Machine perfusion following static cold storage preservation in kidney transplantation: Donor-matched pair analysis of the prognostic impact of longer pump time

Gaetano Ciancio, Jeffrey J. Gaynor, Junichiro Sageshima, David Roth, Warren Kupin, Giselle Guerra, Lissett Tueros, Alberto Zarak, Lois Hanson, Susan Ganz, Linda Chen, Phillip Ruiz, Alan S. Livingstone, George W. Burke

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

The impact of machine perfusion (MP) time on kidney transplant outcome is mixed in previous studies using multivariable analyses. In an analysis of 66 pairs of donor-matched adult, first transplant recipients (N = 132) with identical donor characteristics except for pump time, tests of association of shorter versus longer pump time (first versus second kidney removed) by delayed graft function(DGF), slow graft function(SGF), and biopsy proven acute rejection(BPAR) were performed using McNemar's test. Freedom-from-BPAR, graft and patient survival, and renal function were also compared. Mean ± SD pump times for paired recipients with first and second kidneys were 22.7 ± 7.3 h and 31.2 ± 7.9 h, respectively (mean difference: 8.5 ± 4.5 h, P <.000001). There was no significant impact of pump time on DGF or SGF, with discordant pairs favoring less SGF with longer pump time (N.S.). The incidence of BPAR during the first 12 months post-transplant yielded a borderline difference favoring longer pump time (P =.09), and freedom-from-BPAR during the first 12 months was significantly more favorable for longer pump times (95% vs. 84%, P = 0.04). No differences were observed in graft and patient survival, and renal function. While offering significantly favorable protection from BPAR, this analysis of donor-matched recipient pairs corroborates longer MP (pump) times having no unfavorable effect on other clinical outcomes.

Original languageEnglish (US)
Pages (from-to)34-40
Number of pages7
JournalTransplant International
Volume25
Issue number1
DOIs
StatePublished - Jan 1 2012
Externally publishedYes

Fingerprint

Matched-Pair Analysis
Kidney Transplantation
Perfusion
Tissue Donors
Transplants
Kidney
Biopsy
Delayed Graft Function
Graft Survival
Infusion Pumps

Keywords

  • biopsy-proven acute rejection
  • delayed graft function
  • duration of machine perfusion (pump) time
  • kidney transplantation
  • machine perfusion
  • static cold storage

ASJC Scopus subject areas

  • Transplantation

Cite this

Machine perfusion following static cold storage preservation in kidney transplantation : Donor-matched pair analysis of the prognostic impact of longer pump time. / Ciancio, Gaetano; Gaynor, Jeffrey J.; Sageshima, Junichiro; Roth, David; Kupin, Warren; Guerra, Giselle; Tueros, Lissett; Zarak, Alberto; Hanson, Lois; Ganz, Susan; Chen, Linda; Ruiz, Phillip; Livingstone, Alan S.; Burke, George W.

In: Transplant International, Vol. 25, No. 1, 01.01.2012, p. 34-40.

Research output: Contribution to journalArticle

Ciancio, G, Gaynor, JJ, Sageshima, J, Roth, D, Kupin, W, Guerra, G, Tueros, L, Zarak, A, Hanson, L, Ganz, S, Chen, L, Ruiz, P, Livingstone, AS & Burke, GW 2012, 'Machine perfusion following static cold storage preservation in kidney transplantation: Donor-matched pair analysis of the prognostic impact of longer pump time', Transplant International, vol. 25, no. 1, pp. 34-40. https://doi.org/10.1111/j.1432-2277.2011.01364.x
Ciancio, Gaetano ; Gaynor, Jeffrey J. ; Sageshima, Junichiro ; Roth, David ; Kupin, Warren ; Guerra, Giselle ; Tueros, Lissett ; Zarak, Alberto ; Hanson, Lois ; Ganz, Susan ; Chen, Linda ; Ruiz, Phillip ; Livingstone, Alan S. ; Burke, George W. / Machine perfusion following static cold storage preservation in kidney transplantation : Donor-matched pair analysis of the prognostic impact of longer pump time. In: Transplant International. 2012 ; Vol. 25, No. 1. pp. 34-40.
@article{8046b578dbee425288a3471e0b6980e5,
title = "Machine perfusion following static cold storage preservation in kidney transplantation: Donor-matched pair analysis of the prognostic impact of longer pump time",
abstract = "The impact of machine perfusion (MP) time on kidney transplant outcome is mixed in previous studies using multivariable analyses. In an analysis of 66 pairs of donor-matched adult, first transplant recipients (N = 132) with identical donor characteristics except for pump time, tests of association of shorter versus longer pump time (first versus second kidney removed) by delayed graft function(DGF), slow graft function(SGF), and biopsy proven acute rejection(BPAR) were performed using McNemar's test. Freedom-from-BPAR, graft and patient survival, and renal function were also compared. Mean ± SD pump times for paired recipients with first and second kidneys were 22.7 ± 7.3 h and 31.2 ± 7.9 h, respectively (mean difference: 8.5 ± 4.5 h, P <.000001). There was no significant impact of pump time on DGF or SGF, with discordant pairs favoring less SGF with longer pump time (N.S.). The incidence of BPAR during the first 12 months post-transplant yielded a borderline difference favoring longer pump time (P =.09), and freedom-from-BPAR during the first 12 months was significantly more favorable for longer pump times (95{\%} vs. 84{\%}, P = 0.04). No differences were observed in graft and patient survival, and renal function. While offering significantly favorable protection from BPAR, this analysis of donor-matched recipient pairs corroborates longer MP (pump) times having no unfavorable effect on other clinical outcomes.",
keywords = "biopsy-proven acute rejection, delayed graft function, duration of machine perfusion (pump) time, kidney transplantation, machine perfusion, static cold storage",
author = "Gaetano Ciancio and Gaynor, {Jeffrey J.} and Junichiro Sageshima and David Roth and Warren Kupin and Giselle Guerra and Lissett Tueros and Alberto Zarak and Lois Hanson and Susan Ganz and Linda Chen and Phillip Ruiz and Livingstone, {Alan S.} and Burke, {George W.}",
year = "2012",
month = "1",
day = "1",
doi = "10.1111/j.1432-2277.2011.01364.x",
language = "English (US)",
volume = "25",
pages = "34--40",
journal = "Transplant International",
issn = "0934-0874",
publisher = "Wiley-Blackwell",
number = "1",

