On-line clearance: A useful tool for monitoring the effectiveness of the reuse procedure

Margaret A. Rahmati, Shahriar Rahmati, Nicholas Hoenich, Claudio Ronco, George Kaysen, Robert Levin, Nathan W. Levine

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Reprocessing of a dialyzer for repeated use in the same patient is widely practiced. The dialyzer fiber bundle volume (FBV) is monitored as an indicator of the dialyzer's suitability for continued use, with standards for reprocessed dialyzers requiring a FBV of greater than 80% of a new dialyzer to be maintained. We have used on-line measurement of clearance of sodium (OLC module, Fresenius Medical Care, Walnut Creek, CA) to assess small molecule clearance changes during and between treatments for a group of 29 chronic hemodialysis patients who reused high flux polysulfone dialyzers (F80, Fresenius Medical Care, Lexington, MA) reprocessed using citric acid and heat (95°C). Data pertaining to the initial, 5th, 10th, and 15th uses were analyzed and showed that, within a single dialysis session, there was a trend for the clearance to reduce throughout the treatment (p < 0.001). Overall, there was also a trend for clearances to decline with increasing number of reuses (p < 0.008). Changes in FBV occurred, but such changes remained within the guidelines suggested by standards. It is concluded that on-line clearance measurements provide a simple noninvasive method to monitor dialyzer performance over each use and between uses.

Original languageEnglish (US)
Pages (from-to)543-546
Number of pages4
JournalASAIO Journal
Volume49
Issue number5
DOIs
StatePublished - Sep 2003
Externally publishedYes

Fingerprint

Juglans
Health care
Fibers
Monitoring
Citric Acid
Renal Dialysis
Dialysis
Polysulfones
Hot Temperature
Sodium
Citric acid
Guidelines
Therapeutics
Fluxes
Molecules
polysulfone P 1700

ASJC Scopus subject areas

  • Biophysics
  • Bioengineering

Cite this

On-line clearance : A useful tool for monitoring the effectiveness of the reuse procedure. / Rahmati, Margaret A.; Rahmati, Shahriar; Hoenich, Nicholas; Ronco, Claudio; Kaysen, George; Levin, Robert; Levine, Nathan W.

In: ASAIO Journal, Vol. 49, No. 5, 09.2003, p. 543-546.

Research output: Contribution to journalArticle

Rahmati, MA, Rahmati, S, Hoenich, N, Ronco, C, Kaysen, G, Levin, R & Levine, NW 2003, 'On-line clearance: A useful tool for monitoring the effectiveness of the reuse procedure', ASAIO Journal, vol. 49, no. 5, pp. 543-546. https://doi.org/10.1097/01.MAT.0000084177.34517.9B
Rahmati, Margaret A. ; Rahmati, Shahriar ; Hoenich, Nicholas ; Ronco, Claudio ; Kaysen, George ; Levin, Robert ; Levine, Nathan W. / On-line clearance : A useful tool for monitoring the effectiveness of the reuse procedure. In: ASAIO Journal. 2003 ; Vol. 49, No. 5. pp. 543-546.
@article{87aa07910baf413abeeaa061378e2e7f,
title = "On-line clearance: A useful tool for monitoring the effectiveness of the reuse procedure",
abstract = "Reprocessing of a dialyzer for repeated use in the same patient is widely practiced. The dialyzer fiber bundle volume (FBV) is monitored as an indicator of the dialyzer's suitability for continued use, with standards for reprocessed dialyzers requiring a FBV of greater than 80{\%} of a new dialyzer to be maintained. We have used on-line measurement of clearance of sodium (OLC module, Fresenius Medical Care, Walnut Creek, CA) to assess small molecule clearance changes during and between treatments for a group of 29 chronic hemodialysis patients who reused high flux polysulfone dialyzers (F80, Fresenius Medical Care, Lexington, MA) reprocessed using citric acid and heat (95°C). Data pertaining to the initial, 5th, 10th, and 15th uses were analyzed and showed that, within a single dialysis session, there was a trend for the clearance to reduce throughout the treatment (p < 0.001). Overall, there was also a trend for clearances to decline with increasing number of reuses (p < 0.008). Changes in FBV occurred, but such changes remained within the guidelines suggested by standards. It is concluded that on-line clearance measurements provide a simple noninvasive method to monitor dialyzer performance over each use and between uses.",
author = "Rahmati, {Margaret A.} and Shahriar Rahmati and Nicholas Hoenich and Claudio Ronco and George Kaysen and Robert Levin and Levine, {Nathan W.}",
year = "2003",
month = "9",
doi = "10.1097/01.MAT.0000084177.34517.9B",
language = "English (US)",
volume = "49",
pages = "543--546",
journal = "ASAIO Journal",
issn = "1058-2916",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

