Evaluation of image quality of a new CCD-based system for chest imaging

Patrik Sund, Magnus Bath, Susanne Kheddache, Ulf Tylen, Lars Gunnar Mansson

Research output: Chapter in Book/Report/Conference proceedingConference contribution

24 Citations (Scopus)

Abstract

The Imix radiography system (Oy Imix Ab, Finland) consists of an intensifying screen, optics, and a CCD camera. An upgrade of this system (Imix 2000) with a red-emitting screen and new optics has recently been released. The image quality of Imix (original version), Imix 2000, and two storage-phosphor systems, Fuji FCR 9501 and Agfa ADC70 was evaluated in physical terms (DQE) and with visual grading of the visibility of anatomical structures in clinical images (141 kV). PA chest images of 50 healthy volunteers were evaluated by experienced radiologists. All images were evaluated on Siemens Simomed monitors, using the European Quality Criteria. The maximum DQE values for Imix, Imix 2000, Agfa and Fuji were 11%, 14%, 17% and 19%, respectively (141 kV, 5 μGy). Using the visual grading, the observers rated the systems in the following descending order: Fuji, Imix 2000, Agfa, and Imix. Thus, the upgrade to Imix 2000 resulted in higher DQE values and a significant improvement in clinical image quality. The visual grading agrees reasonably well with the DQE results; however, Imix 2000, received a better score than what could be expected from the DQE measurements.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
PublisherSociety of Photo-Optical Instrumentation Engineers
Pages251-258
Number of pages8
Volume3981
StatePublished - 2000
Externally publishedYes
EventMedical Imaging 2000: Image Perception and Performance - San Diego, CA, USA
Duration: Feb 16 2000Feb 17 2000

Other

OtherMedical Imaging 2000: Image Perception and Performance
CitySan Diego, CA, USA
Period2/16/002/17/00

Fingerprint

chest
Charge coupled devices
Image quality
charge coupled devices
Imaging techniques
evaluation
Optics
Radiography
CCD cameras
Visibility
Phosphors
optics
Finland
radiography
visibility
phosphors
monitors

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

Sund, P., Bath, M., Kheddache, S., Tylen, U., & Mansson, L. G. (2000). Evaluation of image quality of a new CCD-based system for chest imaging. In Proceedings of SPIE - The International Society for Optical Engineering (Vol. 3981, pp. 251-258). Society of Photo-Optical Instrumentation Engineers.

Evaluation of image quality of a new CCD-based system for chest imaging. / Sund, Patrik; Bath, Magnus; Kheddache, Susanne; Tylen, Ulf; Mansson, Lars Gunnar.

Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3981 Society of Photo-Optical Instrumentation Engineers, 2000. p. 251-258.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Sund, P, Bath, M, Kheddache, S, Tylen, U & Mansson, LG 2000, Evaluation of image quality of a new CCD-based system for chest imaging. in Proceedings of SPIE - The International Society for Optical Engineering. vol. 3981, Society of Photo-Optical Instrumentation Engineers, pp. 251-258, Medical Imaging 2000: Image Perception and Performance, San Diego, CA, USA, 2/16/00.
Sund P, Bath M, Kheddache S, Tylen U, Mansson LG. Evaluation of image quality of a new CCD-based system for chest imaging. In Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3981. Society of Photo-Optical Instrumentation Engineers. 2000. p. 251-258
Sund, Patrik ; Bath, Magnus ; Kheddache, Susanne ; Tylen, Ulf ; Mansson, Lars Gunnar. / Evaluation of image quality of a new CCD-based system for chest imaging. Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3981 Society of Photo-Optical Instrumentation Engineers, 2000. pp. 251-258
@inproceedings{4ea5b88897d643bc970a9347df619263,
title = "Evaluation of image quality of a new CCD-based system for chest imaging",
abstract = "The Imix radiography system (Oy Imix Ab, Finland) consists of an intensifying screen, optics, and a CCD camera. An upgrade of this system (Imix 2000) with a red-emitting screen and new optics has recently been released. The image quality of Imix (original version), Imix 2000, and two storage-phosphor systems, Fuji FCR 9501 and Agfa ADC70 was evaluated in physical terms (DQE) and with visual grading of the visibility of anatomical structures in clinical images (141 kV). PA chest images of 50 healthy volunteers were evaluated by experienced radiologists. All images were evaluated on Siemens Simomed monitors, using the European Quality Criteria. The maximum DQE values for Imix, Imix 2000, Agfa and Fuji were 11{\%}, 14{\%}, 17{\%} and 19{\%}, respectively (141 kV, 5 μGy). Using the visual grading, the observers rated the systems in the following descending order: Fuji, Imix 2000, Agfa, and Imix. Thus, the upgrade to Imix 2000 resulted in higher DQE values and a significant improvement in clinical image quality. The visual grading agrees reasonably well with the DQE results; however, Imix 2000, received a better score than what could be expected from the DQE measurements.",
author = "Patrik Sund and Magnus Bath and Susanne Kheddache and Ulf Tylen and Mansson, {Lars Gunnar}",
year = "2000",
language = "English (US)",
volume = "3981",
pages = "251--258",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "Society of Photo-Optical Instrumentation Engineers",

