Effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis

X. Neil Dong, Yener N. Yeni, Clifford M. Les, David P Fyhrie

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The viscoelastic properties of cancellous bone can be measured nondestructively in compression testing using a dynamic mechanical analyzer. In this study, we examined the effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis. During dynamic compression testing, the cancellous bone specimens may be mechanically fixed (e.g., glued) to the loading platens or they may be free to expand across the platen surface. When specimens of cancellous bone were tested between platens with gluing, the dependence of loss tangent on frequency was not consistent with previously observed strain-rate-dependent mechanical behavior of cancellous bone. When long specimens of cancellous bone (length = 10 mm, diameter = 8 mm) were tested without gluing, the relationship between loss tangent and frequency depended on the level of load applied. For short specimens (length = 5 mm, diameter = 8 mm) tested without gluing, however, the frequency dependence of loss tangent agreed with existing data reported for the strain-rate-dependent behavior of cancellous bone and also with the frequency dependence of cortical bone viscoelasticity. Therefore, we recommend that short cancellous bone cylinders with a length of 5 mm and a diameter of 8 mm should be used without gluing in the dynamic mechanical analysis of cancellous bone. This is consistent with the American Society for Testing and Materials testing recommendations for plastics, but different from current practice for unimodal mechanical testing of cancellous bone.

Original languageEnglish (US)
Pages (from-to)573-583
Number of pages11
JournalJournal of Biomedical Materials Research - Part A
Volume68
Issue number3
StatePublished - Feb 1 2004
Externally publishedYes

Fingerprint

Dynamic mechanical analysis
Bone
Boundary conditions
Geometry
Gluing
Compression testing
Strain rate
Materials testing
Mechanical testing
Viscoelasticity
Plastics

Keywords

  • Cancellous bone
  • Dynamic mechanical analysis
  • Loss tangent
  • Storage modulus
  • Viscoelasticity

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

Effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis. / Dong, X. Neil; Yeni, Yener N.; Les, Clifford M.; Fyhrie, David P.

In: Journal of Biomedical Materials Research - Part A, Vol. 68, No. 3, 01.02.2004, p. 573-583.

Research output: Contribution to journalArticle

@article{22ee50a7914c46aa813bbc1a99f77b57,
title = "Effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis",
abstract = "The viscoelastic properties of cancellous bone can be measured nondestructively in compression testing using a dynamic mechanical analyzer. In this study, we examined the effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis. During dynamic compression testing, the cancellous bone specimens may be mechanically fixed (e.g., glued) to the loading platens or they may be free to expand across the platen surface. When specimens of cancellous bone were tested between platens with gluing, the dependence of loss tangent on frequency was not consistent with previously observed strain-rate-dependent mechanical behavior of cancellous bone. When long specimens of cancellous bone (length = 10 mm, diameter = 8 mm) were tested without gluing, the relationship between loss tangent and frequency depended on the level of load applied. For short specimens (length = 5 mm, diameter = 8 mm) tested without gluing, however, the frequency dependence of loss tangent agreed with existing data reported for the strain-rate-dependent behavior of cancellous bone and also with the frequency dependence of cortical bone viscoelasticity. Therefore, we recommend that short cancellous bone cylinders with a length of 5 mm and a diameter of 8 mm should be used without gluing in the dynamic mechanical analysis of cancellous bone. This is consistent with the American Society for Testing and Materials testing recommendations for plastics, but different from current practice for unimodal mechanical testing of cancellous bone.",
keywords = "Cancellous bone, Dynamic mechanical analysis, Loss tangent, Storage modulus, Viscoelasticity",
author = "Dong, {X. Neil} and Yeni, {Yener N.} and Les, {Clifford M.} and Fyhrie, {David P}",
year = "2004",
month = "2",
day = "1",
language = "English (US)",
volume = "68",
pages = "573--583",
journal = "Journal of Biomedical Materials Research - Part A",
issn = "1549-3296",
publisher = "Heterocorporation",
number = "3",

}

TY - JOUR

T1 - Effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis

AU - Dong, X. Neil

AU - Yeni, Yener N.

AU - Les, Clifford M.

AU - Fyhrie, David P

PY - 2004/2/1

Y1 - 2004/2/1

N2 - The viscoelastic properties of cancellous bone can be measured nondestructively in compression testing using a dynamic mechanical analyzer. In this study, we examined the effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis. During dynamic compression testing, the cancellous bone specimens may be mechanically fixed (e.g., glued) to the loading platens or they may be free to expand across the platen surface. When specimens of cancellous bone were tested between platens with gluing, the dependence of loss tangent on frequency was not consistent with previously observed strain-rate-dependent mechanical behavior of cancellous bone. When long specimens of cancellous bone (length = 10 mm, diameter = 8 mm) were tested without gluing, the relationship between loss tangent and frequency depended on the level of load applied. For short specimens (length = 5 mm, diameter = 8 mm) tested without gluing, however, the frequency dependence of loss tangent agreed with existing data reported for the strain-rate-dependent behavior of cancellous bone and also with the frequency dependence of cortical bone viscoelasticity. Therefore, we recommend that short cancellous bone cylinders with a length of 5 mm and a diameter of 8 mm should be used without gluing in the dynamic mechanical analysis of cancellous bone. This is consistent with the American Society for Testing and Materials testing recommendations for plastics, but different from current practice for unimodal mechanical testing of cancellous bone.

AB - The viscoelastic properties of cancellous bone can be measured nondestructively in compression testing using a dynamic mechanical analyzer. In this study, we examined the effects of end boundary conditions and specimen geometry on the viscoelastic properties of cancellous bone measured by dynamic mechanical analysis. During dynamic compression testing, the cancellous bone specimens may be mechanically fixed (e.g., glued) to the loading platens or they may be free to expand across the platen surface. When specimens of cancellous bone were tested between platens with gluing, the dependence of loss tangent on frequency was not consistent with previously observed strain-rate-dependent mechanical behavior of cancellous bone. When long specimens of cancellous bone (length = 10 mm, diameter = 8 mm) were tested without gluing, the relationship between loss tangent and frequency depended on the level of load applied. For short specimens (length = 5 mm, diameter = 8 mm) tested without gluing, however, the frequency dependence of loss tangent agreed with existing data reported for the strain-rate-dependent behavior of cancellous bone and also with the frequency dependence of cortical bone viscoelasticity. Therefore, we recommend that short cancellous bone cylinders with a length of 5 mm and a diameter of 8 mm should be used without gluing in the dynamic mechanical analysis of cancellous bone. This is consistent with the American Society for Testing and Materials testing recommendations for plastics, but different from current practice for unimodal mechanical testing of cancellous bone.

KW - Cancellous bone

KW - Dynamic mechanical analysis

KW - Loss tangent

KW - Storage modulus

KW - Viscoelasticity

UR - http://www.scopus.com/inward/record.url?scp=1342280527&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1342280527&partnerID=8YFLogxK

M3 - Article

C2 - 14762938

AN - SCOPUS:1342280527

VL - 68

SP - 573

EP - 583

JO - Journal of Biomedical Materials Research - Part A

JF - Journal of Biomedical Materials Research - Part A

SN - 1549-3296

IS - 3

ER -