Idiopathic Localized Eosinophilic Synovitis in a Cat

Deborah C. Silverstein, Frederick S. Almy, Joseph G. Zinkl, Mary M. Christopher

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

Background-Delayed analysis of blood samples may be caused by restricted access to laboratories. Artifactual changes may occur in the measured analytes as a consequence of delayed analysis and may complicate interpretation of the data. Objective-The purpose of this study was to characterize artifactual changes in equine blood, due to storage, using the Advia 120 hematology analyzer. Methods-Samples of blood from 5 horses were analyzed using the Advia 120 soon after collection and again after 24 and 48 hours of storage at either 4°C or ambient laboratory temperature (∼24°C). Results-Delayed analysis of equine blood samples resulted in increased numbers of normocytic hypochromic RBCs, increased numbers of macrocytic hypochromic RBCs, misclassification of granulocytes as mononuclear cells using the basophil reagent method, and pseudothrombocytosis, due to misclassification of ghost RBCS as platelets. The latter artifact was corrected by an amended version of the software. Many of the artifactual changes were identified by morphology flags. Conclusion-Characteristic changes in cytograms produced by the Advia 120 allowed recognition of artifactual changes in stored equine blood samples. These changes were less pronounced in samples stored at 24°C than at 4°C.

Original languageEnglish (US)
Pages (from-to)90-94
Number of pages5
JournalVeterinary Clinical Pathology
Volume31
Issue number2
DOIs
StatePublished - Jan 1 2002

Fingerprint

synovitis
Cats
Horses
cats
horses
blood
sampling
basophils
hematologic tests
Basophils
erythrocyte count
Hematology
granulocytes
hematology
Granulocytes
Artifacts
erythrocytes
Blood Platelets
Software
Eosinophilic synovitis

Keywords

  • Advia 120
  • Artifact
  • Ghost erythrocyte
  • Horse
  • Pseudothrombocytosis

ASJC Scopus subject areas

  • veterinary(all)

Cite this

Idiopathic Localized Eosinophilic Synovitis in a Cat. / Silverstein, Deborah C.; Almy, Frederick S.; Zinkl, Joseph G.; Christopher, Mary M.

In: Veterinary Clinical Pathology, Vol. 31, No. 2, 01.01.2002, p. 90-94.

Research output: Contribution to journalArticle

Silverstein, Deborah C. ; Almy, Frederick S. ; Zinkl, Joseph G. ; Christopher, Mary M. / Idiopathic Localized Eosinophilic Synovitis in a Cat. In: Veterinary Clinical Pathology. 2002 ; Vol. 31, No. 2. pp. 90-94.
@article{a2406a1c927d4a23ad04138e48a8562e,
title = "Idiopathic Localized Eosinophilic Synovitis in a Cat",
abstract = "Background-Delayed analysis of blood samples may be caused by restricted access to laboratories. Artifactual changes may occur in the measured analytes as a consequence of delayed analysis and may complicate interpretation of the data. Objective-The purpose of this study was to characterize artifactual changes in equine blood, due to storage, using the Advia 120 hematology analyzer. Methods-Samples of blood from 5 horses were analyzed using the Advia 120 soon after collection and again after 24 and 48 hours of storage at either 4°C or ambient laboratory temperature (∼24°C). Results-Delayed analysis of equine blood samples resulted in increased numbers of normocytic hypochromic RBCs, increased numbers of macrocytic hypochromic RBCs, misclassification of granulocytes as mononuclear cells using the basophil reagent method, and pseudothrombocytosis, due to misclassification of ghost RBCS as platelets. The latter artifact was corrected by an amended version of the software. Many of the artifactual changes were identified by morphology flags. Conclusion-Characteristic changes in cytograms produced by the Advia 120 allowed recognition of artifactual changes in stored equine blood samples. These changes were less pronounced in samples stored at 24°C than at 4°C.",
keywords = "Advia 120, Artifact, Ghost erythrocyte, Horse, Pseudothrombocytosis",
author = "Silverstein, {Deborah C.} and Almy, {Frederick S.} and Zinkl, {Joseph G.} and Christopher, {Mary M.}",
year = "2002",
month = "1",
day = "1",
doi = "10.1111/j.1939-165X.2002.tb00286.x",
language = "English (US)",
volume = "31",
pages = "90--94",
journal = "Veterinary Clinical Pathology",
issn = "0275-6382",
publisher = "American Society for Veterinary Clinical Pathology",
number = "2",

}

TY - JOUR

T1 - Idiopathic Localized Eosinophilic Synovitis in a Cat

AU - Silverstein, Deborah C.

AU - Almy, Frederick S.

AU - Zinkl, Joseph G.

AU - Christopher, Mary M.

PY - 2002/1/1

Y1 - 2002/1/1

N2 - Background-Delayed analysis of blood samples may be caused by restricted access to laboratories. Artifactual changes may occur in the measured analytes as a consequence of delayed analysis and may complicate interpretation of the data. Objective-The purpose of this study was to characterize artifactual changes in equine blood, due to storage, using the Advia 120 hematology analyzer. Methods-Samples of blood from 5 horses were analyzed using the Advia 120 soon after collection and again after 24 and 48 hours of storage at either 4°C or ambient laboratory temperature (∼24°C). Results-Delayed analysis of equine blood samples resulted in increased numbers of normocytic hypochromic RBCs, increased numbers of macrocytic hypochromic RBCs, misclassification of granulocytes as mononuclear cells using the basophil reagent method, and pseudothrombocytosis, due to misclassification of ghost RBCS as platelets. The latter artifact was corrected by an amended version of the software. Many of the artifactual changes were identified by morphology flags. Conclusion-Characteristic changes in cytograms produced by the Advia 120 allowed recognition of artifactual changes in stored equine blood samples. These changes were less pronounced in samples stored at 24°C than at 4°C.

AB - Background-Delayed analysis of blood samples may be caused by restricted access to laboratories. Artifactual changes may occur in the measured analytes as a consequence of delayed analysis and may complicate interpretation of the data. Objective-The purpose of this study was to characterize artifactual changes in equine blood, due to storage, using the Advia 120 hematology analyzer. Methods-Samples of blood from 5 horses were analyzed using the Advia 120 soon after collection and again after 24 and 48 hours of storage at either 4°C or ambient laboratory temperature (∼24°C). Results-Delayed analysis of equine blood samples resulted in increased numbers of normocytic hypochromic RBCs, increased numbers of macrocytic hypochromic RBCs, misclassification of granulocytes as mononuclear cells using the basophil reagent method, and pseudothrombocytosis, due to misclassification of ghost RBCS as platelets. The latter artifact was corrected by an amended version of the software. Many of the artifactual changes were identified by morphology flags. Conclusion-Characteristic changes in cytograms produced by the Advia 120 allowed recognition of artifactual changes in stored equine blood samples. These changes were less pronounced in samples stored at 24°C than at 4°C.

KW - Advia 120

KW - Artifact

KW - Ghost erythrocyte

KW - Horse

KW - Pseudothrombocytosis

UR - http://www.scopus.com/inward/record.url?scp=85039141845&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85039141845&partnerID=8YFLogxK

U2 - 10.1111/j.1939-165X.2002.tb00286.x

DO - 10.1111/j.1939-165X.2002.tb00286.x

M3 - Article

VL - 31

SP - 90

EP - 94

JO - Veterinary Clinical Pathology

JF - Veterinary Clinical Pathology

SN - 0275-6382

IS - 2

ER -