Hilar closure using staplers or Hem-o-lok clips in a rabbit model

Andrea L. Smith, Philipp Mayhew, Joao H. Soares, Philip H Kass, Robert J Brosnan

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Background: Lung lobectomy is necessary in neonatal patients for the treatment of a variety of congenital bronchopulmonary malformations. The working space required for traditional stapling devices limits their use in pediatric video-assisted thoracoscopic (VATS) lung lobectomy. The use of Hem-o-lok clips (Teleflex Medical Inc. Research Triangle Park, NC) has been described for a number of applications in minimally invasive surgery and may provide an alternative to traditional stapling devices for bronchial closure. Materials and methods: Twenty-four New Zealand White rabbits were used in the study. The hilus of each cranial lung lobe was sealed with the Endo GIA (Covidien Inc, Mansfield, MA) stapler or 2 Hem-o-lok clips and the lung lobe was removed. Lung inflation to leakage point was induced by incrementally increasing tidal volume. Side of leakage, volume at leakage, and airway pressure before leakage were recorded. Results: Fourteen rabbits were included in the data analysis. Leakage of air was first observed at the Hem-o-lok closure site in five rabbits and from the Endo GIA site in three rabbits. In the remaining six, both resection sites leaked simultaneously. The mean pressure before failure was 16.39 ± 7.35 mm Hg for the Hem-o-lok clips, 17.98 ± 11.12 mm Hg for the Endo GIA stapler, and 16.95 ± 3.48 mm Hg for the simultaneous failures. No statistical differences were detected in airways pressures before leakage between hilar closure devices. Conclusions: Despite advances in VATS, options for bronchial closure in pediatric patients undergoing VATS lung lobectomy remain limited. Hem-o-lok clips require less working space than traditional stapling devices and may represent an equally efficacious alternative to traditional stapling devices.

Original languageEnglish (US)
Pages (from-to)616-620
Number of pages5
JournalJournal of Surgical Research
Volume192
Issue number2
DOIs
StatePublished - Dec 1 2014

Fingerprint

Surgical Instruments
Rabbits
Lung
Equipment and Supplies
Pressure
Pediatrics
Minimally Invasive Surgical Procedures
Tidal Volume
Economic Inflation
Air
Research

Keywords

  • Airway
  • EndoGIA
  • Hem-o-lok
  • Lobectomy
  • Lung
  • Rabbit

ASJC Scopus subject areas

  • Surgery

Cite this

Hilar closure using staplers or Hem-o-lok clips in a rabbit model. / Smith, Andrea L.; Mayhew, Philipp; Soares, Joao H.; Kass, Philip H; Brosnan, Robert J.

In: Journal of Surgical Research, Vol. 192, No. 2, 01.12.2014, p. 616-620.

Research output: Contribution to journalArticle

@article{957c9b0795794832b45944b209630a81,
title = "Hilar closure using staplers or Hem-o-lok clips in a rabbit model",
abstract = "Background: Lung lobectomy is necessary in neonatal patients for the treatment of a variety of congenital bronchopulmonary malformations. The working space required for traditional stapling devices limits their use in pediatric video-assisted thoracoscopic (VATS) lung lobectomy. The use of Hem-o-lok clips (Teleflex Medical Inc. Research Triangle Park, NC) has been described for a number of applications in minimally invasive surgery and may provide an alternative to traditional stapling devices for bronchial closure. Materials and methods: Twenty-four New Zealand White rabbits were used in the study. The hilus of each cranial lung lobe was sealed with the Endo GIA (Covidien Inc, Mansfield, MA) stapler or 2 Hem-o-lok clips and the lung lobe was removed. Lung inflation to leakage point was induced by incrementally increasing tidal volume. Side of leakage, volume at leakage, and airway pressure before leakage were recorded. Results: Fourteen rabbits were included in the data analysis. Leakage of air was first observed at the Hem-o-lok closure site in five rabbits and from the Endo GIA site in three rabbits. In the remaining six, both resection sites leaked simultaneously. The mean pressure before failure was 16.39 ± 7.35 mm Hg for the Hem-o-lok clips, 17.98 ± 11.12 mm Hg for the Endo GIA stapler, and 16.95 ± 3.48 mm Hg for the simultaneous failures. No statistical differences were detected in airways pressures before leakage between hilar closure devices. Conclusions: Despite advances in VATS, options for bronchial closure in pediatric patients undergoing VATS lung lobectomy remain limited. Hem-o-lok clips require less working space than traditional stapling devices and may represent an equally efficacious alternative to traditional stapling devices.",
keywords = "Airway, EndoGIA, Hem-o-lok, Lobectomy, Lung, Rabbit",
author = "Smith, {Andrea L.} and Philipp Mayhew and Soares, {Joao H.} and Kass, {Philip H} and Brosnan, {Robert J}",
year = "2014",
month = "12",
day = "1",
doi = "10.1016/j.jss.2014.07.053",
language = "English (US)",
volume = "192",
pages = "616--620",
journal = "Journal of Surgical Research",
issn = "0022-4804",
publisher = "Academic Press Inc.",
number = "2",

}

TY - JOUR

T1 - Hilar closure using staplers or Hem-o-lok clips in a rabbit model

AU - Smith, Andrea L.

