Improved Detection of Focal Cerebral Blood Flow Changes Using Three-Dimensional Positron Emission Tomography

Simon R Cherry, Roger P. Woods, Edward J. Hoffman, John C. Mazziotta

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

Removal of the interplane septa and configuration of a typical multislice PET scanner to accept all possible coincidence lines of response leads to a fivefold increase in sensitivity. This can be of value in regional CBF studies using bolus 15/O-labeled water injections, allowing the injected dose to be reduced by a factor of 4, while maintaining the same number of noise equivalent counts. Thus, for a given cumulative dose limit, four times as many studies can be performed in a single subject. Data from the three-dimensional Huffman brain phantom, closely matched to count rates seen in human studies, show that for an identical cumulative dose, the noise in subtraction (stimulus minus baseline) images can be reduced by a factor of 2 using three-dimensional data acquisition, with appropriate fractionation of the dose. This improvement is dependent on axial position due to the sensitivity characteristics of three-dimensional scans; however, there is a significant gain in the signal-to-noise ratio (S/N) in all image planes. Studies performed in a human subject demonstrate how the factor of 2 gain in S/N leads to improved detectability of activation sites in PET subtraction images.

Original languageEnglish (US)
Pages (from-to)630-638
Number of pages9
JournalJournal of Cerebral Blood Flow and Metabolism
Volume13
Issue number4
StatePublished - 1993

Fingerprint

Cerebrovascular Circulation
Positron-Emission Tomography
Noise
Dose Fractionation
Signal-To-Noise Ratio
Injections
Water
Brain

Keywords

  • Activation
  • Cerebral blood flow
  • Dimensional imaging.s
  • Positron emission tomography
  • Three

ASJC Scopus subject areas

  • Endocrinology
  • Endocrinology, Diabetes and Metabolism
  • Neuroscience(all)

Cite this

Improved Detection of Focal Cerebral Blood Flow Changes Using Three-Dimensional Positron Emission Tomography. / Cherry, Simon R; Woods, Roger P.; Hoffman, Edward J.; Mazziotta, John C.

In: Journal of Cerebral Blood Flow and Metabolism, Vol. 13, No. 4, 1993, p. 630-638.

Research output: Contribution to journalArticle

@article{2a22caf30ee141b6a33f4a52008cdccd,
title = "Improved Detection of Focal Cerebral Blood Flow Changes Using Three-Dimensional Positron Emission Tomography",
abstract = "Removal of the interplane septa and configuration of a typical multislice PET scanner to accept all possible coincidence lines of response leads to a fivefold increase in sensitivity. This can be of value in regional CBF studies using bolus 15/O-labeled water injections, allowing the injected dose to be reduced by a factor of 4, while maintaining the same number of noise equivalent counts. Thus, for a given cumulative dose limit, four times as many studies can be performed in a single subject. Data from the three-dimensional Huffman brain phantom, closely matched to count rates seen in human studies, show that for an identical cumulative dose, the noise in subtraction (stimulus minus baseline) images can be reduced by a factor of 2 using three-dimensional data acquisition, with appropriate fractionation of the dose. This improvement is dependent on axial position due to the sensitivity characteristics of three-dimensional scans; however, there is a significant gain in the signal-to-noise ratio (S/N) in all image planes. Studies performed in a human subject demonstrate how the factor of 2 gain in S/N leads to improved detectability of activation sites in PET subtraction images.",
keywords = "Activation, Cerebral blood flow, Dimensional imaging.s, Positron emission tomography, Three",
author = "Cherry, {Simon R} and Woods, {Roger P.} and Hoffman, {Edward J.} and Mazziotta, {John C.}",
year = "1993",
language = "English (US)",
volume = "13",
pages = "630--638",
journal = "Journal of Cerebral Blood Flow and Metabolism",
issn = "0271-678X",
publisher = "Nature Publishing Group",
number = "4",

}

TY - JOUR

T1 - Improved Detection of Focal Cerebral Blood Flow Changes Using Three-Dimensional Positron Emission Tomography

AU - Cherry, Simon R

AU - Woods, Roger P.

AU - Hoffman, Edward J.

AU - Mazziotta, John C.

PY - 1993

Y1 - 1993

N2 - Removal of the interplane septa and configuration of a typical multislice PET scanner to accept all possible coincidence lines of response leads to a fivefold increase in sensitivity. This can be of value in regional CBF studies using bolus 15/O-labeled water injections, allowing the injected dose to be reduced by a factor of 4, while maintaining the same number of noise equivalent counts. Thus, for a given cumulative dose limit, four times as many studies can be performed in a single subject. Data from the three-dimensional Huffman brain phantom, closely matched to count rates seen in human studies, show that for an identical cumulative dose, the noise in subtraction (stimulus minus baseline) images can be reduced by a factor of 2 using three-dimensional data acquisition, with appropriate fractionation of the dose. This improvement is dependent on axial position due to the sensitivity characteristics of three-dimensional scans; however, there is a significant gain in the signal-to-noise ratio (S/N) in all image planes. Studies performed in a human subject demonstrate how the factor of 2 gain in S/N leads to improved detectability of activation sites in PET subtraction images.

AB - Removal of the interplane septa and configuration of a typical multislice PET scanner to accept all possible coincidence lines of response leads to a fivefold increase in sensitivity. This can be of value in regional CBF studies using bolus 15/O-labeled water injections, allowing the injected dose to be reduced by a factor of 4, while maintaining the same number of noise equivalent counts. Thus, for a given cumulative dose limit, four times as many studies can be performed in a single subject. Data from the three-dimensional Huffman brain phantom, closely matched to count rates seen in human studies, show that for an identical cumulative dose, the noise in subtraction (stimulus minus baseline) images can be reduced by a factor of 2 using three-dimensional data acquisition, with appropriate fractionation of the dose. This improvement is dependent on axial position due to the sensitivity characteristics of three-dimensional scans; however, there is a significant gain in the signal-to-noise ratio (S/N) in all image planes. Studies performed in a human subject demonstrate how the factor of 2 gain in S/N leads to improved detectability of activation sites in PET subtraction images.

KW - Activation

KW - Cerebral blood flow

KW - Dimensional imaging.s

KW - Positron emission tomography

KW - Three

UR - http://www.scopus.com/inward/record.url?scp=0027196257&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027196257&partnerID=8YFLogxK

M3 - Article

C2 - 8314916

AN - SCOPUS:0027196257

VL - 13

SP - 630

EP - 638

JO - Journal of Cerebral Blood Flow and Metabolism

JF - Journal of Cerebral Blood Flow and Metabolism

SN - 0271-678X

IS - 4

ER -