}

TY - JOUR

T1 - Machine perfusion following static cold storage preservation in kidney transplantation

T2 - Donor-matched pair analysis of the prognostic impact of longer pump time

AU - Ciancio, Gaetano

AU - Gaynor, Jeffrey J.

AU - Sageshima, Junichiro

AU - Roth, David

AU - Kupin, Warren

AU - Guerra, Giselle

AU - Tueros, Lissett

AU - Zarak, Alberto

AU - Hanson, Lois

AU - Ganz, Susan

AU - Chen, Linda

AU - Ruiz, Phillip

AU - Livingstone, Alan S.

AU - Burke, George W.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - The impact of machine perfusion (MP) time on kidney transplant outcome is mixed in previous studies using multivariable analyses. In an analysis of 66 pairs of donor-matched adult, first transplant recipients (N = 132) with identical donor characteristics except for pump time, tests of association of shorter versus longer pump time (first versus second kidney removed) by delayed graft function(DGF), slow graft function(SGF), and biopsy proven acute rejection(BPAR) were performed using McNemar's test. Freedom-from-BPAR, graft and patient survival, and renal function were also compared. Mean ± SD pump times for paired recipients with first and second kidneys were 22.7 ± 7.3 h and 31.2 ± 7.9 h, respectively (mean difference: 8.5 ± 4.5 h, P <.000001). There was no significant impact of pump time on DGF or SGF, with discordant pairs favoring less SGF with longer pump time (N.S.). The incidence of BPAR during the first 12 months post-transplant yielded a borderline difference favoring longer pump time (P =.09), and freedom-from-BPAR during the first 12 months was significantly more favorable for longer pump times (95% vs. 84%, P = 0.04). No differences were observed in graft and patient survival, and renal function. While offering significantly favorable protection from BPAR, this analysis of donor-matched recipient pairs corroborates longer MP (pump) times having no unfavorable effect on other clinical outcomes.

AB - The impact of machine perfusion (MP) time on kidney transplant outcome is mixed in previous studies using multivariable analyses. In an analysis of 66 pairs of donor-matched adult, first transplant recipients (N = 132) with identical donor characteristics except for pump time, tests of association of shorter versus longer pump time (first versus second kidney removed) by delayed graft function(DGF), slow graft function(SGF), and biopsy proven acute rejection(BPAR) were performed using McNemar's test. Freedom-from-BPAR, graft and patient survival, and renal function were also compared. Mean ± SD pump times for paired recipients with first and second kidneys were 22.7 ± 7.3 h and 31.2 ± 7.9 h, respectively (mean difference: 8.5 ± 4.5 h, P <.000001). There was no significant impact of pump time on DGF or SGF, with discordant pairs favoring less SGF with longer pump time (N.S.). The incidence of BPAR during the first 12 months post-transplant yielded a borderline difference favoring longer pump time (P =.09), and freedom-from-BPAR during the first 12 months was significantly more favorable for longer pump times (95% vs. 84%, P = 0.04). No differences were observed in graft and patient survival, and renal function. While offering significantly favorable protection from BPAR, this analysis of donor-matched recipient pairs corroborates longer MP (pump) times having no unfavorable effect on other clinical outcomes.

KW - biopsy-proven acute rejection

KW - delayed graft function

KW - duration of machine perfusion (pump) time

KW - kidney transplantation

KW - machine perfusion

KW - static cold storage

UR - http://www.scopus.com/inward/record.url?scp=83955161708&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=83955161708&partnerID=8YFLogxK

U2 - 10.1111/j.1432-2277.2011.01364.x

DO - 10.1111/j.1432-2277.2011.01364.x

M3 - Article

C2 - 21981661

AN - SCOPUS:83955161708

VL - 25

SP - 34

EP - 40

JO - Transplant International

JF - Transplant International

SN - 0934-0874

IS - 1

ER -