Abstract

We describe recently developed oblique-incidence reflectivity difference microscopes, a form of polarization-modulated imaging ellipsometry, for label-free detection of biochemical reactions in microarrays. Configurations enabling high-throughput endpoint and real-time detection on glass substrates are discussed.

Original languageEnglish (US)
Title of host publicationConference on Lasers and Electro-Optics, 2007, CLEO 2007
DOIs
StatePublished - 2007
EventConference on Lasers and Electro-Optics, 2007, CLEO 2007 - Baltimore, MD, United States
Duration: May 6 2007May 11 2007

Other

OtherConference on Lasers and Electro-Optics, 2007, CLEO 2007
CountryUnited States
CityBaltimore, MD
Period5/6/075/11/07

Fingerprint

Ellipsometry
Microarrays
Labels
Microscopes
Throughput
Polarization
Imaging techniques
Glass
Substrates

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials

Cite this

High-throughput endpoint and real-time detection of biochemical reactions in microarrays using label-free oblique-incidence reflectivity difference microscopes. / Landry, J. P.; Sun, Y. S.; Lam, Kit; Zhu, X. D.

Conference on Lasers and Electro-Optics, 2007, CLEO 2007. 2007. 4453099.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Landry, JP, Sun, YS, Lam, K & Zhu, XD 2007, High-throughput endpoint and real-time detection of biochemical reactions in microarrays using label-free oblique-incidence reflectivity difference microscopes. in Conference on Lasers and Electro-Optics, 2007, CLEO 2007., 4453099, Conference on Lasers and Electro-Optics, 2007, CLEO 2007, Baltimore, MD, United States, 5/6/07. https://doi.org/10.1109/CLEO.2007.4453099
@inproceedings{4ef1d151e01045d69601f37e12d6614b,
title = "High-throughput endpoint and real-time detection of biochemical reactions in microarrays using label-free oblique-incidence reflectivity difference microscopes",
abstract = "We describe recently developed oblique-incidence reflectivity difference microscopes, a form of polarization-modulated imaging ellipsometry, for label-free detection of biochemical reactions in microarrays. Configurations enabling high-throughput endpoint and real-time detection on glass substrates are discussed.",
author = "Landry, {J. P.} and Sun, {Y. S.} and Kit Lam and Zhu, {X. D.}",
year = "2007",
doi = "10.1109/CLEO.2007.4453099",
language = "English (US)",
isbn = "9781557528346",
booktitle = "Conference on Lasers and Electro-Optics, 2007, CLEO 2007",

}

TY - GEN

T1 - High-throughput endpoint and real-time detection of biochemical reactions in microarrays using label-free oblique-incidence reflectivity difference microscopes

AU - Landry, J. P.

AU - Sun, Y. S.

AU - Lam, Kit

AU - Zhu, X. D.

PY - 2007

Y1 - 2007

N2 - We describe recently developed oblique-incidence reflectivity difference microscopes, a form of polarization-modulated imaging ellipsometry, for label-free detection of biochemical reactions in microarrays. Configurations enabling high-throughput endpoint and real-time detection on glass substrates are discussed.

AB - We describe recently developed oblique-incidence reflectivity difference microscopes, a form of polarization-modulated imaging ellipsometry, for label-free detection of biochemical reactions in microarrays. Configurations enabling high-throughput endpoint and real-time detection on glass substrates are discussed.

UR - http://www.scopus.com/inward/record.url?scp=82955228054&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=82955228054&partnerID=8YFLogxK

U2 - 10.1109/CLEO.2007.4453099

DO - 10.1109/CLEO.2007.4453099

M3 - Conference contribution

SN - 9781557528346

BT - Conference on Lasers and Electro-Optics, 2007, CLEO 2007

ER -