In vivo microelectrode localization in the brain of the alert monkey: a combined radiographic and magnetic resonance imaging approach

Frederick K D Nahm, Anders M. Dale, Thomas D. Albright, David G Amaral

Research output: Contribution to journalArticle

21 Citations (Scopus)

Abstract

A technique is described for in vivo localization of microelectrodes during single-unit recording in the alert monkey. Four hollow glass spheres filled with copper sulfate and iohexol were affixed to the surface of the animal's skull prior to the acquisition of a series of coronal magnetic resonance (MR) images. These reference beads were visible in both X-ray and MR images. Cranial recording chambers were then implanted bilaterally over the amygdaloid complex. A microelectrode was advanced to various depths in the subject's brain. At each selected microelectrode site, five radiographs were obtained and a small electrolytic lesion was made. Based on the data from the radiographs, we computed the position of the microelectrode tip at each site relative to the reference beads. With a precision of 625 μm, this method was used to predict the neuroanatomical location of ten microlesions placed in both subcortical and cortical structures. Postmortem histological analysis revealed that the actual location of the lesions closely matched predictions arrived at using the X-ray/MRI localization technique. This technique thus provides an accurate, reliable and noninvasive method for in vivo localization of microelectrode recording sites.

Original languageEnglish (US)
Pages (from-to)401-411
Number of pages11
JournalExperimental Brain Research
Volume98
Issue number3
DOIs
StatePublished - Apr 1994
Externally publishedYes

Fingerprint

Microelectrodes
Haplorhini
Magnetic Resonance Imaging
Brain
Magnetic Resonance Spectroscopy
X-Rays
Iohexol
Copper Sulfate
Skull
Glass

Keywords

  • Magnetic resonance imaging
  • Microlesion
  • Monkey
  • Radiography
  • Single-Unit

ASJC Scopus subject areas

  • Neuroscience(all)

Cite this

In vivo microelectrode localization in the brain of the alert monkey : a combined radiographic and magnetic resonance imaging approach. / Nahm, Frederick K D; Dale, Anders M.; Albright, Thomas D.; Amaral, David G.

In: Experimental Brain Research, Vol. 98, No. 3, 04.1994, p. 401-411.

Research output: Contribution to journalArticle

@article{dd9de540f2b749628ef6c8bda56d868b,
title = "In vivo microelectrode localization in the brain of the alert monkey: a combined radiographic and magnetic resonance imaging approach",
abstract = "A technique is described for in vivo localization of microelectrodes during single-unit recording in the alert monkey. Four hollow glass spheres filled with copper sulfate and iohexol were affixed to the surface of the animal's skull prior to the acquisition of a series of coronal magnetic resonance (MR) images. These reference beads were visible in both X-ray and MR images. Cranial recording chambers were then implanted bilaterally over the amygdaloid complex. A microelectrode was advanced to various depths in the subject's brain. At each selected microelectrode site, five radiographs were obtained and a small electrolytic lesion was made. Based on the data from the radiographs, we computed the position of the microelectrode tip at each site relative to the reference beads. With a precision of 625 μm, this method was used to predict the neuroanatomical location of ten microlesions placed in both subcortical and cortical structures. Postmortem histological analysis revealed that the actual location of the lesions closely matched predictions arrived at using the X-ray/MRI localization technique. This technique thus provides an accurate, reliable and noninvasive method for in vivo localization of microelectrode recording sites.",
keywords = "Magnetic resonance imaging, Microlesion, Monkey, Radiography, Single-Unit",
author = "Nahm, {Frederick K D} and Dale, {Anders M.} and Albright, {Thomas D.} and Amaral, {David G}",
year = "1994",
month = "4",
doi = "10.1007/BF00233978",
language = "English (US)",
volume = "98",
pages = "401--411",
journal = "Experimental Brain Research",
issn = "0014-4819",
publisher = "Springer Verlag",
number = "3",

}

TY - JOUR

T1 - In vivo microelectrode localization in the brain of the alert monkey

T2 - a combined radiographic and magnetic resonance imaging approach

AU - Nahm, Frederick K D

AU - Dale, Anders M.

AU - Albright, Thomas D.

AU - Amaral, David G

PY - 1994/4

Y1 - 1994/4

N2 - A technique is described for in vivo localization of microelectrodes during single-unit recording in the alert monkey. Four hollow glass spheres filled with copper sulfate and iohexol were affixed to the surface of the animal's skull prior to the acquisition of a series of coronal magnetic resonance (MR) images. These reference beads were visible in both X-ray and MR images. Cranial recording chambers were then implanted bilaterally over the amygdaloid complex. A microelectrode was advanced to various depths in the subject's brain. At each selected microelectrode site, five radiographs were obtained and a small electrolytic lesion was made. Based on the data from the radiographs, we computed the position of the microelectrode tip at each site relative to the reference beads. With a precision of 625 μm, this method was used to predict the neuroanatomical location of ten microlesions placed in both subcortical and cortical structures. Postmortem histological analysis revealed that the actual location of the lesions closely matched predictions arrived at using the X-ray/MRI localization technique. This technique thus provides an accurate, reliable and noninvasive method for in vivo localization of microelectrode recording sites.

AB - A technique is described for in vivo localization of microelectrodes during single-unit recording in the alert monkey. Four hollow glass spheres filled with copper sulfate and iohexol were affixed to the surface of the animal's skull prior to the acquisition of a series of coronal magnetic resonance (MR) images. These reference beads were visible in both X-ray and MR images. Cranial recording chambers were then implanted bilaterally over the amygdaloid complex. A microelectrode was advanced to various depths in the subject's brain. At each selected microelectrode site, five radiographs were obtained and a small electrolytic lesion was made. Based on the data from the radiographs, we computed the position of the microelectrode tip at each site relative to the reference beads. With a precision of 625 μm, this method was used to predict the neuroanatomical location of ten microlesions placed in both subcortical and cortical structures. Postmortem histological analysis revealed that the actual location of the lesions closely matched predictions arrived at using the X-ray/MRI localization technique. This technique thus provides an accurate, reliable and noninvasive method for in vivo localization of microelectrode recording sites.

KW - Magnetic resonance imaging

KW - Microlesion

KW - Monkey

KW - Radiography

KW - Single-Unit

UR - http://www.scopus.com/inward/record.url?scp=0028362599&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028362599&partnerID=8YFLogxK

U2 - 10.1007/BF00233978

DO - 10.1007/BF00233978

M3 - Article

C2 - 8056063

AN - SCOPUS:0028362599

VL - 98

SP - 401

EP - 411

JO - Experimental Brain Research

JF - Experimental Brain Research

SN - 0014-4819

IS - 3

ER -