TY - JOUR

T1 - On-line clearance

T2 - A useful tool for monitoring the effectiveness of the reuse procedure

AU - Rahmati, Margaret A.

AU - Rahmati, Shahriar

AU - Hoenich, Nicholas

AU - Ronco, Claudio

AU - Kaysen, George

AU - Levin, Robert

AU - Levine, Nathan W.

PY - 2003/9

Y1 - 2003/9

N2 - Reprocessing of a dialyzer for repeated use in the same patient is widely practiced. The dialyzer fiber bundle volume (FBV) is monitored as an indicator of the dialyzer's suitability for continued use, with standards for reprocessed dialyzers requiring a FBV of greater than 80% of a new dialyzer to be maintained. We have used on-line measurement of clearance of sodium (OLC module, Fresenius Medical Care, Walnut Creek, CA) to assess small molecule clearance changes during and between treatments for a group of 29 chronic hemodialysis patients who reused high flux polysulfone dialyzers (F80, Fresenius Medical Care, Lexington, MA) reprocessed using citric acid and heat (95°C). Data pertaining to the initial, 5th, 10th, and 15th uses were analyzed and showed that, within a single dialysis session, there was a trend for the clearance to reduce throughout the treatment (p < 0.001). Overall, there was also a trend for clearances to decline with increasing number of reuses (p < 0.008). Changes in FBV occurred, but such changes remained within the guidelines suggested by standards. It is concluded that on-line clearance measurements provide a simple noninvasive method to monitor dialyzer performance over each use and between uses.

AB - Reprocessing of a dialyzer for repeated use in the same patient is widely practiced. The dialyzer fiber bundle volume (FBV) is monitored as an indicator of the dialyzer's suitability for continued use, with standards for reprocessed dialyzers requiring a FBV of greater than 80% of a new dialyzer to be maintained. We have used on-line measurement of clearance of sodium (OLC module, Fresenius Medical Care, Walnut Creek, CA) to assess small molecule clearance changes during and between treatments for a group of 29 chronic hemodialysis patients who reused high flux polysulfone dialyzers (F80, Fresenius Medical Care, Lexington, MA) reprocessed using citric acid and heat (95°C). Data pertaining to the initial, 5th, 10th, and 15th uses were analyzed and showed that, within a single dialysis session, there was a trend for the clearance to reduce throughout the treatment (p < 0.001). Overall, there was also a trend for clearances to decline with increasing number of reuses (p < 0.008). Changes in FBV occurred, but such changes remained within the guidelines suggested by standards. It is concluded that on-line clearance measurements provide a simple noninvasive method to monitor dialyzer performance over each use and between uses.

UR - http://www.scopus.com/inward/record.url?scp=0141702106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0141702106&partnerID=8YFLogxK

U2 - 10.1097/01.MAT.0000084177.34517.9B

DO - 10.1097/01.MAT.0000084177.34517.9B

M3 - Article

C2 - 14524561

AN - SCOPUS:0141702106

VL - 49

SP - 543

EP - 546

JO - ASAIO Journal

JF - ASAIO Journal

SN - 1058-2916

IS - 5

ER -