Noninvasive measurement of fetal and neonatal blood flow

Michael H Reid, R. S. Mackay, B. M T Lantz

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

A newly developed Doppler ultrasound flow measuring instrument was applied to determination of aortic arch blood flow in 6 near-term fetuses and 2 neonates and to umbilical cord flow in 2 fetuses. The method and results are presented and indicate good agreement between this noninvasive technique and expected values for aortic arch flow in human fetuses and neonates.

Original languageEnglish (US)
Pages (from-to)197-202
Number of pages6
JournalActa Radiologica - Series Diagnosis
Volume21
Issue number2 A
StatePublished - 1980

Fingerprint

fetuses
Arches
blood flow
Fetal Blood
Flow measuring instruments
Fetus
Blood
arches
Thoracic Aorta
Doppler Ultrasonography
Umbilical Cord
Ultrasonics

ASJC Scopus subject areas

  • Instrumentation

Cite this

Noninvasive measurement of fetal and neonatal blood flow. / Reid, Michael H; Mackay, R. S.; Lantz, B. M T.

In: Acta Radiologica - Series Diagnosis, Vol. 21, No. 2 A, 1980, p. 197-202.

Research output: Contribution to journalArticle

Reid, MH, Mackay, RS & Lantz, BMT 1980, 'Noninvasive measurement of fetal and neonatal blood flow', Acta Radiologica - Series Diagnosis, vol. 21, no. 2 A, pp. 197-202.
Reid, Michael H ; Mackay, R. S. ; Lantz, B. M T. / Noninvasive measurement of fetal and neonatal blood flow. In: Acta Radiologica - Series Diagnosis. 1980 ; Vol. 21, No. 2 A. pp. 197-202.
@article{8391e442aa80497c950091f75771c350,
title = "Noninvasive measurement of fetal and neonatal blood flow",
abstract = "A newly developed Doppler ultrasound flow measuring instrument was applied to determination of aortic arch blood flow in 6 near-term fetuses and 2 neonates and to umbilical cord flow in 2 fetuses. The method and results are presented and indicate good agreement between this noninvasive technique and expected values for aortic arch flow in human fetuses and neonates.",
author = "Reid, {Michael H} and Mackay, {R. S.} and Lantz, {B. M T}",
year = "1980",
language = "English (US)",
volume = "21",
pages = "197--202",
journal = "Acta Radiologica",
issn = "0284-1851",
publisher = "SAGE Publications Ltd",
number = "2 A",

}

TY - JOUR

T1 - Noninvasive measurement of fetal and neonatal blood flow

AU - Reid, Michael H

AU - Mackay, R. S.

AU - Lantz, B. M T

PY - 1980

Y1 - 1980

N2 - A newly developed Doppler ultrasound flow measuring instrument was applied to determination of aortic arch blood flow in 6 near-term fetuses and 2 neonates and to umbilical cord flow in 2 fetuses. The method and results are presented and indicate good agreement between this noninvasive technique and expected values for aortic arch flow in human fetuses and neonates.

AB - A newly developed Doppler ultrasound flow measuring instrument was applied to determination of aortic arch blood flow in 6 near-term fetuses and 2 neonates and to umbilical cord flow in 2 fetuses. The method and results are presented and indicate good agreement between this noninvasive technique and expected values for aortic arch flow in human fetuses and neonates.

UR - http://www.scopus.com/inward/record.url?scp=0018898864&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018898864&partnerID=8YFLogxK

M3 - Article

VL - 21

SP - 197

EP - 202

JO - Acta Radiologica

JF - Acta Radiologica

SN - 0284-1851

IS - 2 A

ER -