Headless Compression Screw Fixation of Vertical Medial Malleolus Fractures is Superior to Unicortical Screw Fixation

Adam M. Wegner, Philip R Wolinsky, Michael A. Robbins, Tanya C. Garcia, Sukanta Maitra, Derek F. Amanatullah

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This study is the first biomechanical research of headless compression screws for fixation of vertical shear fractures of the medial malleolus, a promising alternative that potentially offers several advantages for fixation. Vertical shear fractures were simulated by osteotomies in 20 synthetic distal tibiae. Models were randomly assigned to fixation with either 2 parallel cancellous screws or 2 parallel Acutrak 2 headless compression screws (Acumed). Specimens were subjected to offset axial loading to simulate supination-adduction loading and tracked using high-resolution video. The headless compression screw construct was significantly stiffer (P < .0001) (360 ± 131 N/mm) than the partially threaded cancellous screws (180 ± 48 N/mm) and demonstrated a significantly increased (P < .0001) mean load to clinical failure (719 ± 91 N vs 343 ± 83 N). When specimens were displaced to 6 mm and allowed to relax, the headless compression screw constructs demonstrated an elastic recoil and were reduced to the pretesting fragment alignment, whereas the parallel cancellous screw constructs remained displaced. Along with the headless design that may decrease soft tissue irritation, the increased stiffness and elastic recoil of the headless compression screw construct offers improved fixation of medial malleolus vertical shear fractures over the traditional methods.

Original languageEnglish (US)
JournalAmerican journal of orthopedics (Belle Mead, N.J.)
Volume47
Issue number8
DOIs
StatePublished - Aug 1 2018

Fingerprint

Ankle Fractures
Supination
Weight-Bearing
Osteotomy
Tibia
Research

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Headless Compression Screw Fixation of Vertical Medial Malleolus Fractures is Superior to Unicortical Screw Fixation. / Wegner, Adam M.; Wolinsky, Philip R; Robbins, Michael A.; Garcia, Tanya C.; Maitra, Sukanta; Amanatullah, Derek F.

In: American journal of orthopedics (Belle Mead, N.J.), Vol. 47, No. 8, 01.08.2018.

Research output: Contribution to journalArticle

Wegner, Adam M. ; Wolinsky, Philip R ; Robbins, Michael A. ; Garcia, Tanya C. ; Maitra, Sukanta ; Amanatullah, Derek F. / Headless Compression Screw Fixation of Vertical Medial Malleolus Fractures is Superior to Unicortical Screw Fixation. In: American journal of orthopedics (Belle Mead, N.J.). 2018 ; Vol. 47, No. 8.
@article{f37c6dbb9130423389884c5263e6bb34,
title = "Headless Compression Screw Fixation of Vertical Medial Malleolus Fractures is Superior to Unicortical Screw Fixation",
abstract = "This study is the first biomechanical research of headless compression screws for fixation of vertical shear fractures of the medial malleolus, a promising alternative that potentially offers several advantages for fixation. Vertical shear fractures were simulated by osteotomies in 20 synthetic distal tibiae. Models were randomly assigned to fixation with either 2 parallel cancellous screws or 2 parallel Acutrak 2 headless compression screws (Acumed). Specimens were subjected to offset axial loading to simulate supination-adduction loading and tracked using high-resolution video. The headless compression screw construct was significantly stiffer (P < .0001) (360 ± 131 N/mm) than the partially threaded cancellous screws (180 ± 48 N/mm) and demonstrated a significantly increased (P < .0001) mean load to clinical failure (719 ± 91 N vs 343 ± 83 N). When specimens were displaced to 6 mm and allowed to relax, the headless compression screw constructs demonstrated an elastic recoil and were reduced to the pretesting fragment alignment, whereas the parallel cancellous screw constructs remained displaced. Along with the headless design that may decrease soft tissue irritation, the increased stiffness and elastic recoil of the headless compression screw construct offers improved fixation of medial malleolus vertical shear fractures over the traditional methods.",
author = "Wegner, {Adam M.} and Wolinsky, {Philip R} and Robbins, {Michael A.} and Garcia, {Tanya C.} and Sukanta Maitra and Amanatullah, {Derek F.}",
year = "2018",
month = "8",
day = "1",
doi = "10.12788/ajo.2018.0066",
language = "English (US)",
volume = "47",
journal = "American Journal of Orthopedics",
issn = "1078-4519",
publisher = "Quadrant Healthcom Inc.",
number = "8",

}

TY - JOUR

T1 - Headless Compression Screw Fixation of Vertical Medial Malleolus Fractures is Superior to Unicortical Screw Fixation

AU - Wegner, Adam M.

AU - Wolinsky, Philip R

AU - Robbins, Michael A.

AU - Garcia, Tanya C.

AU - Maitra, Sukanta

AU - Amanatullah, Derek F.

PY - 2018/8/1

Y1 - 2018/8/1

N2 - This study is the first biomechanical research of headless compression screws for fixation of vertical shear fractures of the medial malleolus, a promising alternative that potentially offers several advantages for fixation. Vertical shear fractures were simulated by osteotomies in 20 synthetic distal tibiae. Models were randomly assigned to fixation with either 2 parallel cancellous screws or 2 parallel Acutrak 2 headless compression screws (Acumed). Specimens were subjected to offset axial loading to simulate supination-adduction loading and tracked using high-resolution video. The headless compression screw construct was significantly stiffer (P < .0001) (360 ± 131 N/mm) than the partially threaded cancellous screws (180 ± 48 N/mm) and demonstrated a significantly increased (P < .0001) mean load to clinical failure (719 ± 91 N vs 343 ± 83 N). When specimens were displaced to 6 mm and allowed to relax, the headless compression screw constructs demonstrated an elastic recoil and were reduced to the pretesting fragment alignment, whereas the parallel cancellous screw constructs remained displaced. Along with the headless design that may decrease soft tissue irritation, the increased stiffness and elastic recoil of the headless compression screw construct offers improved fixation of medial malleolus vertical shear fractures over the traditional methods.

AB - This study is the first biomechanical research of headless compression screws for fixation of vertical shear fractures of the medial malleolus, a promising alternative that potentially offers several advantages for fixation. Vertical shear fractures were simulated by osteotomies in 20 synthetic distal tibiae. Models were randomly assigned to fixation with either 2 parallel cancellous screws or 2 parallel Acutrak 2 headless compression screws (Acumed). Specimens were subjected to offset axial loading to simulate supination-adduction loading and tracked using high-resolution video. The headless compression screw construct was significantly stiffer (P < .0001) (360 ± 131 N/mm) than the partially threaded cancellous screws (180 ± 48 N/mm) and demonstrated a significantly increased (P < .0001) mean load to clinical failure (719 ± 91 N vs 343 ± 83 N). When specimens were displaced to 6 mm and allowed to relax, the headless compression screw constructs demonstrated an elastic recoil and were reduced to the pretesting fragment alignment, whereas the parallel cancellous screw constructs remained displaced. Along with the headless design that may decrease soft tissue irritation, the increased stiffness and elastic recoil of the headless compression screw construct offers improved fixation of medial malleolus vertical shear fractures over the traditional methods.

UR - http://www.scopus.com/inward/record.url?scp=85059798276&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059798276&partnerID=8YFLogxK

U2 - 10.12788/ajo.2018.0066

DO - 10.12788/ajo.2018.0066

M3 - Article

C2 - 30180221

AN - SCOPUS:85059798276

VL - 47

JO - American Journal of Orthopedics

JF - American Journal of Orthopedics

SN - 1078-4519

IS - 8

ER -