Efficient array design for sonotherapy enhanced drug delivery

Douglas N. Stephens, Dustin E. Kruse, Stephen Barnes, Thomas Clary, X. Ming Lu, Levin Nock, Katherine Ferrara

Research output: Chapter in Book/Report/Conference proceedingConference contribution

4 Citations (Scopus)

Abstract

Activated delivery of drug-encapsulated vehicles to target sites in the body can be implemented with the use of drug-carrying thermally-sensitive liposomes which can release their contents at specifically identified sites. We have designed an array to initiate a site-targeted liposome drug release through a controlled local rise in tissue temperature by a few degrees. A high performance multi-row array which can simultaneously both image and treat a tumor site has been proposed; here we describe the use of this array for thermal treatment. In this application, the heat is supplied by an efficient ultrasound array to release the liposome carrying drug payload directly to the tumor site. A multi-frequency compound array has been constructed and tested in a linear multi-row array construction. The high performance imaging center row is made of 128 elements at 1.1 lambda pitch operating at 5.24MHz with a -6dB fractional bandwidth of 73%; the two outer rows, one on each side of the center row and hard wired together in a 1.5D format, are made of 64 elements each. The two outer rows in the initial design operate at 1.48MHz and a -6dB fractional bandwidth of 54% with a 0.67 lambda pitch. To operate the outer rows in a sonotherapy mode, the array, cable and probe electrical interface to the system were optimized to achieve high efficiency tissue heating. To select the most efficient narrow band transmit frequency, our KLM model was used to predict the best ratio of spectral estimates of the array effective electrical load resistances that determine the acoustic radiated power and dissipative losses. Thermal models were also used in various modes of operation to predict critical internal array temperatures where practical measurements are challenging. Delivery of 10 Watts of average acoustic power is desired for relatively long periods, to be directed to a 1 square centimeter area at depths in the range of 20 to 50 mm in order to raise the tissue temperature by several degrees. The overall transmission efficiency of the original commercial high bandwidth imaging design is 20%, the new design is 40% efficient. Our KLM transmission model was used to predict a marked overall improvement of double this efficiency while using an unmodified Siemens Antares imaging system. The operational result is a probe-based improved efficiency acoustic power delivery system for sonotherapy enhanced targeted drug release that maintains internal array temperatures at less than 60C.

Original languageEnglish (US)
Title of host publicationProceedings - IEEE Ultrasonics Symposium
Pages108-111
Number of pages4
DOIs
StatePublished - 2007
Event2007 IEEE Ultrasonics Symposium, IUS - New York, NY, United States
Duration: Oct 28 2007Oct 31 2007

Other

Other2007 IEEE Ultrasonics Symposium, IUS
CountryUnited States
CityNew York, NY
Period10/28/0710/31/07

Fingerprint

Drug delivery
Liposomes
Acoustics
Tissue
Bandwidth
Tumors
Imaging techniques
Temperature
Imaging systems
Frequency bands
Cables
Ultrasonics
Heat treatment
Heating
Hot Temperature

Keywords

  • Array
  • Drug delivery
  • Liposome
  • Multifrequency

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Stephens, D. N., Kruse, D. E., Barnes, S., Clary, T., Lu, X. M., Nock, L., & Ferrara, K. (2007). Efficient array design for sonotherapy enhanced drug delivery. In Proceedings - IEEE Ultrasonics Symposium (pp. 108-111). [4409613] https://doi.org/10.1109/ULTSYM.2007.40

Efficient array design for sonotherapy enhanced drug delivery. / Stephens, Douglas N.; Kruse, Dustin E.; Barnes, Stephen; Clary, Thomas; Lu, X. Ming; Nock, Levin; Ferrara, Katherine.

