Correlation of the standard electrocardiogram and continuous ambulatory monitoring in the detection of ventricular arrhythmias in coronary patients

Louis A. Vismara, Craig Pratt, James E. Price, Richard R. Miller, Ezra A. Amsterdam, Dean T. Mason

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

To evaluate the efficacy of ventricular arrhythmia detection in ambulatory patients with stable coronary artery disease, 101 coronary patients documented by arteriography or remote myocardial infarction underwent concurrent evaluation by 10-hour portable ambulatory ECG monitoring and standard 12-lead electrocardiograms (ECGs) obtained serially over 24 months. Portable ECG recorded premature ventricular contractions (PVCs) in 77 patients: 50% serious PVCs (multifocal, paired, >5/minute, R on T) and 9% patients with ventricular tachycardia. Standard ECG was insensitive (p<.001) in arrhythmia detection both by one tracing (PVC prevalence 17%) obtained within 12 hours of portable ECG or by four serial standard ECGs during the subsequent two weeks (PVC prevalence 18%). Although a total of 1,414 standard ECGs during 24 months recorded PVCs in 49% of patients, serious PVCs were limited (p<.001) to 25% and ventricular tachycardia to 1% of patients. However, ventricular ectopy present by any standard ECG (10 per patient) within three months of ambulatory monitoring was associated with high prevalence of hazardous ectopics by portable ECG (p<.05): serious PVC 92%; ventricular tachycardia 17% patients. Even in patients free of ventricular ectopy by 24-month serial standard ECG, portable ECG detected serious PVCs in 62% and ventricular tachycardia in 6% of patients. Thus stable coronary patients manifested frequent ventricular ectopics by portable ECG which were usually undetected by even multiple serial standard ECGs. Importantly, presence of PVCs by standard ECG was related to increased risk of hazardous ventricular arrhythmias by portable ECG.

Original languageEnglish (US)
Pages (from-to)299-304
Number of pages6
JournalJournal of Electrocardiology
Volume10
Issue number4
DOIs
StatePublished - 1977

Fingerprint

Ambulatory Monitoring
Cardiac Arrhythmias
Electrocardiography
Ventricular Premature Complexes
Ventricular Tachycardia

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Correlation of the standard electrocardiogram and continuous ambulatory monitoring in the detection of ventricular arrhythmias in coronary patients. / Vismara, Louis A.; Pratt, Craig; Price, James E.; Miller, Richard R.; Amsterdam, Ezra A.; Mason, Dean T.

In: Journal of Electrocardiology, Vol. 10, No. 4, 1977, p. 299-304.

Research output: Contribution to journalArticle

Vismara, Louis A. ; Pratt, Craig ; Price, James E. ; Miller, Richard R. ; Amsterdam, Ezra A. ; Mason, Dean T. / Correlation of the standard electrocardiogram and continuous ambulatory monitoring in the detection of ventricular arrhythmias in coronary patients. In: Journal of Electrocardiology. 1977 ; Vol. 10, No. 4. pp. 299-304.
@article{7a4edb4886c3432f895e4ce94e4fdc48,
title = "Correlation of the standard electrocardiogram and continuous ambulatory monitoring in the detection of ventricular arrhythmias in coronary patients",
abstract = "To evaluate the efficacy of ventricular arrhythmia detection in ambulatory patients with stable coronary artery disease, 101 coronary patients documented by arteriography or remote myocardial infarction underwent concurrent evaluation by 10-hour portable ambulatory ECG monitoring and standard 12-lead electrocardiograms (ECGs) obtained serially over 24 months. Portable ECG recorded premature ventricular contractions (PVCs) in 77 patients: 50{\%} serious PVCs (multifocal, paired, >5/minute, R on T) and 9{\%} patients with ventricular tachycardia. Standard ECG was insensitive (p<.001) in arrhythmia detection both by one tracing (PVC prevalence 17{\%}) obtained within 12 hours of portable ECG or by four serial standard ECGs during the subsequent two weeks (PVC prevalence 18{\%}). Although a total of 1,414 standard ECGs during 24 months recorded PVCs in 49{\%} of patients, serious PVCs were limited (p<.001) to 25{\%} and ventricular tachycardia to 1{\%} of patients. However, ventricular ectopy present by any standard ECG (10 per patient) within three months of ambulatory monitoring was associated with high prevalence of hazardous ectopics by portable ECG (p<.05): serious PVC 92{\%}; ventricular tachycardia 17{\%} patients. Even in patients free of ventricular ectopy by 24-month serial standard ECG, portable ECG detected serious PVCs in 62{\%} and ventricular tachycardia in 6{\%} of patients. Thus stable coronary patients manifested frequent ventricular ectopics by portable ECG which were usually undetected by even multiple serial standard ECGs. Importantly, presence of PVCs by standard ECG was related to increased risk of hazardous ventricular arrhythmias by portable ECG.",
author = "Vismara, {Louis A.} and Craig Pratt and Price, {James E.} and Miller, {Richard R.} and Amsterdam, {Ezra A.} and Mason, {Dean T.}",
year = "1977",
doi = "10.1016/S0022-0736(77)80001-0",
language = "English (US)",
volume = "10",
pages = "299--304",
journal = "Journal of Electrocardiology",
issn = "0022-0736",
publisher = "Churchill Livingstone",
number = "4",