}

TY - GEN

T1 - Evaluation of image quality of a new CCD-based system for chest imaging

AU - Sund, Patrik

AU - Bath, Magnus

AU - Kheddache, Susanne

AU - Tylen, Ulf

AU - Mansson, Lars Gunnar

PY - 2000

Y1 - 2000

N2 - The Imix radiography system (Oy Imix Ab, Finland) consists of an intensifying screen, optics, and a CCD camera. An upgrade of this system (Imix 2000) with a red-emitting screen and new optics has recently been released. The image quality of Imix (original version), Imix 2000, and two storage-phosphor systems, Fuji FCR 9501 and Agfa ADC70 was evaluated in physical terms (DQE) and with visual grading of the visibility of anatomical structures in clinical images (141 kV). PA chest images of 50 healthy volunteers were evaluated by experienced radiologists. All images were evaluated on Siemens Simomed monitors, using the European Quality Criteria. The maximum DQE values for Imix, Imix 2000, Agfa and Fuji were 11%, 14%, 17% and 19%, respectively (141 kV, 5 μGy). Using the visual grading, the observers rated the systems in the following descending order: Fuji, Imix 2000, Agfa, and Imix. Thus, the upgrade to Imix 2000 resulted in higher DQE values and a significant improvement in clinical image quality. The visual grading agrees reasonably well with the DQE results; however, Imix 2000, received a better score than what could be expected from the DQE measurements.

AB - The Imix radiography system (Oy Imix Ab, Finland) consists of an intensifying screen, optics, and a CCD camera. An upgrade of this system (Imix 2000) with a red-emitting screen and new optics has recently been released. The image quality of Imix (original version), Imix 2000, and two storage-phosphor systems, Fuji FCR 9501 and Agfa ADC70 was evaluated in physical terms (DQE) and with visual grading of the visibility of anatomical structures in clinical images (141 kV). PA chest images of 50 healthy volunteers were evaluated by experienced radiologists. All images were evaluated on Siemens Simomed monitors, using the European Quality Criteria. The maximum DQE values for Imix, Imix 2000, Agfa and Fuji were 11%, 14%, 17% and 19%, respectively (141 kV, 5 μGy). Using the visual grading, the observers rated the systems in the following descending order: Fuji, Imix 2000, Agfa, and Imix. Thus, the upgrade to Imix 2000 resulted in higher DQE values and a significant improvement in clinical image quality. The visual grading agrees reasonably well with the DQE results; however, Imix 2000, received a better score than what could be expected from the DQE measurements.

UR - http://www.scopus.com/inward/record.url?scp=0033743026&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033743026&partnerID=8YFLogxK

M3 - Conference contribution

VL - 3981

SP - 251

EP - 258

BT - Proceedings of SPIE - The International Society for Optical Engineering

PB - Society of Photo-Optical Instrumentation Engineers

ER -