Evaluation of goniometry and electrogoniometry of carpus and elbow joints in the barred owl (strix varia)

Jenessa Gjeltema, Laurel A. Degernes, Halley D. Buckanoff, Denis J Marcellin-Little

Research output: Contribution to journalArticle

Abstract

The motion of wing joints is a critical factor for successful flight in avian patients, but little information is available about goniometry in birds. Elbow and carpus joints in flexed and extended positions from 10 orthopedically normal wings of 6 adult wild barred owls (Strix varia) were evaluated with the animals under general anesthesia using a modified universal plastic goniometer and an electrogoniometer. These measurements were compared to those obtained using radiographic assessment. Intra-and interobserver reliability was calculated. Measurements in live animals were compared to those obtained from frozen-thawed carcasses. Results showed that the modified universal plastic goniometer can be used to obtain accurate results for elbow flexion and extension and for carpal flexion with good to excellent reliability compared to measurements collected from radiographic assessment. Measurements obtained using an electrogoniometer were less accurate and less reliable than those obtained with a plastic goniometer, possibly because of the size and configuration of the model used. Comparison of measurements from live animals and carcasses revealed no significant differences between mean measurements and suggested that further evaluation of carcasses as a model for study of goniometry measurements in avian wing joints should be considered.

Original languageEnglish (US)
Pages (from-to)267-278
Number of pages12
JournalJournal of Avian Medicine and Surgery
Volume32
Issue number4
DOIs
StatePublished - Dec 1 2018

Fingerprint

Strigiformes
Strix
Elbow Joint
carpus
elbows
joints (animal)
Plastics
Joints
Elbow
Wrist
plastics
General Anesthesia
Birds
carcass evaluation
animals
anesthesia
flight
birds

Keywords

  • Avian
  • Barred owl
  • Electrogoniometry
  • Goniometry
  • Joint Angle
  • Range of motion
  • Strix varia

ASJC Scopus subject areas

  • Small Animals

Cite this

Evaluation of goniometry and electrogoniometry of carpus and elbow joints in the barred owl (strix varia). / Gjeltema, Jenessa; Degernes, Laurel A.; Buckanoff, Halley D.; Marcellin-Little, Denis J.

In: Journal of Avian Medicine and Surgery, Vol. 32, No. 4, 01.12.2018, p. 267-278.

Research output: Contribution to journalArticle

@article{d0fb055cc63448fba2fd3080ea85bb71,
title = "Evaluation of goniometry and electrogoniometry of carpus and elbow joints in the barred owl (strix varia)",
abstract = "The motion of wing joints is a critical factor for successful flight in avian patients, but little information is available about goniometry in birds. Elbow and carpus joints in flexed and extended positions from 10 orthopedically normal wings of 6 adult wild barred owls (Strix varia) were evaluated with the animals under general anesthesia using a modified universal plastic goniometer and an electrogoniometer. These measurements were compared to those obtained using radiographic assessment. Intra-and interobserver reliability was calculated. Measurements in live animals were compared to those obtained from frozen-thawed carcasses. Results showed that the modified universal plastic goniometer can be used to obtain accurate results for elbow flexion and extension and for carpal flexion with good to excellent reliability compared to measurements collected from radiographic assessment. Measurements obtained using an electrogoniometer were less accurate and less reliable than those obtained with a plastic goniometer, possibly because of the size and configuration of the model used. Comparison of measurements from live animals and carcasses revealed no significant differences between mean measurements and suggested that further evaluation of carcasses as a model for study of goniometry measurements in avian wing joints should be considered.",
keywords = "Avian, Barred owl, Electrogoniometry, Goniometry, Joint Angle, Range of motion, Strix varia",
author = "Jenessa Gjeltema and Degernes, {Laurel A.} and Buckanoff, {Halley D.} and Marcellin-Little, {Denis J}",
year = "2018",
month = "12",
day = "1",
doi = "10.1647/2017-311",
language = "English (US)",
volume = "32",
pages = "267--278",
journal = "Journal of Avian Medicine and Surgery",
issn = "1082-6742",
publisher = "Association of Avian Veterinarians",
number = "4",

}

TY - JOUR

T1 - Evaluation of goniometry and electrogoniometry of carpus and elbow joints in the barred owl (strix varia)

AU - Gjeltema, Jenessa

AU - Degernes, Laurel A.

AU - Buckanoff, Halley D.

AU - Marcellin-Little, Denis J

PY - 2018/12/1

Y1 - 2018/12/1

N2 - The motion of wing joints is a critical factor for successful flight in avian patients, but little information is available about goniometry in birds. Elbow and carpus joints in flexed and extended positions from 10 orthopedically normal wings of 6 adult wild barred owls (Strix varia) were evaluated with the animals under general anesthesia using a modified universal plastic goniometer and an electrogoniometer. These measurements were compared to those obtained using radiographic assessment. Intra-and interobserver reliability was calculated. Measurements in live animals were compared to those obtained from frozen-thawed carcasses. Results showed that the modified universal plastic goniometer can be used to obtain accurate results for elbow flexion and extension and for carpal flexion with good to excellent reliability compared to measurements collected from radiographic assessment. Measurements obtained using an electrogoniometer were less accurate and less reliable than those obtained with a plastic goniometer, possibly because of the size and configuration of the model used. Comparison of measurements from live animals and carcasses revealed no significant differences between mean measurements and suggested that further evaluation of carcasses as a model for study of goniometry measurements in avian wing joints should be considered.

AB - The motion of wing joints is a critical factor for successful flight in avian patients, but little information is available about goniometry in birds. Elbow and carpus joints in flexed and extended positions from 10 orthopedically normal wings of 6 adult wild barred owls (Strix varia) were evaluated with the animals under general anesthesia using a modified universal plastic goniometer and an electrogoniometer. These measurements were compared to those obtained using radiographic assessment. Intra-and interobserver reliability was calculated. Measurements in live animals were compared to those obtained from frozen-thawed carcasses. Results showed that the modified universal plastic goniometer can be used to obtain accurate results for elbow flexion and extension and for carpal flexion with good to excellent reliability compared to measurements collected from radiographic assessment. Measurements obtained using an electrogoniometer were less accurate and less reliable than those obtained with a plastic goniometer, possibly because of the size and configuration of the model used. Comparison of measurements from live animals and carcasses revealed no significant differences between mean measurements and suggested that further evaluation of carcasses as a model for study of goniometry measurements in avian wing joints should be considered.

KW - Avian

KW - Barred owl

KW - Electrogoniometry

KW - Goniometry

KW - Joint Angle

KW - Range of motion

KW - Strix varia

UR - http://www.scopus.com/inward/record.url?scp=85065529423&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065529423&partnerID=8YFLogxK

U2 - 10.1647/2017-311

DO - 10.1647/2017-311

M3 - Article

VL - 32

SP - 267

EP - 278

JO - Journal of Avian Medicine and Surgery

JF - Journal of Avian Medicine and Surgery

SN - 1082-6742

IS - 4

ER -