Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials

Fuquan Zhang, Haozhao Zhang, Huihui Zhao, Zhengzhong He, Liting Shi, Yaoyao He, Nan Ju, Yi Rong, Jianfeng Qiu

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

To fabricate an individualized anthropomorphic lung phantom with tissue-equivalent radiation attenuation properties using a cost-effective three-dimensional (3D) printing technique. Based on anonymized human chest CT images, the phantom contained a 3D-printed skin shell, filled with tissue equivalent materials with similar radiation attenuation characteristics. The filling materials were a mixture of CaCO3, MgO, agarose, NaCl, pearl powder and silica gel. The dose calculation accuracy of different treatment planning system (TPS) algorithms was validated and compared with the ion chamber measurements in the phantom, including tumor and surrounding normal tissues. The chest phantom was shown to represent a human’s chest in terms of radiation attenuation property and human anatomy. The Hounsfield unit ranges were −60 to −100, 20 to 60, and 120 to 300 for fat, muscle, and bone, respectively. The actual measured values of the ionization chamber were 213.7 cGy for the tumor, 53.85 cGy for normal lung tissue, and 4.1 cGy for the spinal cord, compared to 214.1, 55.2, and 4.5 cGy, respectively, with use of the Monte Carlo algorithm in TPS. The application of 3D printing in anthropomorphic phantoms can improve personalized medical need and efficiency with reduce costs thus, can be used for radiation dose verification.

Original languageEnglish (US)
Pages (from-to)94-100
Number of pages7
JournalQuantitative Imaging in Medicine and Surgery
Volume9
Issue number1
DOIs
StatePublished - Jan 1 2019

Fingerprint

Radiation
Thorax
Costs and Cost Analysis
Lung
Silica Gel
Powders
Sepharose
Neoplasms
Spinal Cord
Anatomy
Fats
Ions
Efficiency
Bone and Bones
Muscles
Skin
Three Dimensional Printing

Keywords

  • 3D printing
  • Personalized
  • Simulation phantom

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials. / Zhang, Fuquan; Zhang, Haozhao; Zhao, Huihui; He, Zhengzhong; Shi, Liting; He, Yaoyao; Ju, Nan; Rong, Yi; Qiu, Jianfeng.

In: Quantitative Imaging in Medicine and Surgery, Vol. 9, No. 1, 01.01.2019, p. 94-100.

Research output: Contribution to journalArticle

Zhang, Fuquan ; Zhang, Haozhao ; Zhao, Huihui ; He, Zhengzhong ; Shi, Liting ; He, Yaoyao ; Ju, Nan ; Rong, Yi ; Qiu, Jianfeng. / Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials. In: Quantitative Imaging in Medicine and Surgery. 2019 ; Vol. 9, No. 1. pp. 94-100.
@article{4dcdd380db064a248c007ee6338486d7,
title = "Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials",
abstract = "To fabricate an individualized anthropomorphic lung phantom with tissue-equivalent radiation attenuation properties using a cost-effective three-dimensional (3D) printing technique. Based on anonymized human chest CT images, the phantom contained a 3D-printed skin shell, filled with tissue equivalent materials with similar radiation attenuation characteristics. The filling materials were a mixture of CaCO3, MgO, agarose, NaCl, pearl powder and silica gel. The dose calculation accuracy of different treatment planning system (TPS) algorithms was validated and compared with the ion chamber measurements in the phantom, including tumor and surrounding normal tissues. The chest phantom was shown to represent a human’s chest in terms of radiation attenuation property and human anatomy. The Hounsfield unit ranges were −60 to −100, 20 to 60, and 120 to 300 for fat, muscle, and bone, respectively. The actual measured values of the ionization chamber were 213.7 cGy for the tumor, 53.85 cGy for normal lung tissue, and 4.1 cGy for the spinal cord, compared to 214.1, 55.2, and 4.5 cGy, respectively, with use of the Monte Carlo algorithm in TPS. The application of 3D printing in anthropomorphic phantoms can improve personalized medical need and efficiency with reduce costs thus, can be used for radiation dose verification.",
keywords = "3D printing, Personalized, Simulation phantom",
author = "Fuquan Zhang and Haozhao Zhang and Huihui Zhao and Zhengzhong He and Liting Shi and Yaoyao He and Nan Ju and Yi Rong and Jianfeng Qiu",
year = "2019",
month = "1",
day = "1",
doi = "10.21037/qims.2018.08.01",
language = "English (US)",
volume = "9",
pages = "94--100",
journal = "Quantitative Imaging in Medicine and Surgery",
issn = "2223-4292",
publisher = "AME Publishing Company",
number = "1",

