Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring

Philip Digiglio, Ruya Li, Wenqi Wang, Tingrui Pan

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Personalized mobile medicine will continue to advance through the development of wearable sensors that can wirelessly provide pertinent health information while remaining unobtrusive, comfortable, low cost, and easy to operate and interpret. It is the intention that the sensor presented hereafter can contribute to such innovation. By applying a combination of emerging microfluidic and electronic technologies, a miniature, flexible, transparent, highly sensitive and wearable pressure sensor with microfluidic elements has been implemented, referred to as a microflotronic device. High sensitivity of 0.1 kPa−1 and fast response time on the order of tens of milliseconds has been achieved on the microflotronic sensor design. Its sensitivity is among the highest in impedance-based flexible pressure sensors. Once configured into an array, the transparent device can be easily aligned over the target artery to measure blood pressure noninvasively and continuously. In addition, the ultraflexible and thin plastic construct of the microflotronic sensor (of 270 µm in height) can be worn comfortably for extended periods of time. Importantly, the proposed microflotronic sensor has been utilized to perform arterial tonometry with the capability of noninvasive monitoring of arterial blood pressure waveforms in a real-time and continuous fashion.

Original languageEnglish (US)
JournalAnnals of Biomedical Engineering
Volume42
Issue number11
DOIs
StatePublished - Jan 1 2014

Fingerprint

Hemodynamics
Monitoring
Blood pressure
Sensors
Pressure sensors
Microfluidics
Medicine
Innovation
Health
Plastics
Costs
Wearable sensors

Keywords

  • Arterial stiffness
  • Blood pressure
  • Cardiovascular disease (CVD)
  • Micro-electromechanical systems (MEMS)
  • Microfluidics
  • Mobile medicine
  • Pressure sensors
  • Pressure waveform
  • Pulse
  • Wearable sensors

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring. / Digiglio, Philip; Li, Ruya; Wang, Wenqi; Pan, Tingrui.

In: Annals of Biomedical Engineering, Vol. 42, No. 11, 01.01.2014.

Research output: Contribution to journalArticle

@article{fb793324c7364933b8b756e4f56d089a,
title = "Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring",
abstract = "Personalized mobile medicine will continue to advance through the development of wearable sensors that can wirelessly provide pertinent health information while remaining unobtrusive, comfortable, low cost, and easy to operate and interpret. It is the intention that the sensor presented hereafter can contribute to such innovation. By applying a combination of emerging microfluidic and electronic technologies, a miniature, flexible, transparent, highly sensitive and wearable pressure sensor with microfluidic elements has been implemented, referred to as a microflotronic device. High sensitivity of 0.1 kPa−1 and fast response time on the order of tens of milliseconds has been achieved on the microflotronic sensor design. Its sensitivity is among the highest in impedance-based flexible pressure sensors. Once configured into an array, the transparent device can be easily aligned over the target artery to measure blood pressure noninvasively and continuously. In addition, the ultraflexible and thin plastic construct of the microflotronic sensor (of 270 µm in height) can be worn comfortably for extended periods of time. Importantly, the proposed microflotronic sensor has been utilized to perform arterial tonometry with the capability of noninvasive monitoring of arterial blood pressure waveforms in a real-time and continuous fashion.",
keywords = "Arterial stiffness, Blood pressure, Cardiovascular disease (CVD), Micro-electromechanical systems (MEMS), Microfluidics, Mobile medicine, Pressure sensors, Pressure waveform, Pulse, Wearable sensors",
author = "Philip Digiglio and Ruya Li and Wenqi Wang and Tingrui Pan",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s10439-014-1037-1",
language = "English (US)",
volume = "42",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "11",

}

TY - JOUR

T1 - Microflotronic Arterial Tonometry for Continuous Wearable Non-Invasive Hemodynamic Monitoring

AU - Digiglio, Philip

AU - Li, Ruya

AU - Wang, Wenqi

AU - Pan, Tingrui

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Personalized mobile medicine will continue to advance through the development of wearable sensors that can wirelessly provide pertinent health information while remaining unobtrusive, comfortable, low cost, and easy to operate and interpret. It is the intention that the sensor presented hereafter can contribute to such innovation. By applying a combination of emerging microfluidic and electronic technologies, a miniature, flexible, transparent, highly sensitive and wearable pressure sensor with microfluidic elements has been implemented, referred to as a microflotronic device. High sensitivity of 0.1 kPa−1 and fast response time on the order of tens of milliseconds has been achieved on the microflotronic sensor design. Its sensitivity is among the highest in impedance-based flexible pressure sensors. Once configured into an array, the transparent device can be easily aligned over the target artery to measure blood pressure noninvasively and continuously. In addition, the ultraflexible and thin plastic construct of the microflotronic sensor (of 270 µm in height) can be worn comfortably for extended periods of time. Importantly, the proposed microflotronic sensor has been utilized to perform arterial tonometry with the capability of noninvasive monitoring of arterial blood pressure waveforms in a real-time and continuous fashion.

AB - Personalized mobile medicine will continue to advance through the development of wearable sensors that can wirelessly provide pertinent health information while remaining unobtrusive, comfortable, low cost, and easy to operate and interpret. It is the intention that the sensor presented hereafter can contribute to such innovation. By applying a combination of emerging microfluidic and electronic technologies, a miniature, flexible, transparent, highly sensitive and wearable pressure sensor with microfluidic elements has been implemented, referred to as a microflotronic device. High sensitivity of 0.1 kPa−1 and fast response time on the order of tens of milliseconds has been achieved on the microflotronic sensor design. Its sensitivity is among the highest in impedance-based flexible pressure sensors. Once configured into an array, the transparent device can be easily aligned over the target artery to measure blood pressure noninvasively and continuously. In addition, the ultraflexible and thin plastic construct of the microflotronic sensor (of 270 µm in height) can be worn comfortably for extended periods of time. Importantly, the proposed microflotronic sensor has been utilized to perform arterial tonometry with the capability of noninvasive monitoring of arterial blood pressure waveforms in a real-time and continuous fashion.

KW - Arterial stiffness

KW - Blood pressure

KW - Cardiovascular disease (CVD)

KW - Micro-electromechanical systems (MEMS)

KW - Microfluidics

KW - Mobile medicine

KW - Pressure sensors

KW - Pressure waveform

KW - Pulse

KW - Wearable sensors

UR - http://www.scopus.com/inward/record.url?scp=84919879797&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84919879797&partnerID=8YFLogxK

U2 - 10.1007/s10439-014-1037-1

DO - 10.1007/s10439-014-1037-1

M3 - Article

VL - 42

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 11

ER -