Proceedings - IEEE Ultrasonics Symposium. 2007. p. 108-111 4409613.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Stephens, DN, Kruse, DE, Barnes, S, Clary, T, Lu, XM, Nock, L & Ferrara, K 2007, Efficient array design for sonotherapy enhanced drug delivery. in Proceedings - IEEE Ultrasonics Symposium., 4409613, pp. 108-111, 2007 IEEE Ultrasonics Symposium, IUS, New York, NY, United States, 10/28/07. https://doi.org/10.1109/ULTSYM.2007.40
Stephens DN, Kruse DE, Barnes S, Clary T, Lu XM, Nock L et al. Efficient array design for sonotherapy enhanced drug delivery. In Proceedings - IEEE Ultrasonics Symposium. 2007. p. 108-111. 4409613 https://doi.org/10.1109/ULTSYM.2007.40
Stephens, Douglas N. ; Kruse, Dustin E. ; Barnes, Stephen ; Clary, Thomas ; Lu, X. Ming ; Nock, Levin ; Ferrara, Katherine. / Efficient array design for sonotherapy enhanced drug delivery. Proceedings - IEEE Ultrasonics Symposium. 2007. pp. 108-111
@inproceedings{925e0d7e7c4642afb432547404c16d4f,
title = "Efficient array design for sonotherapy enhanced drug delivery",
abstract = "Activated delivery of drug-encapsulated vehicles to target sites in the body can be implemented with the use of drug-carrying thermally-sensitive liposomes which can release their contents at specifically identified sites. We have designed an array to initiate a site-targeted liposome drug release through a controlled local rise in tissue temperature by a few degrees. A high performance multi-row array which can simultaneously both image and treat a tumor site has been proposed; here we describe the use of this array for thermal treatment. In this application, the heat is supplied by an efficient ultrasound array to release the liposome carrying drug payload directly to the tumor site. A multi-frequency compound array has been constructed and tested in a linear multi-row array construction. The high performance imaging center row is made of 128 elements at 1.1 lambda pitch operating at 5.24MHz with a -6dB fractional bandwidth of 73{\%}; the two outer rows, one on each side of the center row and hard wired together in a 1.5D format, are made of 64 elements each. The two outer rows in the initial design operate at 1.48MHz and a -6dB fractional bandwidth of 54{\%} with a 0.67 lambda pitch. To operate the outer rows in a sonotherapy mode, the array, cable and probe electrical interface to the system were optimized to achieve high efficiency tissue heating. To select the most efficient narrow band transmit frequency, our KLM model was used to predict the best ratio of spectral estimates of the array effective electrical load resistances that determine the acoustic radiated power and dissipative losses. Thermal models were also used in various modes of operation to predict critical internal array temperatures where practical measurements are challenging. Delivery of 10 Watts of average acoustic power is desired for relatively long periods, to be directed to a 1 square centimeter area at depths in the range of 20 to 50 mm in order to raise the tissue temperature by several degrees. The overall transmission efficiency of the original commercial high bandwidth imaging design is 20{\%}, the new design is 40{\%} efficient. Our KLM transmission model was used to predict a marked overall improvement of double this efficiency while using an unmodified Siemens Antares imaging system. The operational result is a probe-based improved efficiency acoustic power delivery system for sonotherapy enhanced targeted drug release that maintains internal array temperatures at less than 60C.",
keywords = "Array, Drug delivery, Liposome, Multifrequency",
author = "Stephens, {Douglas N.} and Kruse, {Dustin E.} and Stephen Barnes and Thomas Clary and Lu, {X. Ming} and Levin Nock and Katherine Ferrara",
year = "2007",
doi = "10.1109/ULTSYM.2007.40",
language = "English (US)",
isbn = "1424413834",
pages = "108--111",
booktitle = "Proceedings - IEEE Ultrasonics Symposium",

}

TY - GEN

T1 - Efficient array design for sonotherapy enhanced drug delivery

AU - Stephens, Douglas N.

AU - Kruse, Dustin E.

