High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children

Zhensheng Chen, Ian J. Griffin, Lora M. Plumlee, Steven A. Abrams

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICP-MS) may permit more cost-efficient sample analysis due to its high through-put, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given 58Fe and 57Fe were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7% (1 SD) for 57Fe/54Fe and 58Fe/54Fe, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICP-MS. A 2-μL RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5% and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.

Original languageEnglish (US)
Pages (from-to)1790-1795
Number of pages6
JournalJournal of Nutrition
Volume135
Issue number7
StatePublished - Jul 2005
Externally publishedYes

Fingerprint

Iron Isotopes
iron absorption
atomic absorption spectrometry
Mass Spectrometry
Iron
isotopes
iron
Hot Temperature
Isotopes
ionization
Nickel
Costs and Cost Analysis
nickel
heat
stable isotopes
Blood Volume
Calibration
sampling
methodology
blood volume

Keywords

  • Inductively coupled plasma MS
  • Iron absorption
  • Isobaric interference
  • Mass bias
  • Stable isotopes

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Food Science

Cite this

High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children. / Chen, Zhensheng; Griffin, Ian J.; Plumlee, Lora M.; Abrams, Steven A.

In: Journal of Nutrition, Vol. 135, No. 7, 07.2005, p. 1790-1795.

Research output: Contribution to journalArticle

Chen, Zhensheng ; Griffin, Ian J. ; Plumlee, Lora M. ; Abrams, Steven A. / High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children. In: Journal of Nutrition. 2005 ; Vol. 135, No. 7. pp. 1790-1795.
@article{b119670a7ec544ba974a9e059ddba0b3,
title = "High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children",
abstract = "Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICP-MS) may permit more cost-efficient sample analysis due to its high through-put, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given 58Fe and 57Fe were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7{\%} (1 SD) for 57Fe/54Fe and 58Fe/54Fe, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICP-MS. A 2-μL RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5{\%} and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.",
keywords = "Inductively coupled plasma MS, Iron absorption, Isobaric interference, Mass bias, Stable isotopes",
author = "Zhensheng Chen and Griffin, {Ian J.} and Plumlee, {Lora M.} and Abrams, {Steven A.}",
year = "2005",
month = "7",
language = "English (US)",
volume = "135",
pages = "1790--1795",
journal = "Journal of Nutrition",
issn = "0022-3166",
publisher = "American Society for Nutrition",
number = "7",

}

TY - JOUR

T1 - High resolution inductively coupled plasma mass spectrometry allows rapid assessment of iron absorption in infants and children

AU - Chen, Zhensheng

AU - Griffin, Ian J.

AU - Plumlee, Lora M.

AU - Abrams, Steven A.

PY - 2005/7

Y1 - 2005/7

N2 - Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICP-MS) may permit more cost-efficient sample analysis due to its high through-put, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given 58Fe and 57Fe were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7% (1 SD) for 57Fe/54Fe and 58Fe/54Fe, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICP-MS. A 2-μL RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5% and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.

AB - Stable isotope absorption studies of iron have been limited by the high cost and limited availability of isotope ratio analysis using thermal ionization MS (TIMS). The development of high-resolution double focusing inductively coupled plasma MS (ICP-MS) may permit more cost-efficient sample analysis due to its high through-put, lower cost, easy sample pretreatment, and greater availability. Our objective was to develop an ICP-MS methodology for the measurement of iron isotope ratios using very small blood volumes. We developed a technique using multiple iron-nickel mixing standard solutions to adjust for nickel interference calibration. RBC samples from human subjects previously given 58Fe and 57Fe were analyzed for iron isotope ratios and compared with our current methodology (TIMS). Reproducibility of iron isotope ratios provided external relative SD < 0.5 and 0.7% (1 SD) for 57Fe/54Fe and 58Fe/54Fe, respectively. Iron isotope ratios from ICP-MS analysis did not differ from those from TIMS based on statistical analyses, nor did the calculated iron absorption values. The mean and SD of iron absorption did not differ when measured by TIMS or ICP-MS. A 2-μL RBC sample was sufficient for ICP-MS iron isotope ratio analysis with an internal relative SD < 0.5% and analytical time < 5 min. This technique may assist groups in increasing their use of stable isotope methods to assess iron absorption in infants and children.

KW - Inductively coupled plasma MS

KW - Iron absorption

KW - Isobaric interference

KW - Mass bias

KW - Stable isotopes

UR - http://www.scopus.com/inward/record.url?scp=22144461769&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=22144461769&partnerID=8YFLogxK

M3 - Article

VL - 135

SP - 1790

EP - 1795

JO - Journal of Nutrition

JF - Journal of Nutrition

SN - 0022-3166

IS - 7

ER -