Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics

Omer P. Kocaoglu, Sangyeol Lee, Ravi Jonnal, Qiang Wang, Ashley E. Herde, Jack C. Derby, Weihua Gao, Donald T. Miller

Research output: Contribution to journalArticle

73 Citations (Scopus)

Abstract

Cone photoreceptors in the living human eye have recently been imaged with micron-scale resolution in all three spatial dimensions using adaptive optics optical coherence tomography. While these advances have allowed non-invasive study of the three-dimensional structure of living human cones, studies of their function and physiology are still hampered by the difficulties to monitor the same cells over time. The purpose of this study is to demonstrate the feasibility of cone monitoring using ultrahigh-resolution adaptive optics optical coherence tomography. Critical to this is incorporation of a high speed CMOS camera (125 KHz) and a novel feature-based, image registration/dewarping algorithm for reducing the deleterious effects of eye motion on volume images. Volume movies were acquired on three healthy subjects at retinal eccentricities from 0.5° to 6°. Image registration/dewarping reduced motion artifacts in the movies from 15 μm to 1.3 μm root mean square, the latter sufficient for identifying and tracking cones. Cone row-to-row spacing and outer segment lengths were consistent with that reported in the literature. Cone length analysis demonstrates that UHR-AO-OCT is sufficiently sensitive to measure real length differences between cones in the same 0.5° retinal patch and requires no more than five measurements of OS length to achieve 95% confidence. We know of no other imaging modality that can monitor foveal or parafoveal cones over time with comparable resolution in all three dimensions.

Original languageEnglish (US)
Pages (from-to)748-763
Number of pages16
JournalBiomedical Optics Express
Volume2
Issue number4
DOIs
StatePublished - Apr 1 2011
Externally publishedYes

Fingerprint

Retinal Cone Photoreceptor Cells
photoreceptors
Optical Coherence Tomography
Motion Pictures
adaptive optics
cones
tomography
Artifacts
Healthy Volunteers
physiology
eccentricity
artifacts
confidence
CMOS
cameras
spacing
high speed

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Biotechnology

Cite this

Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics. / Kocaoglu, Omer P.; Lee, Sangyeol; Jonnal, Ravi; Wang, Qiang; Herde, Ashley E.; Derby, Jack C.; Gao, Weihua; Miller, Donald T.

In: Biomedical Optics Express, Vol. 2, No. 4, 01.04.2011, p. 748-763.

Research output: Contribution to journalArticle

Kocaoglu, Omer P. ; Lee, Sangyeol ; Jonnal, Ravi ; Wang, Qiang ; Herde, Ashley E. ; Derby, Jack C. ; Gao, Weihua ; Miller, Donald T. / Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics. In: Biomedical Optics Express. 2011 ; Vol. 2, No. 4. pp. 748-763.
@article{a9bd0b495d4b468d881ec879d7ac0cfa,
title = "Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics",
abstract = "Cone photoreceptors in the living human eye have recently been imaged with micron-scale resolution in all three spatial dimensions using adaptive optics optical coherence tomography. While these advances have allowed non-invasive study of the three-dimensional structure of living human cones, studies of their function and physiology are still hampered by the difficulties to monitor the same cells over time. The purpose of this study is to demonstrate the feasibility of cone monitoring using ultrahigh-resolution adaptive optics optical coherence tomography. Critical to this is incorporation of a high speed CMOS camera (125 KHz) and a novel feature-based, image registration/dewarping algorithm for reducing the deleterious effects of eye motion on volume images. Volume movies were acquired on three healthy subjects at retinal eccentricities from 0.5° to 6°. Image registration/dewarping reduced motion artifacts in the movies from 15 μm to 1.3 μm root mean square, the latter sufficient for identifying and tracking cones. Cone row-to-row spacing and outer segment lengths were consistent with that reported in the literature. Cone length analysis demonstrates that UHR-AO-OCT is sufficiently sensitive to measure real length differences between cones in the same 0.5° retinal patch and requires no more than five measurements of OS length to achieve 95{\%} confidence. We know of no other imaging modality that can monitor foveal or parafoveal cones over time with comparable resolution in all three dimensions.",
author = "Kocaoglu, {Omer P.} and Sangyeol Lee and Ravi Jonnal and Qiang Wang and Herde, {Ashley E.} and Derby, {Jack C.} and Weihua Gao and Miller, {Donald T.}",
year = "2011",
month = "4",
day = "1",
doi = "10.1364/BOE.2.000748",
language = "English (US)",
volume = "2",
pages = "748--763",
journal = "Biomedical Optics Express",
issn = "2156-7085",
publisher = "The Optical Society",
number = "4",