AU - Barnes, Stephen

AU - Clary, Thomas

AU - Lu, X. Ming

AU - Nock, Levin

AU - Ferrara, Katherine

PY - 2007

Y1 - 2007

N2 - Activated delivery of drug-encapsulated vehicles to target sites in the body can be implemented with the use of drug-carrying thermally-sensitive liposomes which can release their contents at specifically identified sites. We have designed an array to initiate a site-targeted liposome drug release through a controlled local rise in tissue temperature by a few degrees. A high performance multi-row array which can simultaneously both image and treat a tumor site has been proposed; here we describe the use of this array for thermal treatment. In this application, the heat is supplied by an efficient ultrasound array to release the liposome carrying drug payload directly to the tumor site. A multi-frequency compound array has been constructed and tested in a linear multi-row array construction. The high performance imaging center row is made of 128 elements at 1.1 lambda pitch operating at 5.24MHz with a -6dB fractional bandwidth of 73%; the two outer rows, one on each side of the center row and hard wired together in a 1.5D format, are made of 64 elements each. The two outer rows in the initial design operate at 1.48MHz and a -6dB fractional bandwidth of 54% with a 0.67 lambda pitch. To operate the outer rows in a sonotherapy mode, the array, cable and probe electrical interface to the system were optimized to achieve high efficiency tissue heating. To select the most efficient narrow band transmit frequency, our KLM model was used to predict the best ratio of spectral estimates of the array effective electrical load resistances that determine the acoustic radiated power and dissipative losses. Thermal models were also used in various modes of operation to predict critical internal array temperatures where practical measurements are challenging. Delivery of 10 Watts of average acoustic power is desired for relatively long periods, to be directed to a 1 square centimeter area at depths in the range of 20 to 50 mm in order to raise the tissue temperature by several degrees. The overall transmission efficiency of the original commercial high bandwidth imaging design is 20%, the new design is 40% efficient. Our KLM transmission model was used to predict a marked overall improvement of double this efficiency while using an unmodified Siemens Antares imaging system. The operational result is a probe-based improved efficiency acoustic power delivery system for sonotherapy enhanced targeted drug release that maintains internal array temperatures at less than 60C.

AB - Activated delivery of drug-encapsulated vehicles to target sites in the body can be implemented with the use of drug-carrying thermally-sensitive liposomes which can release their contents at specifically identified sites. We have designed an array to initiate a site-targeted liposome drug release through a controlled local rise in tissue temperature by a few degrees. A high performance multi-row array which can simultaneously both image and treat a tumor site has been proposed; here we describe the use of this array for thermal treatment. In this application, the heat is supplied by an efficient ultrasound array to release the liposome carrying drug payload directly to the tumor site. A multi-frequency compound array has been constructed and tested in a linear multi-row array construction. The high performance imaging center row is made of 128 elements at 1.1 lambda pitch operating at 5.24MHz with a -6dB fractional bandwidth of 73%; the two outer rows, one on each side of the center row and hard wired together in a 1.5D format, are made of 64 elements each. The two outer rows in the initial design operate at 1.48MHz and a -6dB fractional bandwidth of 54% with a 0.67 lambda pitch. To operate the outer rows in a sonotherapy mode, the array, cable and probe electrical interface to the system were optimized to achieve high efficiency tissue heating. To select the most efficient narrow band transmit frequency, our KLM model was used to predict the best ratio of spectral estimates of the array effective electrical load resistances that determine the acoustic radiated power and dissipative losses. Thermal models were also used in various modes of operation to predict critical internal array temperatures where practical measurements are challenging. Delivery of 10 Watts of average acoustic power is desired for relatively long periods, to be directed to a 1 square centimeter area at depths in the range of 20 to 50 mm in order to raise the tissue temperature by several degrees. The overall transmission efficiency of the original commercial high bandwidth imaging design is 20%, the new design is 40% efficient. Our KLM transmission model was used to predict a marked overall improvement of double this efficiency while using an unmodified Siemens Antares imaging system. The operational result is a probe-based improved efficiency acoustic power delivery system for sonotherapy enhanced targeted drug release that maintains internal array temperatures at less than 60C.

KW - Array

KW - Drug delivery

KW - Liposome

KW - Multifrequency

UR - http://www.scopus.com/inward/record.url?scp=48149100080&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=48149100080&partnerID=8YFLogxK

U2 - 10.1109/ULTSYM.2007.40

DO - 10.1109/ULTSYM.2007.40

M3 - Conference contribution

AN - SCOPUS:48149100080

SN - 1424413834

SN - 9781424413836

SP - 108

EP - 111

BT - Proceedings - IEEE Ultrasonics Symposium

ER -