Cytoindentation for obtaining cell biomechanical properties

Daehwan Shin, Kyriacos Athanasiou

Research output: Contribution to journalArticle

128 Citations (Scopus)

Abstract

A novel biomechanical testing methodology was developed to obtain the intrinsic material properties of an individual cell attached to a rigid substrate. With use of a newly designed cell-indentation apparatus (cytoindenter), displacement-controlled indentation tests were conducted on the surface of individual MG63 cells and the corresponding surface reaction force of each cell was measured. The cells were modeled with a linear elasticity solution of half-space indentation and the linear biphasic theory on the assumption that the viscoelastic behavior of each cell was due to the interaction between the solid cytoskeletal matrix and the cytoplasmic fluid. To obtain the intrinsic material properties (aggregate modulus, Poisson's ratio, and permeability), the data for experimental surface reaction force and deformation were curve-fitted with use of solutions predicted with a linear biphasic finite element code in conjunction with optimization routines. The MG63 osteoblast-like cells had a compressive aggregate modulus of 2.05 ± 0.89 kPa, which is two to three orders of magnitude smaller than that of articular cartilage, six to seven orders smaller than that of compact bone, and quite similar to that of leukocytes. The permeability was 1.18 ± 0.65 (x 10-10) m4/N-s, which is four to six orders of magnitude larger than that of cartilage. The Poisson's ratio was 0.37 ± 0.03. The intrinsic material properties of the individual cell in this study can be useful in precisely quantifying mechanical stimuli acting on cells. This information is also needed for theories attempting to establish mechanotransductional relationships.

Original languageEnglish (US)
Pages (from-to)880-890
Number of pages11
JournalJournal of Orthopaedic Research
Volume17
Issue number6
StatePublished - 1999
Externally publishedYes

Fingerprint

Permeability
Elasticity
Articular Cartilage
Osteoblasts
Cartilage
Leukocytes
Cortical Bone

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Cytoindentation for obtaining cell biomechanical properties. / Shin, Daehwan; Athanasiou, Kyriacos.

In: Journal of Orthopaedic Research, Vol. 17, No. 6, 1999, p. 880-890.

Research output: Contribution to journalArticle

Shin, D & Athanasiou, K 1999, 'Cytoindentation for obtaining cell biomechanical properties', Journal of Orthopaedic Research, vol. 17, no. 6, pp. 880-890.
Shin, Daehwan ; Athanasiou, Kyriacos. / Cytoindentation for obtaining cell biomechanical properties. In: Journal of Orthopaedic Research. 1999 ; Vol. 17, No. 6. pp. 880-890.
@article{11f6863cdd8d4f30bdee421feea2dfc0,
title = "Cytoindentation for obtaining cell biomechanical properties",
abstract = "A novel biomechanical testing methodology was developed to obtain the intrinsic material properties of an individual cell attached to a rigid substrate. With use of a newly designed cell-indentation apparatus (cytoindenter), displacement-controlled indentation tests were conducted on the surface of individual MG63 cells and the corresponding surface reaction force of each cell was measured. The cells were modeled with a linear elasticity solution of half-space indentation and the linear biphasic theory on the assumption that the viscoelastic behavior of each cell was due to the interaction between the solid cytoskeletal matrix and the cytoplasmic fluid. To obtain the intrinsic material properties (aggregate modulus, Poisson's ratio, and permeability), the data for experimental surface reaction force and deformation were curve-fitted with use of solutions predicted with a linear biphasic finite element code in conjunction with optimization routines. The MG63 osteoblast-like cells had a compressive aggregate modulus of 2.05 ± 0.89 kPa, which is two to three orders of magnitude smaller than that of articular cartilage, six to seven orders smaller than that of compact bone, and quite similar to that of leukocytes. The permeability was 1.18 ± 0.65 (x 10-10) m4/N-s, which is four to six orders of magnitude larger than that of cartilage. The Poisson's ratio was 0.37 ± 0.03. The intrinsic material properties of the individual cell in this study can be useful in precisely quantifying mechanical stimuli acting on cells. This information is also needed for theories attempting to establish mechanotransductional relationships.",
author = "Daehwan Shin and Kyriacos Athanasiou",
year = "1999",
language = "English (US)",
volume = "17",
pages = "880--890",
journal = "Journal of Orthopaedic Research",
issn = "0736-0266",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Cytoindentation for obtaining cell biomechanical properties

AU - Shin, Daehwan

AU - Athanasiou, Kyriacos

PY - 1999

Y1 - 1999

N2 - A novel biomechanical testing methodology was developed to obtain the intrinsic material properties of an individual cell attached to a rigid substrate. With use of a newly designed cell-indentation apparatus (cytoindenter), displacement-controlled indentation tests were conducted on the surface of individual MG63 cells and the corresponding surface reaction force of each cell was measured. The cells were modeled with a linear elasticity solution of half-space indentation and the linear biphasic theory on the assumption that the viscoelastic behavior of each cell was due to the interaction between the solid cytoskeletal matrix and the cytoplasmic fluid. To obtain the intrinsic material properties (aggregate modulus, Poisson's ratio, and permeability), the data for experimental surface reaction force and deformation were curve-fitted with use of solutions predicted with a linear biphasic finite element code in conjunction with optimization routines. The MG63 osteoblast-like cells had a compressive aggregate modulus of 2.05 ± 0.89 kPa, which is two to three orders of magnitude smaller than that of articular cartilage, six to seven orders smaller than that of compact bone, and quite similar to that of leukocytes. The permeability was 1.18 ± 0.65 (x 10-10) m4/N-s, which is four to six orders of magnitude larger than that of cartilage. The Poisson's ratio was 0.37 ± 0.03. The intrinsic material properties of the individual cell in this study can be useful in precisely quantifying mechanical stimuli acting on cells. This information is also needed for theories attempting to establish mechanotransductional relationships.

AB - A novel biomechanical testing methodology was developed to obtain the intrinsic material properties of an individual cell attached to a rigid substrate. With use of a newly designed cell-indentation apparatus (cytoindenter), displacement-controlled indentation tests were conducted on the surface of individual MG63 cells and the corresponding surface reaction force of each cell was measured. The cells were modeled with a linear elasticity solution of half-space indentation and the linear biphasic theory on the assumption that the viscoelastic behavior of each cell was due to the interaction between the solid cytoskeletal matrix and the cytoplasmic fluid. To obtain the intrinsic material properties (aggregate modulus, Poisson's ratio, and permeability), the data for experimental surface reaction force and deformation were curve-fitted with use of solutions predicted with a linear biphasic finite element code in conjunction with optimization routines. The MG63 osteoblast-like cells had a compressive aggregate modulus of 2.05 ± 0.89 kPa, which is two to three orders of magnitude smaller than that of articular cartilage, six to seven orders smaller than that of compact bone, and quite similar to that of leukocytes. The permeability was 1.18 ± 0.65 (x 10-10) m4/N-s, which is four to six orders of magnitude larger than that of cartilage. The Poisson's ratio was 0.37 ± 0.03. The intrinsic material properties of the individual cell in this study can be useful in precisely quantifying mechanical stimuli acting on cells. This information is also needed for theories attempting to establish mechanotransductional relationships.

UR - http://www.scopus.com/inward/record.url?scp=0033402884&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033402884&partnerID=8YFLogxK

M3 - Article

C2 - 10632455

AN - SCOPUS:0033402884

VL - 17

SP - 880

EP - 890

JO - Journal of Orthopaedic Research

JF - Journal of Orthopaedic Research

SN - 0736-0266

IS - 6

ER -