}

TY - JOUR

T1 - Design and fabrication of a personalized anthropomorphic phantom using 3D printing and tissue equivalent materials

AU - Zhang, Fuquan

AU - Zhang, Haozhao

AU - Zhao, Huihui

AU - He, Zhengzhong

AU - Shi, Liting

AU - He, Yaoyao

AU - Ju, Nan

AU - Rong, Yi

AU - Qiu, Jianfeng

PY - 2019/1/1

Y1 - 2019/1/1

N2 - To fabricate an individualized anthropomorphic lung phantom with tissue-equivalent radiation attenuation properties using a cost-effective three-dimensional (3D) printing technique. Based on anonymized human chest CT images, the phantom contained a 3D-printed skin shell, filled with tissue equivalent materials with similar radiation attenuation characteristics. The filling materials were a mixture of CaCO3, MgO, agarose, NaCl, pearl powder and silica gel. The dose calculation accuracy of different treatment planning system (TPS) algorithms was validated and compared with the ion chamber measurements in the phantom, including tumor and surrounding normal tissues. The chest phantom was shown to represent a human’s chest in terms of radiation attenuation property and human anatomy. The Hounsfield unit ranges were −60 to −100, 20 to 60, and 120 to 300 for fat, muscle, and bone, respectively. The actual measured values of the ionization chamber were 213.7 cGy for the tumor, 53.85 cGy for normal lung tissue, and 4.1 cGy for the spinal cord, compared to 214.1, 55.2, and 4.5 cGy, respectively, with use of the Monte Carlo algorithm in TPS. The application of 3D printing in anthropomorphic phantoms can improve personalized medical need and efficiency with reduce costs thus, can be used for radiation dose verification.

AB - To fabricate an individualized anthropomorphic lung phantom with tissue-equivalent radiation attenuation properties using a cost-effective three-dimensional (3D) printing technique. Based on anonymized human chest CT images, the phantom contained a 3D-printed skin shell, filled with tissue equivalent materials with similar radiation attenuation characteristics. The filling materials were a mixture of CaCO3, MgO, agarose, NaCl, pearl powder and silica gel. The dose calculation accuracy of different treatment planning system (TPS) algorithms was validated and compared with the ion chamber measurements in the phantom, including tumor and surrounding normal tissues. The chest phantom was shown to represent a human’s chest in terms of radiation attenuation property and human anatomy. The Hounsfield unit ranges were −60 to −100, 20 to 60, and 120 to 300 for fat, muscle, and bone, respectively. The actual measured values of the ionization chamber were 213.7 cGy for the tumor, 53.85 cGy for normal lung tissue, and 4.1 cGy for the spinal cord, compared to 214.1, 55.2, and 4.5 cGy, respectively, with use of the Monte Carlo algorithm in TPS. The application of 3D printing in anthropomorphic phantoms can improve personalized medical need and efficiency with reduce costs thus, can be used for radiation dose verification.

KW - 3D printing

KW - Personalized

KW - Simulation phantom

UR - http://www.scopus.com/inward/record.url?scp=85061203029&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85061203029&partnerID=8YFLogxK

U2 - 10.21037/qims.2018.08.01

DO - 10.21037/qims.2018.08.01

M3 - Article

AN - SCOPUS:85061203029

VL - 9

SP - 94

EP - 100

JO - Quantitative Imaging in Medicine and Surgery

JF - Quantitative Imaging in Medicine and Surgery

SN - 2223-4292

IS - 1

ER -