}

TY - JOUR

T1 - Imaging cone photoreceptors in three dimensions and in time using ultrahigh resolution optical coherence tomography with adaptive optics

AU - Kocaoglu, Omer P.

AU - Lee, Sangyeol

AU - Jonnal, Ravi

AU - Wang, Qiang

AU - Herde, Ashley E.

AU - Derby, Jack C.

AU - Gao, Weihua

AU - Miller, Donald T.

PY - 2011/4/1

Y1 - 2011/4/1

N2 - Cone photoreceptors in the living human eye have recently been imaged with micron-scale resolution in all three spatial dimensions using adaptive optics optical coherence tomography. While these advances have allowed non-invasive study of the three-dimensional structure of living human cones, studies of their function and physiology are still hampered by the difficulties to monitor the same cells over time. The purpose of this study is to demonstrate the feasibility of cone monitoring using ultrahigh-resolution adaptive optics optical coherence tomography. Critical to this is incorporation of a high speed CMOS camera (125 KHz) and a novel feature-based, image registration/dewarping algorithm for reducing the deleterious effects of eye motion on volume images. Volume movies were acquired on three healthy subjects at retinal eccentricities from 0.5° to 6°. Image registration/dewarping reduced motion artifacts in the movies from 15 μm to 1.3 μm root mean square, the latter sufficient for identifying and tracking cones. Cone row-to-row spacing and outer segment lengths were consistent with that reported in the literature. Cone length analysis demonstrates that UHR-AO-OCT is sufficiently sensitive to measure real length differences between cones in the same 0.5° retinal patch and requires no more than five measurements of OS length to achieve 95% confidence. We know of no other imaging modality that can monitor foveal or parafoveal cones over time with comparable resolution in all three dimensions.

AB - Cone photoreceptors in the living human eye have recently been imaged with micron-scale resolution in all three spatial dimensions using adaptive optics optical coherence tomography. While these advances have allowed non-invasive study of the three-dimensional structure of living human cones, studies of their function and physiology are still hampered by the difficulties to monitor the same cells over time. The purpose of this study is to demonstrate the feasibility of cone monitoring using ultrahigh-resolution adaptive optics optical coherence tomography. Critical to this is incorporation of a high speed CMOS camera (125 KHz) and a novel feature-based, image registration/dewarping algorithm for reducing the deleterious effects of eye motion on volume images. Volume movies were acquired on three healthy subjects at retinal eccentricities from 0.5° to 6°. Image registration/dewarping reduced motion artifacts in the movies from 15 μm to 1.3 μm root mean square, the latter sufficient for identifying and tracking cones. Cone row-to-row spacing and outer segment lengths were consistent with that reported in the literature. Cone length analysis demonstrates that UHR-AO-OCT is sufficiently sensitive to measure real length differences between cones in the same 0.5° retinal patch and requires no more than five measurements of OS length to achieve 95% confidence. We know of no other imaging modality that can monitor foveal or parafoveal cones over time with comparable resolution in all three dimensions.

UR - http://www.scopus.com/inward/record.url?scp=79960644784&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960644784&partnerID=8YFLogxK

U2 - 10.1364/BOE.2.000748

DO - 10.1364/BOE.2.000748

M3 - Article

C2 - 21483600

AN - SCOPUS:79960644784

VL - 2

SP - 748

EP - 763

JO - Biomedical Optics Express

JF - Biomedical Optics Express

SN - 2156-7085

IS - 4

ER -