Giant two-dimensional gel electrophoresis: Methodological update and comparison with intermediate-format gel systems

Richard M Levenson, G. M. Anderson, J. A. Cohn, P. J. Blackshear

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Two-dimensional (2-D) gel electrophoresis methods for separating complex mixtures of proteins have not changed fundamentally since their original description in the late 1970's. Nevertheless, 2-D gel resolution has improved substantially as a result of a series of incremental modifications. One of these was the development of the ''gaint-gel'' format, using gels measuring at least 30 x 30 cm to provide the highest resolution 2-D gel system available. As originally described, this procedure has several important limitations: it requires custom-built equipment; it is expensive in terms of time, reagents, film and support matrices; and it generates gels which are difficult to manupulate, particularly for silver staining. This report describes modifications in the giant gel procedure to permit use of a commercially available gel apparatus and to obtain giant gels of improved mechanical strength suitable for silver staining. The resolution of giant gels is compared with that obtained using two systems currently being marketed for use by laboratories performing large numbers of 2-D gel analyses. The smaller format gels resolved fewer proteins, by 30-40%, compared with the giant gels. This difference in resolving power suggests that giant gels will continue to be useful in selected applications.

Original languageEnglish (US)
Pages (from-to)269-279
Number of pages11
JournalElectrophoresis
Volume11
Issue number3
DOIs
StatePublished - 1990
Externally publishedYes

Fingerprint

Electrophoresis, Gel, Two-Dimensional
Electrophoresis
Gels
Silver Staining
Silver
Optical resolving power
Complex Mixtures
Strength of materials
Proteins

ASJC Scopus subject areas

  • Clinical Biochemistry

Cite this

Giant two-dimensional gel electrophoresis : Methodological update and comparison with intermediate-format gel systems. / Levenson, Richard M; Anderson, G. M.; Cohn, J. A.; Blackshear, P. J.

In: Electrophoresis, Vol. 11, No. 3, 1990, p. 269-279.

Research output: Contribution to journalArticle

@article{ddae04c357584b80b7dd665746db1667,
title = "Giant two-dimensional gel electrophoresis: Methodological update and comparison with intermediate-format gel systems",
abstract = "Two-dimensional (2-D) gel electrophoresis methods for separating complex mixtures of proteins have not changed fundamentally since their original description in the late 1970's. Nevertheless, 2-D gel resolution has improved substantially as a result of a series of incremental modifications. One of these was the development of the ''gaint-gel'' format, using gels measuring at least 30 x 30 cm to provide the highest resolution 2-D gel system available. As originally described, this procedure has several important limitations: it requires custom-built equipment; it is expensive in terms of time, reagents, film and support matrices; and it generates gels which are difficult to manupulate, particularly for silver staining. This report describes modifications in the giant gel procedure to permit use of a commercially available gel apparatus and to obtain giant gels of improved mechanical strength suitable for silver staining. The resolution of giant gels is compared with that obtained using two systems currently being marketed for use by laboratories performing large numbers of 2-D gel analyses. The smaller format gels resolved fewer proteins, by 30-40{\%}, compared with the giant gels. This difference in resolving power suggests that giant gels will continue to be useful in selected applications.",
author = "Levenson, {Richard M} and Anderson, {G. M.} and Cohn, {J. A.} and Blackshear, {P. J.}",
year = "1990",
doi = "10.1002/elps.1150110310",
language = "English (US)",
volume = "11",
pages = "269--279",
journal = "Electrophoresis",
issn = "0173-0835",
publisher = "Wiley-VCH Verlag",
number = "3",

}

TY - JOUR

T1 - Giant two-dimensional gel electrophoresis

T2 - Methodological update and comparison with intermediate-format gel systems

AU - Levenson, Richard M

AU - Anderson, G. M.

AU - Cohn, J. A.

AU - Blackshear, P. J.

PY - 1990

Y1 - 1990

N2 - Two-dimensional (2-D) gel electrophoresis methods for separating complex mixtures of proteins have not changed fundamentally since their original description in the late 1970's. Nevertheless, 2-D gel resolution has improved substantially as a result of a series of incremental modifications. One of these was the development of the ''gaint-gel'' format, using gels measuring at least 30 x 30 cm to provide the highest resolution 2-D gel system available. As originally described, this procedure has several important limitations: it requires custom-built equipment; it is expensive in terms of time, reagents, film and support matrices; and it generates gels which are difficult to manupulate, particularly for silver staining. This report describes modifications in the giant gel procedure to permit use of a commercially available gel apparatus and to obtain giant gels of improved mechanical strength suitable for silver staining. The resolution of giant gels is compared with that obtained using two systems currently being marketed for use by laboratories performing large numbers of 2-D gel analyses. The smaller format gels resolved fewer proteins, by 30-40%, compared with the giant gels. This difference in resolving power suggests that giant gels will continue to be useful in selected applications.

AB - Two-dimensional (2-D) gel electrophoresis methods for separating complex mixtures of proteins have not changed fundamentally since their original description in the late 1970's. Nevertheless, 2-D gel resolution has improved substantially as a result of a series of incremental modifications. One of these was the development of the ''gaint-gel'' format, using gels measuring at least 30 x 30 cm to provide the highest resolution 2-D gel system available. As originally described, this procedure has several important limitations: it requires custom-built equipment; it is expensive in terms of time, reagents, film and support matrices; and it generates gels which are difficult to manupulate, particularly for silver staining. This report describes modifications in the giant gel procedure to permit use of a commercially available gel apparatus and to obtain giant gels of improved mechanical strength suitable for silver staining. The resolution of giant gels is compared with that obtained using two systems currently being marketed for use by laboratories performing large numbers of 2-D gel analyses. The smaller format gels resolved fewer proteins, by 30-40%, compared with the giant gels. This difference in resolving power suggests that giant gels will continue to be useful in selected applications.

UR - http://www.scopus.com/inward/record.url?scp=0025277304&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025277304&partnerID=8YFLogxK

U2 - 10.1002/elps.1150110310

DO - 10.1002/elps.1150110310

M3 - Article

C2 - 1693119

AN - SCOPUS:0025277304

VL - 11

SP - 269

EP - 279

JO - Electrophoresis

JF - Electrophoresis

SN - 0173-0835

IS - 3

ER -