Novel methodology to obtain salient biomechanical characteristics of insole materials

Lawrence A. Lavery, Steven A. Vela, Hisham R. Ashry, Dan R. Lanctot, Kyriacos A. Athanasiou

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Viscoelastic inserts are commonly used as artificial shock absorbers to prevent neuropathic foot ulcerations by decreasing pressure on the sole of the foot. Unfortunately, there is little scientific information available to guide physicians in the selection of appropriate insole materials. Therefore, a novel methodology was developed to form a rational platform for biomechanical characterizations of insole material durability, which consisted of in vivo gait analysis and in vitro bioengineering measurements. Results show significant differences in the compressive stiffness of the tested insoles and the rate of change over time in both compressive stiffness and peak pressures measured. Good correlations were found between pressure-time integral and Young's modulus (r2 = 0.93), and total energy applied and Young's modulus (r2 = 0.87).

Original languageEnglish (US)
Pages (from-to)266-271
Number of pages6
JournalJournal of the American Podiatric Medical Association
Volume87
Issue number6
StatePublished - 1997
Externally publishedYes

Fingerprint

Elastic Modulus
Pressure
Foot
Bioengineering
Gait
Physicians
In Vitro Techniques

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Lavery, L. A., Vela, S. A., Ashry, H. R., Lanctot, D. R., & Athanasiou, K. A. (1997). Novel methodology to obtain salient biomechanical characteristics of insole materials. Journal of the American Podiatric Medical Association, 87(6), 266-271.

Novel methodology to obtain salient biomechanical characteristics of insole materials. / Lavery, Lawrence A.; Vela, Steven A.; Ashry, Hisham R.; Lanctot, Dan R.; Athanasiou, Kyriacos A.

In: Journal of the American Podiatric Medical Association, Vol. 87, No. 6, 1997, p. 266-271.

Research output: Contribution to journalArticle

Lavery, LA, Vela, SA, Ashry, HR, Lanctot, DR & Athanasiou, KA 1997, 'Novel methodology to obtain salient biomechanical characteristics of insole materials', Journal of the American Podiatric Medical Association, vol. 87, no. 6, pp. 266-271.
Lavery, Lawrence A. ; Vela, Steven A. ; Ashry, Hisham R. ; Lanctot, Dan R. ; Athanasiou, Kyriacos A. / Novel methodology to obtain salient biomechanical characteristics of insole materials. In: Journal of the American Podiatric Medical Association. 1997 ; Vol. 87, No. 6. pp. 266-271.
@article{f75acdae26ae46efa53de2727a5a9844,
title = "Novel methodology to obtain salient biomechanical characteristics of insole materials",
abstract = "Viscoelastic inserts are commonly used as artificial shock absorbers to prevent neuropathic foot ulcerations by decreasing pressure on the sole of the foot. Unfortunately, there is little scientific information available to guide physicians in the selection of appropriate insole materials. Therefore, a novel methodology was developed to form a rational platform for biomechanical characterizations of insole material durability, which consisted of in vivo gait analysis and in vitro bioengineering measurements. Results show significant differences in the compressive stiffness of the tested insoles and the rate of change over time in both compressive stiffness and peak pressures measured. Good correlations were found between pressure-time integral and Young's modulus (r2 = 0.93), and total energy applied and Young's modulus (r2 = 0.87).",
author = "Lavery, {Lawrence A.} and Vela, {Steven A.} and Ashry, {Hisham R.} and Lanctot, {Dan R.} and Athanasiou, {Kyriacos A.}",
year = "1997",
language = "English (US)",
volume = "87",
pages = "266--271",
journal = "Journal of the American Podiatric Medical Association",
issn = "8750-7315",
publisher = "American Podiatric Medical Association",
number = "6",

}

TY - JOUR

T1 - Novel methodology to obtain salient biomechanical characteristics of insole materials

AU - Lavery, Lawrence A.

AU - Vela, Steven A.

AU - Ashry, Hisham R.

AU - Lanctot, Dan R.

AU - Athanasiou, Kyriacos A.

PY - 1997

Y1 - 1997

N2 - Viscoelastic inserts are commonly used as artificial shock absorbers to prevent neuropathic foot ulcerations by decreasing pressure on the sole of the foot. Unfortunately, there is little scientific information available to guide physicians in the selection of appropriate insole materials. Therefore, a novel methodology was developed to form a rational platform for biomechanical characterizations of insole material durability, which consisted of in vivo gait analysis and in vitro bioengineering measurements. Results show significant differences in the compressive stiffness of the tested insoles and the rate of change over time in both compressive stiffness and peak pressures measured. Good correlations were found between pressure-time integral and Young's modulus (r2 = 0.93), and total energy applied and Young's modulus (r2 = 0.87).

AB - Viscoelastic inserts are commonly used as artificial shock absorbers to prevent neuropathic foot ulcerations by decreasing pressure on the sole of the foot. Unfortunately, there is little scientific information available to guide physicians in the selection of appropriate insole materials. Therefore, a novel methodology was developed to form a rational platform for biomechanical characterizations of insole material durability, which consisted of in vivo gait analysis and in vitro bioengineering measurements. Results show significant differences in the compressive stiffness of the tested insoles and the rate of change over time in both compressive stiffness and peak pressures measured. Good correlations were found between pressure-time integral and Young's modulus (r2 = 0.93), and total energy applied and Young's modulus (r2 = 0.87).

UR - http://www.scopus.com/inward/record.url?scp=0031157665&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031157665&partnerID=8YFLogxK

M3 - Article

VL - 87

SP - 266

EP - 271

JO - Journal of the American Podiatric Medical Association

JF - Journal of the American Podiatric Medical Association

SN - 8750-7315

IS - 6

ER -