In vitro degradation studies of devices fabricated from polylactic acid (PLA) and polyglycolic acid (PGA) are usually performed at the physiologic 37°C and often take long periods of time to complete. The objective of the present study was to examine the degradation of a 50:50 PLA-PGA copolymer over a wide temperature range (25°C to 80°C) and compare the degradation characteristics at temperatures below and above the polymer's glass transition temperature (T(g)). Samples were fabricated using a solvent- casting technique and subjected to degradation in phosphate-buffered saline at the different test temperatures (T) for different periods of time. At the end of each test period, the samples were examined for changes in mass and molecular weight. The pH of the degradation media was also measured. Using the Arrhenius equation, activation energies were calculated for the degradation reaction. The results indicated that the rates of change of mass and molecular weight increased with increasing test temperatures. Activation energies for the degradation reaction at temperatures below and above the T(g) were distinctly different. Thus, it is recommended that tests performed at T > T(g) should not be used to predict degradation behavior at T < T(g).

Original languageEnglish (US)
Pages (from-to)345-352
Number of pages8
JournalTissue Engineering
Volume3
Issue number4
DOIs
StatePublished - 1997
Externally publishedYes

Fingerprint

Copolymers
Degradation
Temperature
Acids
Molecular Weight
Polyglycolic Acid
Transition Temperature
Activation energy
Molecular weight
Glass
Polymers
Phosphates
polylactic acid-polyglycolic acid copolymer
Equipment and Supplies
Casting

ASJC Scopus subject areas

  • Biophysics
  • Cell Biology

Cite this

Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997). Elevated temperature degradation of a 50: 50 copolymer of PLA-PGA. Tissue Engineering, 3(4), 345-352. https://doi.org/10.1089/ten.1997.3.345

Elevated temperature degradation of a 50 : 50 copolymer of PLA-PGA. / Agrawal, C. Mauli; Huang, D.; Schmitz, J. P.; Athanasiou, K. A.

In: Tissue Engineering, Vol. 3, No. 4, 1997, p. 345-352.

Research output: Contribution to journalArticle

Agrawal, CM, Huang, D, Schmitz, JP & Athanasiou, KA 1997, 'Elevated temperature degradation of a 50: 50 copolymer of PLA-PGA', Tissue Engineering, vol. 3, no. 4, pp. 345-352. https://doi.org/10.1089/ten.1997.3.345
Agrawal, C. Mauli ; Huang, D. ; Schmitz, J. P. ; Athanasiou, K. A. / Elevated temperature degradation of a 50 : 50 copolymer of PLA-PGA. In: Tissue Engineering. 1997 ; Vol. 3, No. 4. pp. 345-352.
@article{dc850548eb58478e9695ee86856f1d9b,
title = "Elevated temperature degradation of a 50: 50 copolymer of PLA-PGA",
abstract = "In vitro degradation studies of devices fabricated from polylactic acid (PLA) and polyglycolic acid (PGA) are usually performed at the physiologic 37°C and often take long periods of time to complete. The objective of the present study was to examine the degradation of a 50:50 PLA-PGA copolymer over a wide temperature range (25°C to 80°C) and compare the degradation characteristics at temperatures below and above the polymer's glass transition temperature (T(g)). Samples were fabricated using a solvent- casting technique and subjected to degradation in phosphate-buffered saline at the different test temperatures (T) for different periods of time. At the end of each test period, the samples were examined for changes in mass and molecular weight. The pH of the degradation media was also measured. Using the Arrhenius equation, activation energies were calculated for the degradation reaction. The results indicated that the rates of change of mass and molecular weight increased with increasing test temperatures. Activation energies for the degradation reaction at temperatures below and above the T(g) were distinctly different. Thus, it is recommended that tests performed at T > T(g) should not be used to predict degradation behavior at T < T(g).",
author = "Agrawal, {C. Mauli} and D. Huang and Schmitz, {J. P.} and Athanasiou, {K. A.}",
year = "1997",
doi = "10.1089/ten.1997.3.345",
language = "English (US)",
volume = "3",
pages = "345--352",
journal = "Tissue Engineering",
issn = "1076-3279",
publisher = "Mary Ann Liebert Inc.",
number = "4",

}

TY - JOUR

T1 - Elevated temperature degradation of a 50

T2 - 50 copolymer of PLA-PGA

AU - Agrawal, C. Mauli

AU - Huang, D.

AU - Schmitz, J. P.

AU - Athanasiou, K. A.

PY - 1997

Y1 - 1997

N2 - In vitro degradation studies of devices fabricated from polylactic acid (PLA) and polyglycolic acid (PGA) are usually performed at the physiologic 37°C and often take long periods of time to complete. The objective of the present study was to examine the degradation of a 50:50 PLA-PGA copolymer over a wide temperature range (25°C to 80°C) and compare the degradation characteristics at temperatures below and above the polymer's glass transition temperature (T(g)). Samples were fabricated using a solvent- casting technique and subjected to degradation in phosphate-buffered saline at the different test temperatures (T) for different periods of time. At the end of each test period, the samples were examined for changes in mass and molecular weight. The pH of the degradation media was also measured. Using the Arrhenius equation, activation energies were calculated for the degradation reaction. The results indicated that the rates of change of mass and molecular weight increased with increasing test temperatures. Activation energies for the degradation reaction at temperatures below and above the T(g) were distinctly different. Thus, it is recommended that tests performed at T > T(g) should not be used to predict degradation behavior at T < T(g).

AB - In vitro degradation studies of devices fabricated from polylactic acid (PLA) and polyglycolic acid (PGA) are usually performed at the physiologic 37°C and often take long periods of time to complete. The objective of the present study was to examine the degradation of a 50:50 PLA-PGA copolymer over a wide temperature range (25°C to 80°C) and compare the degradation characteristics at temperatures below and above the polymer's glass transition temperature (T(g)). Samples were fabricated using a solvent- casting technique and subjected to degradation in phosphate-buffered saline at the different test temperatures (T) for different periods of time. At the end of each test period, the samples were examined for changes in mass and molecular weight. The pH of the degradation media was also measured. Using the Arrhenius equation, activation energies were calculated for the degradation reaction. The results indicated that the rates of change of mass and molecular weight increased with increasing test temperatures. Activation energies for the degradation reaction at temperatures below and above the T(g) were distinctly different. Thus, it is recommended that tests performed at T > T(g) should not be used to predict degradation behavior at T < T(g).

UR - http://www.scopus.com/inward/record.url?scp=0031471499&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031471499&partnerID=8YFLogxK

U2 - 10.1089/ten.1997.3.345

DO - 10.1089/ten.1997.3.345

M3 - Article

VL - 3

SP - 345

EP - 352

JO - Tissue Engineering

JF - Tissue Engineering

SN - 1076-3279

IS - 4

ER -