Does measurement of four-limb blood pressures at birth improve detection of aortic arch anomalies?

N. Patankar, N. Fernandes, K. Kumar, Veena Manja, Satyanarayana Lakshminrusimha

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Objective:To determine normal four-extremity blood pressure (BP) in the neonatal intensive care unit (NICU) at birth and the utility of upper (UE) and lower extremity (LE) BP difference to screen for coarctation of the aorta (Co-A) and interrupted the aortic arch (IAA).Study Design:Retrospective study of BP at birth (n=866), and case-control study of Co-A/IAA infants and matched controls (1:2).Result:Although BP increased with gestational age (R 2 =0.3, P<0.0001), the pressure gradient between UE and LE did not change with gestation (P=0.68). Forty-six cases of Co-A/IAA were identified, with 92 controls. Pressure gradient was significantly higher in patients with Co-A/IAA (7.6±14.8 versus 0.4±10 mm Hg, P=0.004). However, there was overlap between cases and controls resulting in low sensitivity (41.3% with ≥10 mm Hg gradient cutoff).Conclusion:Evaluation of UE-LE BP gradient at birth is a poor screening test for Co-A/IAA with low sensitivity. Repeating four-limb BP after ductal closure at 24 to 48 h along with SpO 2 screening for critical congenital heart disease may increase sensitivity.

Original languageEnglish (US)
Pages (from-to)376-380
Number of pages5
JournalJournal of Perinatology
Volume36
Issue number5
DOIs
StatePublished - May 1 2016
Externally publishedYes

Fingerprint

Aortic Coarctation
Thoracic Aorta
Extremities
Parturition
Blood Pressure
Lower Extremity
Pressure
Neonatal Intensive Care Units
Gestational Age
Case-Control Studies
Heart Diseases
Retrospective Studies
Pregnancy

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Obstetrics and Gynecology

Cite this

Does measurement of four-limb blood pressures at birth improve detection of aortic arch anomalies? / Patankar, N.; Fernandes, N.; Kumar, K.; Manja, Veena; Lakshminrusimha, Satyanarayana.

In: Journal of Perinatology, Vol. 36, No. 5, 01.05.2016, p. 376-380.

Research output: Contribution to journalArticle

@article{27a792a5a21546588095a4fd17ffbd0e,
title = "Does measurement of four-limb blood pressures at birth improve detection of aortic arch anomalies?",
abstract = "Objective:To determine normal four-extremity blood pressure (BP) in the neonatal intensive care unit (NICU) at birth and the utility of upper (UE) and lower extremity (LE) BP difference to screen for coarctation of the aorta (Co-A) and interrupted the aortic arch (IAA).Study Design:Retrospective study of BP at birth (n=866), and case-control study of Co-A/IAA infants and matched controls (1:2).Result:Although BP increased with gestational age (R 2 =0.3, P<0.0001), the pressure gradient between UE and LE did not change with gestation (P=0.68). Forty-six cases of Co-A/IAA were identified, with 92 controls. Pressure gradient was significantly higher in patients with Co-A/IAA (7.6±14.8 versus 0.4±10 mm Hg, P=0.004). However, there was overlap between cases and controls resulting in low sensitivity (41.3{\%} with ≥10 mm Hg gradient cutoff).Conclusion:Evaluation of UE-LE BP gradient at birth is a poor screening test for Co-A/IAA with low sensitivity. Repeating four-limb BP after ductal closure at 24 to 48 h along with SpO 2 screening for critical congenital heart disease may increase sensitivity.",
author = "N. Patankar and N. Fernandes and K. Kumar and Veena Manja and Satyanarayana Lakshminrusimha",
year = "2016",
month = "5",
day = "1",
doi = "10.1038/jp.2015.203",
language = "English (US)",
volume = "36",
pages = "376--380",
journal = "Journal of Perinatology",
issn = "0743-8346",
publisher = "Nature Publishing Group",
number = "5",

}

TY - JOUR

T1 - Does measurement of four-limb blood pressures at birth improve detection of aortic arch anomalies?

AU - Patankar, N.

AU - Fernandes, N.

AU - Kumar, K.

AU - Manja, Veena

AU - Lakshminrusimha, Satyanarayana

PY - 2016/5/1

Y1 - 2016/5/1

N2 - Objective:To determine normal four-extremity blood pressure (BP) in the neonatal intensive care unit (NICU) at birth and the utility of upper (UE) and lower extremity (LE) BP difference to screen for coarctation of the aorta (Co-A) and interrupted the aortic arch (IAA).Study Design:Retrospective study of BP at birth (n=866), and case-control study of Co-A/IAA infants and matched controls (1:2).Result:Although BP increased with gestational age (R 2 =0.3, P<0.0001), the pressure gradient between UE and LE did not change with gestation (P=0.68). Forty-six cases of Co-A/IAA were identified, with 92 controls. Pressure gradient was significantly higher in patients with Co-A/IAA (7.6±14.8 versus 0.4±10 mm Hg, P=0.004). However, there was overlap between cases and controls resulting in low sensitivity (41.3% with ≥10 mm Hg gradient cutoff).Conclusion:Evaluation of UE-LE BP gradient at birth is a poor screening test for Co-A/IAA with low sensitivity. Repeating four-limb BP after ductal closure at 24 to 48 h along with SpO 2 screening for critical congenital heart disease may increase sensitivity.

AB - Objective:To determine normal four-extremity blood pressure (BP) in the neonatal intensive care unit (NICU) at birth and the utility of upper (UE) and lower extremity (LE) BP difference to screen for coarctation of the aorta (Co-A) and interrupted the aortic arch (IAA).Study Design:Retrospective study of BP at birth (n=866), and case-control study of Co-A/IAA infants and matched controls (1:2).Result:Although BP increased with gestational age (R 2 =0.3, P<0.0001), the pressure gradient between UE and LE did not change with gestation (P=0.68). Forty-six cases of Co-A/IAA were identified, with 92 controls. Pressure gradient was significantly higher in patients with Co-A/IAA (7.6±14.8 versus 0.4±10 mm Hg, P=0.004). However, there was overlap between cases and controls resulting in low sensitivity (41.3% with ≥10 mm Hg gradient cutoff).Conclusion:Evaluation of UE-LE BP gradient at birth is a poor screening test for Co-A/IAA with low sensitivity. Repeating four-limb BP after ductal closure at 24 to 48 h along with SpO 2 screening for critical congenital heart disease may increase sensitivity.

UR - http://www.scopus.com/inward/record.url?scp=84954348357&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84954348357&partnerID=8YFLogxK

U2 - 10.1038/jp.2015.203

DO - 10.1038/jp.2015.203

M3 - Article

C2 - 26765554

AN - SCOPUS:84954348357

VL - 36

SP - 376

EP - 380

JO - Journal of Perinatology

JF - Journal of Perinatology

SN - 0743-8346

IS - 5

ER -