomalies) 2. selective injections of bronchial arteries 3. retrograde catheterization of surgical shunts",
keywords = "Infants, Retrograde angiography",
author = "Parrish, {Mark D} and Graham, {Thomas P.} and Smith, {Clyde W.} and Sandra Thompson",
year = "1982",
month = "9",
doi = "10.1007/BF02332113",
language = "English (US)",
volume = "2",
pages = "225--230",
journal = "Pediatric Cardiology",
issn = "0172-0643",
publisher = "Springer New York",
number = "3",

}

TY - JOUR

T1 - Retrograde cardiovascular angiography in infants, using a 3.6 French catheter

AU - Parrish, Mark D

AU - Graham, Thomas P.

AU - Smith, Clyde W.

AU - Thompson, Sandra

PY - 1982/9

Y1 - 1982/9

N2 - Diagnostic retrograde arterial catheterization in infants and small children has been constrained by the risk of arterial thrombosis and the low flow rate of catheters less than #5 French. We performed retrograde arterial catheterization (percutaneous technique in 21 of 24 patients) on 24 infants and small children (median age 3 months, median weight 4.1 kg), using a 3.6 French preformed polyethylene catheter. Systemic heparinization was used. Among the group, we performed 23 aortograms, and 4 selective injections into a bronchial artery; all angiograms were of diagnostic quality. Injection rates ranged from 3 cc/sec to 10 cc/sec (median 5 cc/sec) with a peak developed pressure of 300 PSI to 900 PSI (median 700 PSI). No catheter-related complications were encountered during the study. Four of 24 patients developed a decreased pulse, noted immediately following the catheterization; however, pulses returned to normal within 24 hours, and late blood pressure assessment revealed no abnormalities in the catheterized leg. We now recommend this catheter for infants less than 10 kg when the following angiograms are required: 1. retrograde aortography (truncus arteriosus, pulmonary atresia, aortic stenosis, coarctation, coronary anomalies) 2. selective injections of bronchial arteries 3. retrograde catheterization of surgical shunts

AB - Diagnostic retrograde arterial catheterization in infants and small children has been constrained by the risk of arterial thrombosis and the low flow rate of catheters less than #5 French. We performed retrograde arterial catheterization (percutaneous technique in 21 of 24 patients) on 24 infants and small children (median age 3 months, median weight 4.1 kg), using a 3.6 French preformed polyethylene catheter. Systemic heparinization was used. Among the group, we performed 23 aortograms, and 4 selective injections into a bronchial artery; all angiograms were of diagnostic quality. Injection rates ranged from 3 cc/sec to 10 cc/sec (median 5 cc/sec) with a peak developed pressure of 300 PSI to 900 PSI (median 700 PSI). No catheter-related complications were encountered during the study. Four of 24 patients developed a decreased pulse, noted immediately following the catheterization; however, pulses returned to normal within 24 hours, and late blood pressure assessment revealed no abnormalities in the catheterized leg. We now recommend this catheter for infants less than 10 kg when the following angiograms are required: 1. retrograde aortography (truncus arteriosus, pulmonary atresia, aortic stenosis, coarctation, coronary anomalies) 2. selective injections of bronchial arteries 3. retrograde catheterization of surgical shunts

KW - Infants

KW - Retrograde angiography

UR - http://www.scopus.com/inward/record.url?scp=0020000450&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020000450&partnerID=8YFLogxK

U2 - 10.1007/BF02332113

DO - 10.1007/BF02332113

M3 - Article

C2 - 7111056

AN - SCOPUS:0020000450

VL - 2

SP - 225

EP - 230

JO - Pediatric Cardiology

JF - Pediatric Cardiology

SN - 0172-0643

IS - 3

ER -