Nonefficacy of routine removal of CSF during neurodiagnostic procedures

W. E. Rothfus, Richard E Latchaw

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The charts of 750 patients were reviewed to determine the value of routinely removing cerebrospinal fluid at the time of myelography and cisternography for chemical and cytologic examination. In most patients cerebrospinal fluid findings were normal. In the few abnormal studies, the findings were often uninformative, superfluous, or insufficient for appropriate diagnosis. In no instance did routine analysis of cerebrospinal fluid uncover occult disease. Routine removal of cerebrospinal fluid for analysis in radiologic spinal taps seems to be inappropriate, and removal should be dictated by the clinical context in which the procedure is performed.

Original languageEnglish (US)
Pages (from-to)391-394
Number of pages4
JournalAmerican Journal of Roentgenology
Volume144
Issue number2
StatePublished - 1985
Externally publishedYes

Fingerprint

Cerebrospinal Fluid
Myelography
Spinal Puncture

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Nonefficacy of routine removal of CSF during neurodiagnostic procedures. / Rothfus, W. E.; Latchaw, Richard E.

In: American Journal of Roentgenology, Vol. 144, No. 2, 1985, p. 391-394.

Research output: Contribution to journalArticle

@article{ee2ac519c61e4dabb2ca9cfabdff8e75,
title = "Nonefficacy of routine removal of CSF during neurodiagnostic procedures",
abstract = "The charts of 750 patients were reviewed to determine the value of routinely removing cerebrospinal fluid at the time of myelography and cisternography for chemical and cytologic examination. In most patients cerebrospinal fluid findings were normal. In the few abnormal studies, the findings were often uninformative, superfluous, or insufficient for appropriate diagnosis. In no instance did routine analysis of cerebrospinal fluid uncover occult disease. Routine removal of cerebrospinal fluid for analysis in radiologic spinal taps seems to be inappropriate, and removal should be dictated by the clinical context in which the procedure is performed.",
author = "Rothfus, {W. E.} and Latchaw, {Richard E}",
year = "1985",
language = "English (US)",
volume = "144",
pages = "391--394",
journal = "American Journal of Roentgenology",
issn = "0361-803X",
publisher = "American Roentgen Ray Society",
number = "2",

}

TY - JOUR

T1 - Nonefficacy of routine removal of CSF during neurodiagnostic procedures

AU - Rothfus, W. E.

AU - Latchaw, Richard E

PY - 1985

Y1 - 1985

N2 - The charts of 750 patients were reviewed to determine the value of routinely removing cerebrospinal fluid at the time of myelography and cisternography for chemical and cytologic examination. In most patients cerebrospinal fluid findings were normal. In the few abnormal studies, the findings were often uninformative, superfluous, or insufficient for appropriate diagnosis. In no instance did routine analysis of cerebrospinal fluid uncover occult disease. Routine removal of cerebrospinal fluid for analysis in radiologic spinal taps seems to be inappropriate, and removal should be dictated by the clinical context in which the procedure is performed.

AB - The charts of 750 patients were reviewed to determine the value of routinely removing cerebrospinal fluid at the time of myelography and cisternography for chemical and cytologic examination. In most patients cerebrospinal fluid findings were normal. In the few abnormal studies, the findings were often uninformative, superfluous, or insufficient for appropriate diagnosis. In no instance did routine analysis of cerebrospinal fluid uncover occult disease. Routine removal of cerebrospinal fluid for analysis in radiologic spinal taps seems to be inappropriate, and removal should be dictated by the clinical context in which the procedure is performed.

UR - http://www.scopus.com/inward/record.url?scp=0021924189&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021924189&partnerID=8YFLogxK

M3 - Article

C2 - 3871288

AN - SCOPUS:0021924189

VL - 144

SP - 391

EP - 394

JO - American Journal of Roentgenology

JF - American Journal of Roentgenology

SN - 0361-803X

IS - 2

ER -