Performance of a 97-element ALPAO membrane magnetic deformable mirror in an adaptive optics - optical coherence tomography system for in vivo imaging of the human retina

Robert Zawadzki, Steven M. Jones, Sandra E. Balderas-Mata, Sylwia M. Maliszewska, Scot S. Olivier, John S Werner

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

We present an evaluation of two different configurations of the ALPAO 97-actuator membrane magnetic deformable mirror for wavefront correction, using either 7 or 9 actuators across the eye pupil. These tests included monitoring of aberration correction for a human subject. This AO-sub system is part of the UC Davis high-resolution human retinal imaging adaptive optics - optical coherence tomography (AO-OCT) instrument. AO-OCT allows the three-dimensional (3D) visualization of different retinal structures in vivo with high volumetric resolution (3×3×3μm 3).

Original languageEnglish (US)
Pages (from-to)147-149
Number of pages3
JournalPhotonics Letters of Poland
Volume3
Issue number4
DOIs
StatePublished - 2011

Fingerprint

Magnetic mirrors
Adaptive optics
Optical tomography
Actuators
Membranes
Imaging techniques
Optical resolving power
Wavefronts
Aberrations
Visualization
Monitoring

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials

Cite this

Performance of a 97-element ALPAO membrane magnetic deformable mirror in an adaptive optics - optical coherence tomography system for in vivo imaging of the human retina. / Zawadzki, Robert; Jones, Steven M.; Balderas-Mata, Sandra E.; Maliszewska, Sylwia M.; Olivier, Scot S.; Werner, John S.

In: Photonics Letters of Poland, Vol. 3, No. 4, 2011, p. 147-149.

Research output: Contribution to journalArticle

@article{401fc43411fd43ed9e708ec7b722a121,
title = "Performance of a 97-element ALPAO membrane magnetic deformable mirror in an adaptive optics - optical coherence tomography system for in vivo imaging of the human retina",
abstract = "We present an evaluation of two different configurations of the ALPAO 97-actuator membrane magnetic deformable mirror for wavefront correction, using either 7 or 9 actuators across the eye pupil. These tests included monitoring of aberration correction for a human subject. This AO-sub system is part of the UC Davis high-resolution human retinal imaging adaptive optics - optical coherence tomography (AO-OCT) instrument. AO-OCT allows the three-dimensional (3D) visualization of different retinal structures in vivo with high volumetric resolution (3×3×3μm 3).",
author = "Robert Zawadzki and Jones, {Steven M.} and Balderas-Mata, {Sandra E.} and Maliszewska, {Sylwia M.} and Olivier, {Scot S.} and Werner, {John S}",
year = "2011",
doi = "10.4302/plp.2011.4.07",
language = "English (US)",
volume = "3",
pages = "147--149",
journal = "Photonics Letters of Poland",
issn = "2080-2242",
publisher = "Photonics Society of Poland",
number = "4",

}

TY - JOUR

T1 - Performance of a 97-element ALPAO membrane magnetic deformable mirror in an adaptive optics - optical coherence tomography system for in vivo imaging of the human retina

AU - Zawadzki, Robert

AU - Jones, Steven M.

AU - Balderas-Mata, Sandra E.

AU - Maliszewska, Sylwia M.

AU - Olivier, Scot S.

AU - Werner, John S

PY - 2011

Y1 - 2011

N2 - We present an evaluation of two different configurations of the ALPAO 97-actuator membrane magnetic deformable mirror for wavefront correction, using either 7 or 9 actuators across the eye pupil. These tests included monitoring of aberration correction for a human subject. This AO-sub system is part of the UC Davis high-resolution human retinal imaging adaptive optics - optical coherence tomography (AO-OCT) instrument. AO-OCT allows the three-dimensional (3D) visualization of different retinal structures in vivo with high volumetric resolution (3×3×3μm 3).

AB - We present an evaluation of two different configurations of the ALPAO 97-actuator membrane magnetic deformable mirror for wavefront correction, using either 7 or 9 actuators across the eye pupil. These tests included monitoring of aberration correction for a human subject. This AO-sub system is part of the UC Davis high-resolution human retinal imaging adaptive optics - optical coherence tomography (AO-OCT) instrument. AO-OCT allows the three-dimensional (3D) visualization of different retinal structures in vivo with high volumetric resolution (3×3×3μm 3).

UR - http://www.scopus.com/inward/record.url?scp=84855456469&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84855456469&partnerID=8YFLogxK

U2 - 10.4302/plp.2011.4.07

DO - 10.4302/plp.2011.4.07

M3 - Article

AN - SCOPUS:84855456469

VL - 3

SP - 147

EP - 149

JO - Photonics Letters of Poland

JF - Photonics Letters of Poland

SN - 2080-2242

IS - 4

ER -