Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners

Simon R Cherry, M. Dahlbom, E. J. Hoffman

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

A fully 3D reconstruction algorithm based on filtered backprojection was evaluated for the reconstruction of data obtained with multi-slice positron emission tomography (PET) scanners which have had the septa removed. This algorithm uses forward-projection through the reconstructed images of a 2D subset of the data to complete the 3D dataset thus satisfying the condition of shift invariance. This is followed by 3D filtered backprojection. Axial sampling was doubled by combining adjacent polar angles, thus improving reconstructed axial resolution. The algorithm was tested using real and simulated datasets and gave high quality reconstructions without artifacts over a wide range of imaging conditions. Events are placed accurately throughout the imaging volume as determined by measurements with a MRI/PET registration phantom. The forward-projection step leads to degradation in image resolution due to insufficient axial and transaxial sampling. This effect is amplified if multiple iterations of the algorithm are used, with little decrease in image noise. Changing the filter employed in the initial 2D reconstruction can be used to alter the noise and resolution characteristics of the 3D images.

Original languageEnglish (US)
Article number020
Pages (from-to)779-790
Number of pages12
JournalPhysics in Medicine and Biology
Volume37
Issue number3
DOIs
StatePublished - 1992

Fingerprint

Positron emission tomography
Positron-Emission Tomography
scanners
positrons
tomography
evaluation
projection
sampling
Sampling
Imaging techniques
septum
image resolution
Image resolution
Invariance
Magnetic resonance imaging
Artifacts
set theory
iteration
Noise
artifacts

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging
  • Physics and Astronomy (miscellaneous)
  • Biomedical Engineering

Cite this

Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners. / Cherry, Simon R; Dahlbom, M.; Hoffman, E. J.

In: Physics in Medicine and Biology, Vol. 37, No. 3, 020, 1992, p. 779-790.

Research output: Contribution to journalArticle

@article{d475d74293f64f01a428fbf2174768a1,
title = "Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners",
abstract = "A fully 3D reconstruction algorithm based on filtered backprojection was evaluated for the reconstruction of data obtained with multi-slice positron emission tomography (PET) scanners which have had the septa removed. This algorithm uses forward-projection through the reconstructed images of a 2D subset of the data to complete the 3D dataset thus satisfying the condition of shift invariance. This is followed by 3D filtered backprojection. Axial sampling was doubled by combining adjacent polar angles, thus improving reconstructed axial resolution. The algorithm was tested using real and simulated datasets and gave high quality reconstructions without artifacts over a wide range of imaging conditions. Events are placed accurately throughout the imaging volume as determined by measurements with a MRI/PET registration phantom. The forward-projection step leads to degradation in image resolution due to insufficient axial and transaxial sampling. This effect is amplified if multiple iterations of the algorithm are used, with little decrease in image noise. Changing the filter employed in the initial 2D reconstruction can be used to alter the noise and resolution characteristics of the 3D images.",
author = "Cherry, {Simon R} and M. Dahlbom and Hoffman, {E. J.}",
year = "1992",
doi = "10.1088/0031-9155/37/3/020",
language = "English (US)",
volume = "37",
pages = "779--790",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Evaluation of a 3D reconstruction algorithm for multi-slice PET scanners

AU - Cherry, Simon R

AU - Dahlbom, M.

AU - Hoffman, E. J.

PY - 1992

Y1 - 1992

N2 - A fully 3D reconstruction algorithm based on filtered backprojection was evaluated for the reconstruction of data obtained with multi-slice positron emission tomography (PET) scanners which have had the septa removed. This algorithm uses forward-projection through the reconstructed images of a 2D subset of the data to complete the 3D dataset thus satisfying the condition of shift invariance. This is followed by 3D filtered backprojection. Axial sampling was doubled by combining adjacent polar angles, thus improving reconstructed axial resolution. The algorithm was tested using real and simulated datasets and gave high quality reconstructions without artifacts over a wide range of imaging conditions. Events are placed accurately throughout the imaging volume as determined by measurements with a MRI/PET registration phantom. The forward-projection step leads to degradation in image resolution due to insufficient axial and transaxial sampling. This effect is amplified if multiple iterations of the algorithm are used, with little decrease in image noise. Changing the filter employed in the initial 2D reconstruction can be used to alter the noise and resolution characteristics of the 3D images.

AB - A fully 3D reconstruction algorithm based on filtered backprojection was evaluated for the reconstruction of data obtained with multi-slice positron emission tomography (PET) scanners which have had the septa removed. This algorithm uses forward-projection through the reconstructed images of a 2D subset of the data to complete the 3D dataset thus satisfying the condition of shift invariance. This is followed by 3D filtered backprojection. Axial sampling was doubled by combining adjacent polar angles, thus improving reconstructed axial resolution. The algorithm was tested using real and simulated datasets and gave high quality reconstructions without artifacts over a wide range of imaging conditions. Events are placed accurately throughout the imaging volume as determined by measurements with a MRI/PET registration phantom. The forward-projection step leads to degradation in image resolution due to insufficient axial and transaxial sampling. This effect is amplified if multiple iterations of the algorithm are used, with little decrease in image noise. Changing the filter employed in the initial 2D reconstruction can be used to alter the noise and resolution characteristics of the 3D images.

UR - http://www.scopus.com/inward/record.url?scp=0026582130&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026582130&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/37/3/020

DO - 10.1088/0031-9155/37/3/020

M3 - Article

VL - 37

SP - 779

EP - 790

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 3

M1 - 020

ER -