AU - Mayhew, Philipp

AU - Soares, Joao H.

AU - Kass, Philip H

AU - Brosnan, Robert J

PY - 2014/12/1

Y1 - 2014/12/1

N2 - Background: Lung lobectomy is necessary in neonatal patients for the treatment of a variety of congenital bronchopulmonary malformations. The working space required for traditional stapling devices limits their use in pediatric video-assisted thoracoscopic (VATS) lung lobectomy. The use of Hem-o-lok clips (Teleflex Medical Inc. Research Triangle Park, NC) has been described for a number of applications in minimally invasive surgery and may provide an alternative to traditional stapling devices for bronchial closure. Materials and methods: Twenty-four New Zealand White rabbits were used in the study. The hilus of each cranial lung lobe was sealed with the Endo GIA (Covidien Inc, Mansfield, MA) stapler or 2 Hem-o-lok clips and the lung lobe was removed. Lung inflation to leakage point was induced by incrementally increasing tidal volume. Side of leakage, volume at leakage, and airway pressure before leakage were recorded. Results: Fourteen rabbits were included in the data analysis. Leakage of air was first observed at the Hem-o-lok closure site in five rabbits and from the Endo GIA site in three rabbits. In the remaining six, both resection sites leaked simultaneously. The mean pressure before failure was 16.39 ± 7.35 mm Hg for the Hem-o-lok clips, 17.98 ± 11.12 mm Hg for the Endo GIA stapler, and 16.95 ± 3.48 mm Hg for the simultaneous failures. No statistical differences were detected in airways pressures before leakage between hilar closure devices. Conclusions: Despite advances in VATS, options for bronchial closure in pediatric patients undergoing VATS lung lobectomy remain limited. Hem-o-lok clips require less working space than traditional stapling devices and may represent an equally efficacious alternative to traditional stapling devices.

AB - Background: Lung lobectomy is necessary in neonatal patients for the treatment of a variety of congenital bronchopulmonary malformations. The working space required for traditional stapling devices limits their use in pediatric video-assisted thoracoscopic (VATS) lung lobectomy. The use of Hem-o-lok clips (Teleflex Medical Inc. Research Triangle Park, NC) has been described for a number of applications in minimally invasive surgery and may provide an alternative to traditional stapling devices for bronchial closure. Materials and methods: Twenty-four New Zealand White rabbits were used in the study. The hilus of each cranial lung lobe was sealed with the Endo GIA (Covidien Inc, Mansfield, MA) stapler or 2 Hem-o-lok clips and the lung lobe was removed. Lung inflation to leakage point was induced by incrementally increasing tidal volume. Side of leakage, volume at leakage, and airway pressure before leakage were recorded. Results: Fourteen rabbits were included in the data analysis. Leakage of air was first observed at the Hem-o-lok closure site in five rabbits and from the Endo GIA site in three rabbits. In the remaining six, both resection sites leaked simultaneously. The mean pressure before failure was 16.39 ± 7.35 mm Hg for the Hem-o-lok clips, 17.98 ± 11.12 mm Hg for the Endo GIA stapler, and 16.95 ± 3.48 mm Hg for the simultaneous failures. No statistical differences were detected in airways pressures before leakage between hilar closure devices. Conclusions: Despite advances in VATS, options for bronchial closure in pediatric patients undergoing VATS lung lobectomy remain limited. Hem-o-lok clips require less working space than traditional stapling devices and may represent an equally efficacious alternative to traditional stapling devices.

KW - Airway

KW - EndoGIA

KW - Hem-o-lok

KW - Lobectomy

KW - Lung

KW - Rabbit

UR - http://www.scopus.com/inward/record.url?scp=84912005490&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84912005490&partnerID=8YFLogxK

U2 - 10.1016/j.jss.2014.07.053

DO - 10.1016/j.jss.2014.07.053

M3 - Article

C2 - 25167784

AN - SCOPUS:84912005490

VL - 192

SP - 616

EP - 620

JO - Journal of Surgical Research

JF - Journal of Surgical Research

SN - 0022-4804

IS - 2

ER -