Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics

Ravi Jonnal, Omer P. Kocaoglu, Qiang Wang, Sangyeol Lee, Donald T. Miller

Research output: Contribution to journalArticle

58 Citations (Scopus)

Abstract

The cone photoreceptor's outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT's axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementationsof spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that- when combined with appropriate methods for filtering and unwrapping-it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings.

Original languageEnglish (US)
Pages (from-to)104-124
Number of pages21
JournalBiomedical Optics Express
Volume3
Issue number1
DOIs
StatePublished - Jan 1 2012
Externally publishedYes

Fingerprint

retina
Optical Coherence Tomography
adaptive optics
Retina
tomography
optics
Retinal Cone Photoreceptor Cells
cones
fovea
photoreceptors
Software
optical paths
eccentricity
stimuli
quantitative analysis
elongation
computer programs
sensitivity
cells
wavelengths

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Biotechnology

Cite this

Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics. / Jonnal, Ravi; Kocaoglu, Omer P.; Wang, Qiang; Lee, Sangyeol; Miller, Donald T.

In: Biomedical Optics Express, Vol. 3, No. 1, 01.01.2012, p. 104-124.

Research output: Contribution to journalArticle

Jonnal, Ravi ; Kocaoglu, Omer P. ; Wang, Qiang ; Lee, Sangyeol ; Miller, Donald T. / Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics. In: Biomedical Optics Express. 2012 ; Vol. 3, No. 1. pp. 104-124.
@article{7ae910cef001495db44c2444556542c3,
title = "Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics",
abstract = "The cone photoreceptor's outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT's axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementationsof spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that- when combined with appropriate methods for filtering and unwrapping-it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings.",
author = "Ravi Jonnal and Kocaoglu, {Omer P.} and Qiang Wang and Sangyeol Lee and Miller, {Donald T.}",
year = "2012",
month = "1",
day = "1",
doi = "10.1364/BOE.3.000104",
language = "English (US)",
volume = "3",
pages = "104--124",
journal = "Biomedical Optics Express",
issn = "2156-7085",
publisher = "The Optical Society",
number = "1",

}

TY - JOUR

T1 - Phase-sensitive imaging of the outer retina using optical coherence tomography and adaptive optics

AU - Jonnal, Ravi

AU - Kocaoglu, Omer P.

AU - Wang, Qiang

AU - Lee, Sangyeol

AU - Miller, Donald T.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - The cone photoreceptor's outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT's axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementationsof spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that- when combined with appropriate methods for filtering and unwrapping-it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings.

AB - The cone photoreceptor's outer segment (OS) experiences changes in optical path length, both in response to visible stimuli and as a matter of its daily course of renewal and shedding. These changes are of interest, to quantify function in healthy cells and assess dysfunction in diseased ones. While optical coherence tomography (OCT), combined with adaptive optics (AO), has permitted unprecedented three-dimensional resolution in the living retina, it has not generally been able to measure these OS dynamics, whose scale is smaller than OCT's axial resolution of a few microns. A possible solution is to take advantage of the phase information encoded in the OCT signal. Phase-sensitive implementationsof spectral-domain optical coherence tomography (SD-OCT) have been demonstrated, capable of resolving sample axial displacements much smaller than the imaging wavelength, but these have been limited to ex vivo samples. In this paper we present a novel technique for retrieving phase information from OCT volumes of the outer retina. The key component of our technique is quantification of phase differences within the retina. We provide a quantitative analysis of such phase information and show that- when combined with appropriate methods for filtering and unwrapping-it can improve the sensitivity to OS length change by more than an order of magnitude, down to 45 nm, slightly thicker than a single OS disc. We further show that phase sensitivity drops off with retinal eccentricity, and that the best location for phase imaging is close to the fovea. We apply the technique to the measurement of sub-resolution changes in the OS over matters of hours. Using custom software for registration and tracking, these microscopic changes are monitored in hundreds of cones over time. In two subjects, the OS was found to have average elongation rates of 150 nm/hr, values which agree with our previous findings.

UR - http://www.scopus.com/inward/record.url?scp=84863891099&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863891099&partnerID=8YFLogxK

U2 - 10.1364/BOE.3.000104

DO - 10.1364/BOE.3.000104

M3 - Article

VL - 3

SP - 104

EP - 124

JO - Biomedical Optics Express

JF - Biomedical Optics Express

SN - 2156-7085

IS - 1

ER -