Effect of cataract surgery on contrast sensitivity and glare in patients with 20/50 or better snellen acuity

D. S. Pfoff, John S Werner

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

The effect of cataract surgery was assessed in 103 patients whose visual acuity, as measured in dim light and with high contrast Snellen letters, was 20/50 or better. The patients desired cataract surgery. They complained of glare symptoms, had given up driving at night, or both. Contrast sensitivity was measured under simulated night conditions with a calibrated Vistech MCT 8000 device. No patient who had a contrast sensitivity of less than 27 at 6 cycles per degree (20/70 'equivalent acuity') had cataract surgery. The mean preoperative contrast sensitivity function showed abnormally low values for all frequencies (cycles/degree) tested. Postoperatively the values returned to normal. Of 99 patients who answered a postoperative questionnaire, 41 (41%) had been driving at night preoperatively and 80 (80%) were driving at night postoperatively. A control group of 24 noncataractous patients (48 eyes) was in the normal range of the test device used. These results support the view that the benefits of cataract surgery are not well predicted by Snellen acuity, even though functional vision may be significantly reduced.

Original languageEnglish (US)
Pages (from-to)620-625
Number of pages6
JournalJournal of Cataract and Refractive Surgery
Volume20
Issue number6
StatePublished - 1994
Externally publishedYes

Fingerprint

Glare
Contrast Sensitivity
Cataract
Equipment and Supplies
Visual Acuity
Reference Values
Light
Control Groups

Keywords

  • cataract surgery
  • contrast sensitivity
  • functional vision
  • glare sensitivity
  • glare testing

ASJC Scopus subject areas

  • Ophthalmology

Cite this

@article{462193337e9648ef9836f385991f45bf,
title = "Effect of cataract surgery on contrast sensitivity and glare in patients with 20/50 or better snellen acuity",
abstract = "The effect of cataract surgery was assessed in 103 patients whose visual acuity, as measured in dim light and with high contrast Snellen letters, was 20/50 or better. The patients desired cataract surgery. They complained of glare symptoms, had given up driving at night, or both. Contrast sensitivity was measured under simulated night conditions with a calibrated Vistech MCT 8000 device. No patient who had a contrast sensitivity of less than 27 at 6 cycles per degree (20/70 'equivalent acuity') had cataract surgery. The mean preoperative contrast sensitivity function showed abnormally low values for all frequencies (cycles/degree) tested. Postoperatively the values returned to normal. Of 99 patients who answered a postoperative questionnaire, 41 (41{\%}) had been driving at night preoperatively and 80 (80{\%}) were driving at night postoperatively. A control group of 24 noncataractous patients (48 eyes) was in the normal range of the test device used. These results support the view that the benefits of cataract surgery are not well predicted by Snellen acuity, even though functional vision may be significantly reduced.",
keywords = "cataract surgery, contrast sensitivity, functional vision, glare sensitivity, glare testing",
author = "Pfoff, {D. S.} and Werner, {John S}",
year = "1994",
language = "English (US)",
volume = "20",
pages = "620--625",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "6",

}

TY - JOUR

T1 - Effect of cataract surgery on contrast sensitivity and glare in patients with 20/50 or better snellen acuity

AU - Pfoff, D. S.

AU - Werner, John S

PY - 1994

Y1 - 1994

N2 - The effect of cataract surgery was assessed in 103 patients whose visual acuity, as measured in dim light and with high contrast Snellen letters, was 20/50 or better. The patients desired cataract surgery. They complained of glare symptoms, had given up driving at night, or both. Contrast sensitivity was measured under simulated night conditions with a calibrated Vistech MCT 8000 device. No patient who had a contrast sensitivity of less than 27 at 6 cycles per degree (20/70 'equivalent acuity') had cataract surgery. The mean preoperative contrast sensitivity function showed abnormally low values for all frequencies (cycles/degree) tested. Postoperatively the values returned to normal. Of 99 patients who answered a postoperative questionnaire, 41 (41%) had been driving at night preoperatively and 80 (80%) were driving at night postoperatively. A control group of 24 noncataractous patients (48 eyes) was in the normal range of the test device used. These results support the view that the benefits of cataract surgery are not well predicted by Snellen acuity, even though functional vision may be significantly reduced.

AB - The effect of cataract surgery was assessed in 103 patients whose visual acuity, as measured in dim light and with high contrast Snellen letters, was 20/50 or better. The patients desired cataract surgery. They complained of glare symptoms, had given up driving at night, or both. Contrast sensitivity was measured under simulated night conditions with a calibrated Vistech MCT 8000 device. No patient who had a contrast sensitivity of less than 27 at 6 cycles per degree (20/70 'equivalent acuity') had cataract surgery. The mean preoperative contrast sensitivity function showed abnormally low values for all frequencies (cycles/degree) tested. Postoperatively the values returned to normal. Of 99 patients who answered a postoperative questionnaire, 41 (41%) had been driving at night preoperatively and 80 (80%) were driving at night postoperatively. A control group of 24 noncataractous patients (48 eyes) was in the normal range of the test device used. These results support the view that the benefits of cataract surgery are not well predicted by Snellen acuity, even though functional vision may be significantly reduced.

KW - cataract surgery

KW - contrast sensitivity

KW - functional vision

KW - glare sensitivity

KW - glare testing

UR - http://www.scopus.com/inward/record.url?scp=0028073256&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028073256&partnerID=8YFLogxK

M3 - Article

C2 - 7837072

AN - SCOPUS:0028073256

VL - 20

SP - 620

EP - 625

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 6

ER -