Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia

Ibnu Rahmadane, Andrea F. Certoma, Grantley R. Peck, Yul Fitria, Jean Payne, Axel Colling, Brian J. Shiell, Gary Beddome, Susanne Wilson, Meng Yu, Chris Morrissy, Wojtek P. Michalski, John Bingham, Ian Gardner, John D. Allen

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller’s stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

Original languageEnglish (US)
Article numbere0006079
JournalPLoS Neglected Tropical Diseases
Volume11
Issue number11
DOIs
StatePublished - Nov 13 2017
Externally publishedYes

Fingerprint

Indonesia
Rabies
Antigens
Coloring Agents
Antibodies
Acetone
Formaldehyde
Post-Exposure Prophylaxis
Costs and Cost Analysis
Brain
Routine Diagnostic Tests
Fluorescence
Sensitivity and Specificity

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Infectious Diseases

Cite this

Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia. / Rahmadane, Ibnu; Certoma, Andrea F.; Peck, Grantley R.; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J.; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P.; Bingham, John; Gardner, Ian; Allen, John D.

In: PLoS Neglected Tropical Diseases, Vol. 11, No. 11, e0006079, 13.11.2017.

Research output: Contribution to journalArticle

Rahmadane, I, Certoma, AF, Peck, GR, Fitria, Y, Payne, J, Colling, A, Shiell, BJ, Beddome, G, Wilson, S, Yu, M, Morrissy, C, Michalski, WP, Bingham, J, Gardner, I & Allen, JD 2017, 'Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia', PLoS Neglected Tropical Diseases, vol. 11, no. 11, e0006079. https://doi.org/10.1371/journal.pntd.0006079
Rahmadane, Ibnu ; Certoma, Andrea F. ; Peck, Grantley R. ; Fitria, Yul ; Payne, Jean ; Colling, Axel ; Shiell, Brian J. ; Beddome, Gary ; Wilson, Susanne ; Yu, Meng ; Morrissy, Chris ; Michalski, Wojtek P. ; Bingham, John ; Gardner, Ian ; Allen, John D. / Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia. In: PLoS Neglected Tropical Diseases. 2017 ; Vol. 11, No. 11.
@article{cecdc98a76e94488b3e02f7fbc615ce9,
title = "Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia",
abstract = "Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller’s stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97{\%}. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.",
author = "Ibnu Rahmadane and Certoma, {Andrea F.} and Peck, {Grantley R.} and Yul Fitria and Jean Payne and Axel Colling and Shiell, {Brian J.} and Gary Beddome and Susanne Wilson and Meng Yu and Chris Morrissy and Michalski, {Wojtek P.} and John Bingham and Ian Gardner and Allen, {John D.}",
year = "2017",
month = "11",
day = "13",
doi = "10.1371/journal.pntd.0006079",
language = "English (US)",
volume = "11",
journal = "PLoS Neglected Tropical Diseases",
issn = "1935-2727",
publisher = "Public Library of Science",
number = "11",

}

TY - JOUR

T1 - Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia

AU - Rahmadane, Ibnu

AU - Certoma, Andrea F.

AU - Peck, Grantley R.

AU - Fitria, Yul

AU - Payne, Jean

AU - Colling, Axel

AU - Shiell, Brian J.

AU - Beddome, Gary

AU - Wilson, Susanne

AU - Yu, Meng

AU - Morrissy, Chris

AU - Michalski, Wojtek P.

AU - Bingham, John

AU - Gardner, Ian

AU - Allen, John D.

PY - 2017/11/13

Y1 - 2017/11/13

N2 - Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller’s stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

AB - Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller’s stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

UR - http://www.scopus.com/inward/record.url?scp=85036636790&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85036636790&partnerID=8YFLogxK

U2 - 10.1371/journal.pntd.0006079

DO - 10.1371/journal.pntd.0006079

M3 - Article

C2 - 29131859

AN - SCOPUS:85036636790

VL - 11

JO - PLoS Neglected Tropical Diseases

JF - PLoS Neglected Tropical Diseases

SN - 1935-2727

IS - 11

M1 - e0006079

ER -