}

TY - JOUR

T1 - Correlation of the standard electrocardiogram and continuous ambulatory monitoring in the detection of ventricular arrhythmias in coronary patients

AU - Vismara, Louis A.

AU - Pratt, Craig

AU - Price, James E.

AU - Miller, Richard R.

AU - Amsterdam, Ezra A.

AU - Mason, Dean T.

PY - 1977

Y1 - 1977

N2 - To evaluate the efficacy of ventricular arrhythmia detection in ambulatory patients with stable coronary artery disease, 101 coronary patients documented by arteriography or remote myocardial infarction underwent concurrent evaluation by 10-hour portable ambulatory ECG monitoring and standard 12-lead electrocardiograms (ECGs) obtained serially over 24 months. Portable ECG recorded premature ventricular contractions (PVCs) in 77 patients: 50% serious PVCs (multifocal, paired, >5/minute, R on T) and 9% patients with ventricular tachycardia. Standard ECG was insensitive (p<.001) in arrhythmia detection both by one tracing (PVC prevalence 17%) obtained within 12 hours of portable ECG or by four serial standard ECGs during the subsequent two weeks (PVC prevalence 18%). Although a total of 1,414 standard ECGs during 24 months recorded PVCs in 49% of patients, serious PVCs were limited (p<.001) to 25% and ventricular tachycardia to 1% of patients. However, ventricular ectopy present by any standard ECG (10 per patient) within three months of ambulatory monitoring was associated with high prevalence of hazardous ectopics by portable ECG (p<.05): serious PVC 92%; ventricular tachycardia 17% patients. Even in patients free of ventricular ectopy by 24-month serial standard ECG, portable ECG detected serious PVCs in 62% and ventricular tachycardia in 6% of patients. Thus stable coronary patients manifested frequent ventricular ectopics by portable ECG which were usually undetected by even multiple serial standard ECGs. Importantly, presence of PVCs by standard ECG was related to increased risk of hazardous ventricular arrhythmias by portable ECG.

AB - To evaluate the efficacy of ventricular arrhythmia detection in ambulatory patients with stable coronary artery disease, 101 coronary patients documented by arteriography or remote myocardial infarction underwent concurrent evaluation by 10-hour portable ambulatory ECG monitoring and standard 12-lead electrocardiograms (ECGs) obtained serially over 24 months. Portable ECG recorded premature ventricular contractions (PVCs) in 77 patients: 50% serious PVCs (multifocal, paired, >5/minute, R on T) and 9% patients with ventricular tachycardia. Standard ECG was insensitive (p<.001) in arrhythmia detection both by one tracing (PVC prevalence 17%) obtained within 12 hours of portable ECG or by four serial standard ECGs during the subsequent two weeks (PVC prevalence 18%). Although a total of 1,414 standard ECGs during 24 months recorded PVCs in 49% of patients, serious PVCs were limited (p<.001) to 25% and ventricular tachycardia to 1% of patients. However, ventricular ectopy present by any standard ECG (10 per patient) within three months of ambulatory monitoring was associated with high prevalence of hazardous ectopics by portable ECG (p<.05): serious PVC 92%; ventricular tachycardia 17% patients. Even in patients free of ventricular ectopy by 24-month serial standard ECG, portable ECG detected serious PVCs in 62% and ventricular tachycardia in 6% of patients. Thus stable coronary patients manifested frequent ventricular ectopics by portable ECG which were usually undetected by even multiple serial standard ECGs. Importantly, presence of PVCs by standard ECG was related to increased risk of hazardous ventricular arrhythmias by portable ECG.

UR - http://www.scopus.com/inward/record.url?scp=0017717326&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017717326&partnerID=8YFLogxK

U2 - 10.1016/S0022-0736(77)80001-0

DO - 10.1016/S0022-0736(77)80001-0

M3 - Article

C2 - 915397

AN - SCOPUS:0017717326

VL - 10

SP - 299

EP - 304

JO - Journal of Electrocardiology

JF - Journal of Electrocardiology

SN - 0022-0736

IS - 4

ER -